• Title/Summary/Keyword: Patients' Evaluation

Search Result 5,944, Processing Time 0.04 seconds

Helicobacter pylori reinfection rate by a 13C-urea breath test and endoscopic biopsy tests in Korean children (한국 소아에서 Helicobacter pylori 박멸 후 13C-요소 호기 검사와 내시경적 생검을 이용한 재감염률 연구)

  • Shim, Jeong Ok;Seo, Jeong Kee
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.268-272
    • /
    • 2006
  • Purpose : The reinfection rate of H. pylori reported before $^{13}C$-urea breath test($^{13}C$-UBT) era was higher than that of the post $^{13}C$-UBT era. Children are usually reluctant to receive invasive endoscopic evaluation for the reinfection of H. pylori, particularly when they are asymptomatic. The aim of the study is to discover the reinfection rate by different diagnostic tests, and to find out what causes the difference. Methods : Children confirmed to be eradicated from H. pylori were included in the study. Reinfection was evaluated by endoscopic biopsy based tests(n=34, mean age $11.5{\pm}3.7$ years) and/or a $^{13}C$-UBT(n=38, mean age $10.0{\pm}3.6$ years) at the time of 18 months after eradication. At first visit, H. pylori infection had been diagnosed by positive results from a rapid urease test, Giemsa stain and Warthin-Starry stain and/or a positive culture. Eradication was defined as negative results from all above tests 1-3 months after eradication therapy. Results : Reinfection rate by endoscopic biopsy based tests was 35.3 percent(12/34). All patients had abdominal symptoms(P=0.000). Reinfection rate was 13.2 percent(5/38) by a $^{13}C$-UBT. Reinfection rate was higher in children with abdominal symptoms(P=0.008). There was no evidence that reinfection rate depended on the sex(P=0.694), age(P=0.827), diseases(peptic ulcers vs gastritis, P=0.730) and eradication regimen(P=0.087). Conclusion : Helocibacter pylori reinfection rate in Korean children was 13.2 percent per 18 months by a non-invasive test or $^{13}C$-UBT. Accurate determinations of the reinfection rate in children is affected by the compliance of the diagnostic tests. Non-invasive tests should be considered to investigate the reinfection rate in children.

Evaluating and managing hypertension in children: a survey of Korean cardiologists and nephrologists (소아 고혈압의 평가와 관리 방법; 한국 소아심장 전문의와 소아신장 전문의 설문)

  • Lee, Eun Hee;Yim, Hyung Eun;Jang, Gi Young;Yoo, Kee Hwan;Son, Chang Sung;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.992-997
    • /
    • 2008
  • Purpose : Hypertension (HTN) is no longer an exclusively adult disease; the prevalence of pediatric HTN is increasing. To understand the evaluation and treatment of childhood HTN in Korea, we investigated, via a questionnaire, how hypertensive children are currently assessed and managed by pediatric cardiologists (CA) and nephrologists (NE). Methods : We surveyed 82 pediatric CA and 77 NE, regarding how they manage hypertensive children in Korea. Results : A total 75 replies were received to our questionnaire request (response rate: 47.15%). Routine blood pressure (BP) checks were more frequently performed by NE (CA: 5.7%, NE: 25%, P=0.03), but most respondents (86%) did not check BP routinely. Mercury sphygmomanometers were the most commonly used devices and ambulatory blood pressure monitoring was not frequently used. The goal BP in treated patients was set at the 95th percentile by 61% of respondents. NE used a lower BP goal in hypertensive children with renal disease (CA: 24%, NE: 64%, P=0.004) or DM (CA: 12.5%, NE: 50%, P=0.003). Angiotensin converting enzyme (ACE) inhibitors were the most commonly used agents (mean: 59%); following ACE inhibitors, CA preferred diuretics for hypertensive children with renal disease or cardiovascular disease, and NE preferred calcium channel blockers, regardless of underlying disease. Self-monitoring was the most frequent method for BP monitoring at home. Conclusion : In Korea, BP measurement is not yet a routine examination in treating hypertension. There are some differences in management strategies vis-$\grave{a}$-vis hypertension, between pediatric cardiologists and nephrologists. For the appropriate management and prevention of secondary disease in long-term studies, standard guidelines and education are needed for pediatricians.

Prenatal Diagnosis of the 22q11.2 Duplication Syndrome

  • Lee, Moon-Hee;Park, So-Yeon;Lee, Bom-Yi;Choi, Eun-Young;Kim, Jin-Woo;Park, Ju-Yeon;Lee, Yeon-Woo;Oh, Ah-Rum;Lee, Shin-Young;Yang, Jae-Hyug;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.175-178
    • /
    • 2009
  • The 22q11.2 duplication syndrome is an extremely variable disorder with a phenotype ranging from normal to congenital defects and learning disabilities. Recently, the detection rate of 22q11.2 duplication has been increased by molecular techniques, such as array CGH. In this study, we report a familial case of 22q11.2 duplication detected prenatally. Her first pregnancy was terminated because of 22q11.2 duplication detected incidentally by BAC array CGH. The case was referred due to second pregnancy with same 22q11.2 duplication. We perfomed repeat amniocentesis for karyotype and FISH analysis. Karyotype analysis from amniocytes and parental lymphocytes were normal, while FISH analysis of interphase cells presented a duplication of 22q11.2 in the fetus and phenotypically normal mother. The fetal ultrasound showed grossly normal finding. After genetic counseling about variable phenotype with intrafamilial variability with 50% recurrence rate, the couple decided to continue the pregnancy. The newborn had no apparent congenital abnormalities until 2 weeks after birth. We recommend that family members of patients with a 22q11.2 duplication be tested by the interphase FISH analysis. Also, we point out the importance of genetic counseling and an evaluation of the clinical relevance of diagnostic test results.

  • PDF

Comparison of C-reactive Protein between Capillary and Venous Blood in Children (소아에 있어서 C-반응성 단백의 모세혈 및 정맥혈 검사의 비교평가)

  • Jin, Ji Hoon;Jung, Soo Ho;Hong, Young Jin;Son, Byong Kwan;Kim, Soon Ki
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • Purpose : In evaluation of patients, laboratory results are crucial in determination of a treatment plan. Obtaining venous blood from infants and children is a difficult procedure. Substitution of a capillary blood sample for a venous blood sample has been suggested. However, there are few studies showing mutual correlation between C-reactive protein (CRP) results in capillary and venous blood. This study was designed to determine whether the result of the capillary sample is the same as the result of the venous blood sample. Methods : After informed consent, a pair of venous and fingertip capillary blood samples were simultaneously collected from 100 children. The LC-178CRPTM was used for analysis of capillary blood and the Hitachi 7180 automatic hematology analyzer was used for analysis of venous blood. We compared CRP of both venous and capillary blood samples. Results were analyzed by crosstabulation analysis, simple regression analysis and the Bland Altman Plot method. Results : A close correlation (90.63%) was observed between capillary and venous blood analyzed by crosstabulation analysis. CRP results were similar between the two groups and showed a high coefficient correlation ($\beta$=1.3434, $R^2$=0.9888, P<0.0001) when analyzed by a simple regression model. The average value in venous blood was also higher compared to capillary blood. According to Bland Altman Plot analysis, lab results were measured at a 95% confidence interval. Conclusion : CRP results from capillary blood showed close correlation with venous blood sampling. At present, venous blood sampling is the preferred method. However, due to difficulty in venous blood sampling, capillary sampling could be considered as an alternative technique for use with children.

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

Development of a Occupation-Based Bilateral Upper Extremity Training Protocol in a Medical Setting for Stroke Patients (뇌졸중 환자를 대상으로 한 병원 환경에서의 작업 기반 양측성 상지 훈련 프로토콜 개발)

  • Kim, Sun-Ho;Kim, Jung Ran;Park, Hae Yean;Han, A-Reum;Kim, Jong-Bae;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.9 no.1
    • /
    • pp.24-44
    • /
    • 2020
  • Objective : To develop an occupation-based bilateral upper extremity training protocol that can be effectively applied in a medical setting Methods : The research process using the delphi technique was carried out in 3 stages. The first stage was an open questionnaire development stage, The first draft is prepared through literature review and open questions were developed through preliminary research based on the draft. The second stage was the delphi survey. Based on the responses of the experts obtained through the open Delphi survey, the adequacy of the training protocol was shown on a Likert 5 point scale. The items were edited and deleted, reconstructed by analyzing the mean and standard deviation, stability, convergence degree, consensus, and content validity ratio through the questionnaire. The third step was the completion of the protocol. After discussions between researchers, the finalized protocol contents were reorganized to complete the occupation-based bilateral upper extremity training protocol for medical setting. Results : The final protocol consisted of 9 items across 3 areas in the occupation-based intervention selection domain and 81 items across 4 areas in the bilateral upper extremity training domain, intervention period, and evaluation. Conclusions : This study suggests an evidence-based method that collects the opinions of occupational therapists in order to use occupation-based activities as interventions in a situation that currently sees occupational therapy primarily performed in hospitals. It is also meaningful that the bilateral upper extremity training can be applied effectively in clinical situations by concretely presenting.

Comparative Analysis of Double Bundle and Single Bundle ACL Reconstruction with Tibialis Anterior Allograft (동종건을 이용한 단일다발 및 이중다발 전방십자인대 재건술의 비교 분석)

  • Kim, Deok-Weon;Lee, Kang;Kim, Young-Woo;Yang, Sang-Jin;Seo, Jeong-Gook;Kim, Jin-Goo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.198-204
    • /
    • 2008
  • Purpose: The purpose of this study is to analyze the merits and demerits of double bundle reconstruction and achieve improvements hereafter, by comparing the results of double bundle and single bundle reconstruction using tibialis anterior allograft. Materials and Methods: Twenty seven patients were divided to undergo either double bundle(n=14) or single bundle(n=13) reconstruction with tibialis anterior allograft tendon. The evaluation methods were AP laxity with KT-2000 arthrometer, isokinetic knee strength measurements, pivot-shift test, IKDC subjective score, Lysholm knee score, Tegner activity score, radiographic evaluations with postoperative MRI, and second look arthroscopy. Results: Lysholm knee score and Tegner activity score were significantly better in double bundle reconstruction. In pivot-shift test, single bundle reconstruction was evaluated as grade 0 in 10 of the knees, grade 1 in 1, and grade 2 in 2. Double bundle reconstruction was evaluated as grade 0 in 13, and grade 2 in 1. In second look arthroscopy, single bundle was evaluated as excellent in 6 of the knees, fair in 7, anteromedial bundle of double bundle reconstruction was excellent in 13 and fair in 1, and posterolateral bundle was excellent in 4, fair in 9, and poor in 1. There were no significant differences in other evaluations. Conclusion: Favorable outcome may be expected with double bundle reconstruction of ACL. However there are still need for improvement in terms of reconstruction technique and rehabilitation protocol to reduce PL bundle injury.

  • PDF

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

The evaluate the usefulness of various CT kernel applications by PET/CT attenuation correction (PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가)

  • Lee, Jae-Young;Seong, Yong-Jun;Yoon, Seok-Hwan;Park, Chan-Rok;Lee, Hong-Jae;Noh, Kyung-Wun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.37-43
    • /
    • 2017
  • Purpose Recently PET/CT image's attenuation correction is used CTAC(Computed Tomgraphy Attenuation Correction). it can quantitative evaluation by SUV(Standard Uptake Value). This study's purpose is to evaluate SUV and to find proper CT kernel using CTAC with applied various CT kernel to PET/CT construction. Materials and Methods Biograph mCT 64 was used for the equipment. We were performed on 20 patients who had examed at our hospital from february through March 2017. Using NEMA IEC Body Phantom, The data was reconstructed PET/CT images with CTAC appiled various CT kernel. ANOVA was used to evaluated the significant difference in the result. Results The result of measuring the radioactivity concentration of Phantom was B45F 96% and B80F 6.58% against B08F CT kernel, each respectively. the SUVmax increased to B45F 0.86% and B80F 6.54% against B08F CT kernel, In case of patient's parts data, the Lung SUVmax increased to B45F 1.6% and B80F 6.6%, Liver SUVmax increased to B45F 0.7% and B80F 4.7%, and Bone SUVmax increased to B45F 1.3% and B80F 6.2%, respectively. As for parts of patient's about Standard Deviation(SD), the Lung SD increased to B45F 4.2% and B80F 15.4%, Liver SD increased to B45F 2.1% and B80F 11%, and Bone SD increased to B45F 2.3% and B80F 14.7%, respectively. There was no significant difference discovered in three CT kernel (P >.05). Conclusion When using increased noise CT kernel for PET/CT reconstruction, It tends to change both SUVmax and SD in ROI(region of interest), Due to the increase the CT kernel number, Sharp noise increased in ROI. so SUVmax and SD were highly measured, but there was no statistically significant difference. Therefore Using CT kernel of low variation of SD occur less variation of SUV.

  • PDF

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.