• Title/Summary/Keyword: Patient table

Search Result 206, Processing Time 0.022 seconds

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Usability Research of Onco Flash in SPECT (SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가)

  • Noh, Ik-Sang;Cha, Eun-Sun;Kim, Ki;Choi, Choon-Ki;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.3-8
    • /
    • 2009
  • Purpose: Onco flash shortens a scan time with half and there is a possibility of getting the data which corresponds in existing. The experiment which makes the image whose Onco Flash is excellent OSEM tried, as changes parameter of time, iteration. After reconstituting an image, produces FWHM and executes an evaluation. Materials and Methods: Siemens e.cam gamma camera, standard Jaszczak phantom and spatial resolution phantom was used. In order for the bubble not to enter, implants 2 mCi and volume 0.25 cc $^{99m}Tc$ respectively in line 3 to spatial resolution phantom. Put on that phantom on the table correctly, and acquires an image. 15 mCi putting in distilled water to mix $^{99m}Tc$ well in Jaszczak phantom and acquires image just like spatial resolution phantom. Reconstructs and converts the image to digital image as Sante program. Produce FWHM and evaluate by Amide. Results: The non-scattered image shows better FWHM value than scattered image. As time increases from 10 sec to 30 sec for 5sec interval, FWHM appeared to 30.1, 28.5, 24.5, 23.6, 23.4 mm. At the standard iteration value 4, OSEM FWHM shows 8.0 mm, and Onco Flash is 8.1 mm. As fade in iteration, FWHM value more and more decreased. Conclusion: When using Onco Flash, shortens a scan time, and enhances image quality. Also, user can adjust the parameters to improve resolution. Therefore, patient and user are satisfied with these merits.

  • PDF

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF

Organic Acidopathies as Etiologic Diseases of Developmental Delay in Korean Childhood and Adolescent Age Group (한국인 소아청소년기 발달지연의 원인질환으로서의 유기산대사이상질환)

  • Lee, Jong Yoon;Lee, Ye Seung;Choi, Joong Wan;Bae, Eun Joo;Park, Won Il;Oh, Phil Soo;Lee, Hong Jin
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.12 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: Developmental delay is caused by very diverse etiologic diseases. Most chronic disorders has some influence on development. Chronic or acute disorders of CNS are main etiologic diseases of developmental delay. Up to now, over 60 diseases are included in organic acidopathies and most of them causes acute or chronic recurrent CNS damage and developmental delay. We have done this study to find out the importance of organic acidopathies causing developmental delay in Korean childhood and adolescent patients. Method: Retrograde analysis for 738 patients with developmental delay whose clinical informations are available and have done urine organic acid analysis for 5 years period, between Jan. 1st 2007 to Dec. 31th 2011. Statistical analysis was done with Student's t test using SPSS. Result: Out of 738 patients, 340 patients (46.1%) showed abnormalities on urine organic acid analysis. The most frequent disease was mitochondrial respiratory chain disorders (MRCD) (253, 34.3%), followed by ketolytic defects(39, 5.3%), 3-hydroxyisobutyric aciduria (26, 3.5%), glutaric aciduria type II (8, 1.1%), pyruvate dehydrogenase deficiency (3, 0.4%), 3-methylglutaric aciduria (2, 0.3%), glutaric aciduria type I (2, 0.3%), ethylmalonic aciduria (1, 0.15%), methylmalonic aciduria (1, 0.15%), HMG-CoA lyase deficiency (1, 0.15%), 3-methylcrotonylglycinuria (1, 0.15%), fatty acid oxidation disorders(1, 0.15%) and FAOD (1, 0.15%). Conclusion: Mitochondrial disorders are most frequent etiologic disease on all age group, followed by ketolytic defects and various organic acidopathies. The number and diversities of organic acidopathies emphasize meticulous evaluation of basic routine laboratory examinations and organic acid analysis with initial sample on every developmental patient.

  • PDF

Results of Radiation Therapy in Stage III Uterine Cervical Cancer (병기 III 자궁경부암의 방사선치료 결과)

  • Moon, Chang-Woo;Shin, Byung-Chul;Yum, Ha-Yong;Jeung, Tae-Sig;Yoo, Myung-Jin
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.259-266
    • /
    • 1995
  • Purpose : The aim of this study is to analyze the survival rate, treatment failure and complication of radiation therapy alone in stage III uterine cervical cancer. Materials and Methods : From January 1980 through December 1985, 227 patients with stage III uterine cervical cancer treated with radiation therapy at Kosin Medical Center were retrospectively studied. Among 227 patients, 72 patients($317{\%}$) were stage IIIa, and 155 patients($68.3{\%}$) were stage IIIb according to FIGO classification. Age distribution was 32-71 years (median: 62 years). Sixty nine patients($95.8{\%}$) in stage IIIa and 150 patient ($96.8{\%}$) in stage IIIb were squamous cell carcinoma. pelvic lymph node metastasis at initial diagnosis was 8 patients($11.1{\%}$) in stage IIIa and 29 patients($18.7{\%}$) in stage IIIb, Among 72 patients with stage IIIa, 36 patients ($50{\%}$) were treated with external radiation therapy alone by conventional technique (180-200 cGy/fr.) and 36 patients($50{\%}$) were treated with external radiation therapy with intracavitary radiotherapy(ICR) with $Cs^{137}$ sources, and among 155 patients with stage IIIb, 80 patients ($51.6{\%}$) were treated with external radiation therapy alone and 75 patients ($48.4{\%}$) were treated with external radiation therapy with ICR. Total radiation doses of stage IIIa and IIIb were 65-105 Gy(median: 78.5 Gy) and 65-125.5 Gy (median 83.5 Gy). Survival rate was calculated by life-table method. Results : Complete response rates were $58.3{\%}$(42 patients) in stage IIIa and $56.1{\%}$(87 patients) in stage IIIb. Overall 5 year survival rates were $57{\%}$ in stage IIIa and $40{\%}$ in stage IIIb. Five year survival rates by radiation technique in stage IIIa and IIIb were $64{\%},\;40{\%}$ in the group treated in combination of external radiation and ICR, and $50\%,\;40\%$ in the group of external radiation therapy alone(P=NS). Five year survival rates by response of radiation therapy in stage IIIa and IIIb were $90\%,\;66\%$ in responder group and $10\%,\;7\%$ in non-responder group (P<0.001) There were statistically no significant differences of 5 year survival rate by total radiation doses and external radiation doses(40 Gy vs 50 Gy) of whole or true pelvis in stage IIIa and IIIb(P=NS). Treatment failures rates were $40.3\%$(29 patients) in stage IIla and $57.4\%$(89 patients) in stage IIIb. 17 patients ($23.6\%$) in stage IIIa and 46 patients ($29.7\%$) in stage IIIb experienced complications. Total radiation doses more than 85 Gy produced serious complication in both stage IIIa($50\%$) and IIIb($50\%$). Serious complication rates were higher in group received external radiation doses of 50 Gy than 40 Gy to whole or true pelvis in stage IIIa and IIIb. Serious rectal complication developed in rectal doses more than 65 Gy, and serious bladder complication developed in bladder doses more than 75 Gy. Major cause of death was cachexia due to locoregional failure in both stage IIIa($34.7\%$) and IIIb($43.9\%$). Conclusion : From this study, we found that external radiation therapy with ICR was found to have a tendency to be superior to external radiation therapy alone in survival rate, local control rate and complication rate but not different in statistics, and external radiation doses of 50 Gy than 40 Gy to whole or true pelvis produced serious rectal and bladder complications in stage III uterine cervical cancer.

  • PDF

Arthroscopic Subscapularis Tendon Repair - Preliminary Report of 8 cases study - (관절경하 견갑하건 봉합술 - 8 례에 대한 예비보고 -)

  • Yun, Ho-Hyun;Moon, Gi-Hyuk;Jang, Jong-Hoon;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.124-131
    • /
    • 2004
  • Purpose: To validate and introduce the technique of the arthroscopic repair for the treatment of the Subscapulris tendon tear. Materials and Methods: From April 2003 to April 2004, Arthroscopic repairs were performed in 8 patient with subscapularis tendon tear. The mean follow-up period was 11months. two cases involved only subscaplaris tendon tear. Four cases were associated small sized posterosuperir. rotator cuff tear and two cases were in large size. The type of subscapularis tendon showed upper portion full-thickness tear in 6 cases, partial-thickness tear localized at articular surface in 1 case, complete tear in 1 case. The results were analyzed by using subjective satisfaction, inferior movenent of superior displaced humeral head, Constant-Murley functional scoring Results: Constant-Murley scoring was improved from 55 point preoperatively to 75 point postoperatively following 11 months. Mean score was 71 point except 2 cases of large superoposterior rotator cuff tear, Most humeral heads were distaracted postoperatively. The subjective result for the 8 shoulders were very satisfying in 5 cases, satisfying in 1 case and dissatisfying in 2 cases. Therefore satisfactory results were noted in 6 cases (75%) of this overall treatment group. Conclusion: The arthroscopic repair for the subscapularis tendon tear is thought to be available method, which could reduce severe complications following the weakness of deltoid muscle and postoperative pain. Especially Partial Subscapularis tear not associated with superoposterior rotator cuff tear including PASTA lesion was the sutable indication of the Arthroscopic repair.

  • PDF