• Title/Summary/Keyword: Patient skin dose

Search Result 146, Processing Time 0.027 seconds

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

Seven-Year Follow Up of Microscopic Polyangiitis Presenting with Rapidly Progressive Glomerulonephritis (급속 진행성 사구체신염으로 시작된 현미경적 다발성 동맥염(Microscopic Polyangiitis) 환자의 7년간의 장기 추적관찰 1례)

  • Oh, Jin-Won;Kim, Pyung-Kil;Lee, Jae-Seung;Jeong, Hyeon-Joo
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.99-104
    • /
    • 2008
  • Microscopic polyangiitis(MPA) is a systemic necrotizing vasculitis that involves many organ systems including the skin, joint, kidneys, and lungs. In spite of early diagnosis and intensive care, the five-year actuarial patient and kidney survival rates are 65% and 55%. We experienced a case in 7-year-old girl of microscopic polyangiitis presenting with rapidly progressive glomerulonephritis which was confirmed by renal biopsy and positive serum perinuclear antineutrophil cytoplasmic autoantibodies(p-ANCA). The diagnosis of patients first renal biopsy was MPA, p-ANCA-associated crescentic glomerulonephritis. The patients second renal biopsy was done 5 years 6 months later since first renal biopsy, and pathologic diagnosis was chronic sclerosing glomerulonephritis, advanced, due to MPA. We began methylprednisolone pulse therapy, combined with a low dose of cyclophosphamide and plasmapheresis therapy. ACE inhibitor, angiotensin II receptor blocker, and cyclophosphamide were used until now and the patients current age is 14 years old. On admission, the patients laboratory findings showed BUN 117 mg/dL and Cr 2.3 mg/dL, while on the hospital day BUN and Cr values fell to 20.8 mg/dL and 1.6 mg/dL. But renal function was progressed to chronic failure with latest laboratory data BUN 51.7 mg/dL and Cr 3.2 mg/dL. ACE inhibitor, angiotensin II receptor blocker and small dose of immunosuppressant with close observation is the key to maintain the patient survival.

  • PDF

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Role of radiotherapy in local control of non-AIDS associated Kaposi's sarcoma patients in Korea: a single institution experience

  • Chang, Ji Hyun;Kim, Il Han
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.153-157
    • /
    • 2012
  • Purpose: There has been no definite consensus on standard treatment, either local or systemic, for the Kaposi's sarcoma (KS). Radiotherapy (RT) can be a good local therapeutic choice especially in non-AIDS associated KS (NAKS) for its indolent behavior. Materials and Methods: Medical records of 17 KS patients treated with RT at the Seoul National University Hospital from February 1998 to January 2012 were retrospectively reviewed. One human immunodeficiency virus (HIV)+ patient with 3 lesions was excluded. The total number of the lesion was 23 among the 16 patients. The median follow-up period was 27.9 months. Correlation between response and variables was analyzed using the logistic regression model. Median age of the patients was 75 years. All the 23 lesions were located at the extremities. Fourteen (61%) of those had pain or local swelling as the initial presentation. Ten patients had possible causes of immunodeficiency and were regarded as iatrogenic, and other 6 were classic KS. Median dose of RT was 36 Gy. Results: No KS-related death was observed. Excluding 2 with short-term follow-up only, complete response and partial response were obtained in 2 (9%) and 19 (73%) lesions, respectively. Of those, 3 lesions underwent local progression. Six had out-of-field recurrence after RT. Symptom improvement was achieved in 13 (93%) of 14 patients. Grade 2 skin toxicities were found in 9 lesions but all got improvement after treatment. When divided into responsive and progressive group, free from progression was not related to any of the possible variables. Conclusion: RT is effective in local control of NAKS resulting great response rate.

A Case of Microscopic Polyangiitis with Diffuse Alveolar Hemorrhage (폐출혈을 동반한 현미경적 다발혈관염 1예)

  • Lee, Sang-Jin;Lee, Jae-Woung;Kim, Hye-Jin;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Park, Hye-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.101-107
    • /
    • 2004
  • Diffuse alveolar hemorrhage is a rare but serious and frequently life-threatening complication of a variety of conditions. The first goal in the management of patients with diffuse alveolar hemorrhage is to achieve or preserve stability of the respiratory status. Subsequently, the differential diagnosis is aimed at the identification of a remediable cause of the alveolar hemorrhage. The most common causes of diffuse alveolar hemorrhage with glomerulonephritis are microscopic polyangiitis and Wegener's granulomatosis, followed by Goodpasture syndrome and systemic lupus erythematosus. Microscopic polyangiitis (MPA) is a distinct systemic small vessle vasculitis affecting small sized vessels with few or no immune deposits and with no granulomatosus inflammation. The disease may involve multiple organs such as kidney, lung, skin, joint, muscle, gastrointestinal tract, eye, and nervous system. MPA is strongly associated with antineutrophil cytoplasmic autoantibody (ANCA) that is a useful serological diagnostic marker for the most common form of necrotizing vasculitis. Our report concerns a case of microscopic polyangiitis with diffuse alveolar hemorrhage in a 54-year-old man. He was admitted to our hospital due to dyspnea upon exertion and recurrent hemoptysis. Laboratory findings showed hematuria, proteinuria and deterioration of renal function. In the chest CT scan, diffuse ground glass appearance was seen in both lower lungs. A lung biopsy revealed small vessel vasculitis with intraalveolar hemorrhage and showed a positive reaction to against perinuclear ANCA. The patient was treated with prednisolone and cyclophosphamide. Chest infiltration decreased and hemoptysis and hypoxia improved. He is still being followed up in our hospital with a low dose of prednisolone.

  • PDF

A novel schedule of accelerated partial breast radiation using intensity-modulated radiation therapy in elderly patients: survival and toxicity analysis of a prospective clinical trial

  • Sayan, Mutlay;Wilson, Karen;Nelson, Carl;Gagne, Havaleh;Rubin, Deborah;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.32-38
    • /
    • 2017
  • Purpose: Several accelerated partial breast radiation (APBR) techniques have been investigated in patients with early-stage breast cancer (BC); however, the optimal treatment delivery techniques remain unclear. We evaluated the feasibility and toxicity of APBR delivered using intensity-modulated radiation therapy (IMRT) in elderly patients with stage I BC, using a novel fractionation schedule. Materials and Methods: Forty-two patients aged ${\geq}65$ years, with stage I BC who underwent breast conserving surgery were enrolled in a phase I/II study evaluating APBR using IMRT. Forty eligible patients received 40 Gy in 4 Gy daily fractions. Patients were assessed for treatment related toxicities, and cosmesis, before APBR, during, and after completion of the treatment. Results: The median age was 73 years, median tumor size 0.8 cm and the median follow-up was 54 months. The 5-year locoregional control was 97.5% and overall survival 90%. Erythema and skin pigmentation was the most common acute adverse event, reported by 27 patients (69%). Twenty-six patients (65%) reported mild pain, rated 1-4/10. This improved at last follow-up to only 2 (15%). Overall the patient and physician reported worst late toxicities were lower than the baseline and at last follow-up, patients and physicians rated cosmesis as excellent/good in 93% and 86 %, respectively. Conclusion: In this prospective trial, we observed an excellent rate of tumor control with daily APBR. The acceptable toxicity profile and cosmetic results of this study support the use of IMRT planned APBR with daily schedule in elderly patients with early stage BC.

Antibody Response to Crude Cell Lysate of Propionibacterium acnes and Induction of Pro-Inflammatory Cytokines in Patients with Acne and Normal Healthy Subjects

  • Basal, E.;Jain, A.;Kaushal, G.P.
    • Journal of Microbiology
    • /
    • v.42 no.2
    • /
    • pp.117-125
    • /
    • 2004
  • Propionibacterium acnes (P. acnes) plays an important role in the disease pathogenesis of acne vulgaris, a disorder of pilosebaceous follicles, seen primarily in the adolescent age group. In the present study, the presence of antibodies against P. acnes (MTCC1951) were detected in acne patient (n=50) and disease free controls (n=25) using dot-ELISA and Western blot assay. The ability of P. acnes to induce pro-inflammatory cytokines by human peripheral blood mononuclear cells (PBMCs), obtained from acne patients and healthy subjects, were also analysed. The patients (n=26) who were culture positive for skin swab culture, were found to have a more advanced disease and higher antibody titres (1:4000 to >1:16000) compared to the P. acnes negative patients (n=24) and normal controls (n=25). An analysis of patients' sera by western blot assay recognized a number of antigenic components of P. acnes, rang-ing from 29 to 205 kDa. The major reactive component was an approximately 96 kDa polypeptide, which was recognised in 92% (24 of 26) of the patients sera. Further, the P. acnes culture supernatant, crude cell lysate and heat killed P. acnes whole cells, obtained from 72-h incubation culture, were observed to be able to induce significant amounts of IL-8 and tumor necrosis factor alpha (TNF-${\alpha}$) by the PBMCs in both the healthy subjects and patients, as analysed by cytokine-ELISA. The levels of cytokines were significantly higher in the patients than the healthy subjects. A major 96 kDa polypep-tide reactant was eluted from the gel and was found to cause dose dependent stimulation of the pro-ductions of IL-8 and TNF-${\alpha}$. Thus, the above results suggest that both humoral and pro-inflammatory responses play major roles in the pathogenesis of acne.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF