• Title/Summary/Keyword: Patient reliability index

Search Result 57, Processing Time 0.023 seconds

A Research on Trust Realization Strategies for Oriental Medical Quality Improvement (한방의료 품질 향상을 위한 신뢰구현 체계구축 연구)

  • Kim, Hyun Ji;Kim, So Youn;Ji, Young Seung;Nam, Seung Kyu;Kim, Jeong Ho;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.31 no.1
    • /
    • pp.75-93
    • /
    • 2014
  • Objectives : This study was designed to establish medical trust realization system by finding factors influential to it using questionnaire. Methods : 277 subjects were participated in this study. After a treatment, we conducted a survey from April 1st to October 31th about medical service perception index, medical trust index, patient satisfaction index, patient reliability index, patient flow degree index, recall intension index, and hospital image index. To evaluate the influence of medical service perception with other 6 indexes, we statistically made regression analysis of the results through the survey. Results : By the results of the analysis, evaluation of hospital image influenced all 6 indexes. The systemicity of treatment process had an effect on 5 indexes except for the flow degree of patients. The humanity of medical team brought out the estimation of 4 indexes except for the patient flow degree and hospital image. The empathic ability of doctor and appropriacy of medical costs hold the next rank influencing 3 indexes. It reached the conclusion that the systemicity of medical team tend to determine the medical trust and patient reliability. The expertise, professional skill of doctor, the fault, commercial application, fame of medical team, the speed of treatment process, the newest and clean medical facility affected each one index. Conclusions : Korean medicine should find a way to consider the mind of patients for improving the medical quality through trust realization system, keeping up with times. As a result of this research, we can find out important causes which influence the trustful medical system. From now on, we should apply this result to actual treatment of psychology customized system. Also, more simple and clear questionnaire was organized through this research, it can be used to forward research to apprehend patient mentality more conveniently.

Verification of Reliability and Validity of KPCS-1 and Estimation of Nursing Time Conversion Index (한국형 환자분류도구-1(KPCS-1)의 신뢰도와 타당도 검증 및 간호시간 환산지수 산출)

  • Song, Kyung Ja;Kim, Eun Hye;Yoo, Cheong Suk;Park, Hyeoun Ae;Song, Mal Soon;Park, Kwang Ok
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.2
    • /
    • pp.127-140
    • /
    • 2010
  • Purpose: This study was performed to verify reliability and validity of Korean Patient Classification System for nurses(KPCS-1), to estimate nursing time conversion index, and to classify patients into groups according to KPCS-1 scores. Methods: KPCS-1 was revised from KPCS by a professional review team. Interrater reliability and construct validity of KPCS-1 were verified by data from 433 patients. Direct and indirect nursing time of 204 patients were measured by stopwatch observation and self reports for 24 hours. Nursing time conversion index was calculated. Results: KPCS-1 consisted of 12 area, 50 nursing activities, and 73 items. The interrater reliability was tested between two nurse group (r=.88, p<.001) and construct validity was verified according to medical department (F=10.97, p<.001) and patient pattern (F=5.54, p=.001). The correlation of nursing time and classification score was also statistically significant (r=.56, p<.001). The nursing time conversion index was 9.03 minutes per 1 classification score. The patients were classified into 4 groups by the classification scores. Conclusion: KPCS-1 can be a useful factor type patient classification system for general ward. Further study is needed to evaluate validity and reliability for refining KPCS-1 and to develop ways connecting the scores with nursing outcomes.

Reliability and Validity Tests of Patient Classification System Based on Nursing Intensity (간호강도에 의한 환자분류도구의 신뢰도 및 타당도 검증)

  • Park, Jung-Ho;Kim, Eun-Hye
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.13 no.1
    • /
    • pp.5-16
    • /
    • 2007
  • Purpose: This study is to verify the validity and reliability of classified items and criteria of the patient classification system(PCS) based on Park's definition of nursing intensity. Methods: An expert group of 8 persons verified the content validity of the tools. The 1817 inpatients at a tertiary hospital in Seoul, Korea were classified into 4 groups according to two tools for verifying concurrent validity and interraters' reliability. These verifications were performed from September to October, 2004. Results: Nursing domains of the tools have been divided into 12 items: hygiene, nutrition, elimination, exercise & activity, education & counseling, emotional support, communication & consciousness, treatment & examination, medication, measurement & observation, coordination of multidisciplinary team, admission & discharge & transfer management. Content validity was verified by the content validity index(above 0.75 in all 12 areas). Interraters' reliability was no significant difference in the results of the patient classification between the two raters(A group 93.75%. B group 88.24%). Concurrent validity was also verified by the agreement of two tools(73.7%). Conclusion: These results showed that the reliability and validity of the PCS based on the nursing intensity were verified. These will use an data for nursing productivity in the future.

  • PDF

Reliability and Validity of the Korean Western Ontario and McMaster Universities(WOMAC) Osteoarthritis Index in Patients with Osteoarthritis of the Knee (퇴행성 슬관절염 환자에 대한 한글판 WOMAC Index의 신뢰도와 타당성에 관한 연구)

  • Ko, Tae-Sung;Kim, Seong-Yeol;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.251-260
    • /
    • 2009
  • Objectives : To investigate reliability and validity of Korean translation of Western Ontario and McMaster Universities(WOMAC) osteoarthritis index. Methods : The reliablity, construct validity of the Korean WOMAC Index in the patient of knee osteoarthritis was investigated. Test-retest reliability was quantified with pearson's correlation coefficient and intraclass correlation coefficient. Internal consistency was quantified with Cronbach's ${\alpha}$. and construct validity with pearson's correlation coefficient by correlating of the Visual Analog Scale(VAS). Results : Test-retest reliability of Korean WOMAC Index for pain was 0.76 to 0.95, stiffness was 0.89 to 0.94, and physical function was 0.71 to 0.95. Intraclass correlation coefficient for pain was 0.76 to 0.94, stiffness was 0.54 to 0.89, and physical function was 0.70 to 0.95. Internal consistency were 0.94 and 0.94 for the first and second time, respectively. Construct validity for pain was 0.79, for stiffness was 0.66, and physical function was 0.67. Conclusions : The Korean translation of Western Ontario and McMaster Universities(WOMAC) osteoarthritis index is reliable, valid assessment tool in knee osteoarthritis.

Validity and Reliability Tests of Neonatal Patient Classification System Based on Nursing Needs (간호요구 정도에 의한 신생아중환자 분류도구의 타당도 및 신뢰도 검증)

  • Ko, Bum Ja;Yu, Mi;Kang, Jin Sun;Kim, Dong Yeon;Bog, Jeong Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.3
    • /
    • pp.354-367
    • /
    • 2012
  • Purpose: This study was done to verify validity and reliability of a neonatal patient classification system (NeoPCS-1). Methods: An expert group of 8 nurse managers and 40 nurses from 8 Neonatal Intensive Care Units in Korea, verified content validity of the measurement using item level content validity index (I-CVI). The participants were nurses caring for 469 neonates. Data were collected from November 11 to December 14, 2011 and analyzed using descriptive statistics, ANOVA, intraclass correlation coefficient, and K-cluster analysis with PASW 18.0 program. Results: Nursing domains and activities included 8 items with 91 activities. I-CVI was above .80 in all areas. Interrater reliability was significant between two raters (r=.95, p<.001). Classification scores for participants according to patient types and nurses' intuition were significantly higher for the following patients; gestational age (${\leq}29$ weeks), body weight (<1,000 gm), and transfer from hospital. Six groups were classified using cluster analysis method based on nursing needs. Patient classification scores were significantly different for the groups. Conclusion: These results show adequate validity and reliability for the NeoPCS-1 based on nursing needs. Study is needed to refine the measurement and develop index scores to estimate number of nurses needed for adequate neonatal care.

Study on function evaluation tools for stroke patients (뇌졸중(腦卒中) 환자(患者)의 기능평가방법(機能評價方法)에 대(對)한 연구(硏究))

  • Ko, Seong-Gyu;Ko, Chang-Nam;Chox, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.48-83
    • /
    • 1996
  • Our conclusions for function evaluation tools of Stroke patients are as follows. 1. Evaluating tools of Activities of Daily Living, Katz Index, Barthel Index, Modified Barthel Index have high validity and reliability because of ease of measuring, high accuracy, consistency, sensitivity and sufficient stastistics, but they mainly measure motor function except sense, mentation, language, and social conception. Therefore cerebrovascular disease and brain injury in trauma patients with lacked acknowledgement and sensation, we are not able to apply these tools. 2. PULSES Profile is a useful scale for measuring the patient's over-all status, upper and lower limb functions, sensory components, excretary functions, and intellectual and emotional adaptabilities. It is recognized as a good, useful tool to evaluate patient's whole function. 3. Motor Assessment Scale was designed to measure the progress of stroke patients. The scale was supplemented with upper arm function items. We believe that the Motor Assessment Scale could be a useful evaluation tool with inter-rater reliability ,test-retest reliability. 4. The existing evaluation tools, Katz Index, Barthel Index, Modified Barthel Index, PULSES Profile, Motor Assessment Scale, mainly measured the rehabilitational motor function of sequela of cerebrovascular patients. On the other hand CNS & INH stroke scale can measure cerebrovascular disease patient's neurologic deficits and over-all stautus, which are recognition ability, speech status, motor function, sensory function, activities of daily living. Those scales have been recognized as useful tools to measure function of cerebrovascular disease patients and have increased in use. 5. Every function evaluation tool was recognized to have some validity and inter-rater, test-retest reliability in items of each evaluation tool and total scores of each evaluation tools, but it is thought that none of these scales have been fully validated and proved reliable. Therefore afterward, the development of a highly reliable rating system may best be accomplished by a careful comparison of several tools, using the same patients and the same observers in order to choose the most reliable items from each. 6. Ideal evaluation tools must have the following conditions; (1) It should show the objective functional statues at the same time. (2) It should be repeated consecutively to know changed function status. (3) It should be easy to observe the treatment program. (4) It should have the same result with another rater to help rater exchange information with treatment team members. (5) It should be practical and simple. (6) The patient should not suffer from the observer.

  • PDF

Verification of the Reliability and Validity of the Korean Pediatric Patient Classification System and Estimation of Nursing Time Conversion Index (한국형 소아 환자 분류도구의 신뢰도와 타당도 검증 및 간호시간 환산지수 산출 연구)

  • Sim, Mi Young;Park, Ji Sun;Kwon, Mi Kyung;Song, Suk Hee;Kim, Ye Seul;Kang, Min Seo;Lee, Shin Ae;Choi, Eun Seok;Ha, Eun Ju
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.185-197
    • /
    • 2022
  • Purpose: This study was performed to verify reliability and validity of the Korean Pediatric Patient Classification System (KPPCS) and estimate nursing time conversion index. Methods: The study was conducted in 9 children's hospital which included various areas and size of bed settings. To verify intraclass correlation reliability and construct validity, staff nurses and nurse managers of 21 wards classified 575 patients according to KPPCS comparing differences by age, days of stay, type of stay and medical department. Direct and indirect nursing time of 575 patients were measured by 284 nursing staffs by stopwatch observation and self reports for 24 hours. Results: KPPCS has 12 categories, 55 nursing activities and 80 criterions. High agreement among nurses (r=.91, p<.001) suggested substantial reliability. Construct validity was verified by comparing differences in age, days of stay, type of stay and medical department (p<.05). The correlation of nursing time and classification score was also statistically significant (r=.59, p<.001). The nursing time conversion index was 10.78 minutes per 1 classification score. The entire patient group were classified to four groups using KPPCS. Conclusion: The findings suggest that KPPCS would be a useful tool for estimating nursing demands related to the complexity of pediatric patients.

A Novel Dental Plaque Index Using Intraoral Camera Images

  • Ji-Soo Kim
    • Journal of dental hygiene science
    • /
    • v.24 no.3
    • /
    • pp.200-207
    • /
    • 2024
  • Background: This study aimed to evaluate whether a Novel Plaque Index (NPI) using intraoral camera images would be more useful for assessing the accumulated area of dental plaque compared to three other indices. Methods: This study evaluated 80 disclosed plaque tooth surface images from 40 participants, including the facial surfaces of the maxillary left first molar and mandibular left central incisor. The tooth surface was divided longitudinally into three sections, with each section further subdivided into four subsections. A score ranging from 0 to 5 was assigned to each longitudinal third, and the average score was determined as the NPI score for the tooth surface. Two examiners assessed the NPI, Patient Hygiene Performance Index, Quigley and Hein Plaque Index, and Rustogi's Modified Navy Plaque Index scores obtained using the plaque images. The assessments were repeated twice with a 2-weeks washout period. The Plaque Percent Index (PPI) score calculated via image analysis is considered the gold standard. Results: The NPI showed the highest correlation coefficient with PPI compared to the other indices (examiner 1: 0.87, examiner 2: 0.88). The intraexaminer reliability of the NPI was excellent for both examiners. The intraclass correlation coefficient (ICC) for examiner 1 and 2 was 0.95 and 0.93, respectively. The weighted kappa values were >0.85 for both examiners. The ICC of the interexaminer analysis was 0.93 and the weighted kappa showed a reliability value of 0.81. Conclusion: The NPI was found to have greater validity and reliability than the three existing indices for the quantitative scoring of dental plaque.

Reliability, Validity, and Conversion Index of the Workload Management System for Critical Care Nurses(WMSCN) (중환자 분류도구(WMSCN)의 신뢰도, 타당도 및 환산지수 검증)

  • Yoo, Cheong-Suk;Kwon, Eun-Ok;Kim, Soon-Hee;Cho, Yong-Ae
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.48-57
    • /
    • 2009
  • Purpose: The purpose of this study is to establish reliability and validity and to identify the conversion index. Method: The WMSCN for ICU was revised from Workload Management System for Nurses(WMSN) of Walter Reed Army Hospital. Reliability of the WMSCN was evaluated interrater reliability between head nurses and staff nurses at 124 patients in April 2008. Validity through the correlation between direct nursing care hours and WMSCN score was conducted at 20 ICUs of 10 hospitals. Finally the conversion index was identified by total nursing hours and it divided by WMSCN score. Results: The scores by nurses were highly correlated with head nurses’(p=.967), and also scores of the WMSCN were highly correlated with the direct nursing care hours(p<.001). The distribution of patient classification ranks into class V(61.3%), class IV(24.2%) and class VI(11.3%). The scores of the WMSCN were no differences between MICU and SICU. Finally, the conversion index was 8.2 minutes. Conclusion: WMSCN is available to classify the nursing workload for critical care patients. The repeated evaluation of validity and reliability are requisite to use WMSCN effectively. And the conversion index should be adjusted to estimate the appropriate staffing in Korea.

  • PDF

Validity and Reliability on the Walking Index for Spinal Cord Injury in the walking assessment of the SCI patient (척수손상환자에서 보행 기능 평가도구인 WISCI II의 타당도와 신뢰도)

  • Lee Hyoung-Soo;Jeong Chan-Ju;Yang Hoi-song;Shin Young-Il
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.142-151
    • /
    • 2004
  • The purpose of this study was to determine the validity and the reliability of the WISCI II to ascertain its value in the walking function evaluation of spinal cord injury patient. The WISCI II consists of 20 variables with a total valus ranging from 6 to 20 score. A group of 23 spinal cord injury patient were included in this study. To determine the validity, kappa statistics between the WISCI II and SCIM II were measured. The result of this study are as follows: 1) In the validity study, the kappa statistics between the WISCI II and SCIM II were 0.79 and 0.84 for an initial total score and a discharge total score respectively, indicating a reasonable agreement between the two test. 2) In the reliability study, the Cronbach's alpha coefficient was 0.83 and 0.95 for total score indicating a good internal consistency. The finding suggest that the WISCI II demonstrated an acceptable validity and reliabilit for the evaluation of walking function capacity of spinal cord injury patient in clinical practice.

  • PDF