Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.

Minimized Radiation Dose of Patients Receiving High Dose Radioiodine(I-131) Therapy (고용량 방사성옥소(I-131) 치료환자의 피폭선량 저감화 연구)

  • Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.435-442
    • /
    • 2007
  • The number of thyroid diseases treated with radioiodine(I-131) is increasing steadily. The sharp increase in patients who require high dose radioiodine therapy greatly increased the need for new therapy rooms. Accordingly, interest in radiation exposure is rising as well, and is a major psychological stress factor for the patient and those who come in close contact with the patient. This study aimed to minimize the radiation exposure on discharge. Based on various previous reports, the decision for discharge should be individualized depending on many factors related to the patient's living or working environment. Educating patients repeatedly on the importance of sufficient oral hydration, while the adequate amount was relative to the patient's individual condition, greatly lowered the detected radiation measurement within the same admission period. In some cases, the period of admission could be abbreviated.

  • PDF

Use of Acellular Biologic Matrix Envelope for Cardiac Implantable Electronic Device Placement to Correct Migration into Submuscular Breast Implant Pocket

  • Peyton Terry;Kenneth Bilchick;Chris A. Campbell
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.156-159
    • /
    • 2023
  • Breast implants whether used for cosmetic or reconstructive purposes can be placed in pockets either above or below the pectoralis major muscle, depending on clinical circumstances such as subcutaneous tissue volume, history of radiation, and patient preference. Likewise, cardiac implantable electronic devices (CIEDs) can be placed above or below the pectoralis major muscle. When a patient has both devices, knowledge of the pocket location is important for procedural planning and for durability of device placement and performance. Here, we report a patient who previously failed subcutaneous CIED placement due to incision manipulation with prior threatened device exposure requiring plane change to subpectoral pocket. Her course was complicated by submuscular migration of the CIED into her breast implant periprosthetic pocket. With subcutaneous plane change being inadvisable due to patient noncompliance, soft tissue support of subpectoral CIED placement with an acellular biologic matrix (ABM) was performed. Similar to soft tissue support used for breast implants, submuscular CIED neo-pocket creation with ABM was performed with durable CIED device positioning confirmed at 9 months postprocedure.

Analysis of Patient Exposure dose with Glass Dosimeter (Glass Dosimeter를 이용한 환자피폭선량에 관한 분석)

  • Kim, Jae-In;Choi, Won-Keun;Chang, Sung-Won;Oh, Chang-Seop;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF

Development and use of Supporting Device for Patellar X-ray Imaging (슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Lee, Sang-Hun;Kim, Jong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.

A MODEL FOR PROTECTIVE BEHAVIOR AGAINST THE HARMFUL EFFECTS OF RADIATION FOR RADIOLOGICAL TECHNOLOGISTS IN MEDICAL CENTERS

  • Han, Eun-Ok;Moon, In-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.95-101
    • /
    • 2009
  • Protective behavior of radiological technologists against radiation exposure is important to achieve reduction of the patient doses without compromising medical achievements. This study attempts to provide a basic model for the sophisticated intervention strategy that increases the level of the protective behavior of the technologists. The model was applied to real situations in Korea to demonstrate its utility. The results of this study are summarized as follows: First, the protective environment showed the highest relationship in the factors considered, r=0.637 (p<0.01). Secondly, the important factors were protective environment in environment characteristics, expectation for the protective behavior 0.228 (p<0.001), self-efficacy 0.142 (p<0.001), and attitude for the protective behavior 0.178 (p<0.001) in personal characteristics, and daily patient -0.112 (p<0.001) and number of the participation in the education session for the protective behavior 0.074 (p<0.05). Thirdly, the final protective behavior model by a path analysis method had direct influence on the attitude 0.171 (p<0.01) and environment 0.405 (p<0.01) for the protective behavior, self efficacy 0.122 (p<0.01), expectation for the protective behavior 0.16 (p<0.01), and self-efficacy in the specialty of projects 0.154 (p<0.01). The acceptance of the model determined by the absolute fit index (GFI), 0.969, and by the incremental fit index (CFI), 0.943, showed very significant levels. Value of $x^2$/df that is a factor applied to verify the acceptance of the model was 37, which implies that the result can be accepted in the desirable range. In addition, the parsimonious fit index configured by AGFI (0.890) and TLI (0.852) was also considered as a scale that accepts the model in practical applications. In case of the establishment of some specific intervention strategies based on the protective behavior model against harmful radiation effects proposed in this study, the strategy will provide an effective way to prevent medical harmful radiation effects that could cause severe injuries to people.

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

Medical Exposure of Korean by Diagnostic Radiology and Nuclear Medicine Examinations (진단방사선 및 핵의학 검사에 의한 한국인의 의료상 피폭)

  • Kwon, Jeong-Wan;Jeong, Je-Ho;Jang, Ki-Won;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.185-196
    • /
    • 2005
  • Although medical exposure from diagnostic radiology procedures such as conventional x-rays, CT and PET scans is necessary for healthcare purposes, understanding its characteristics and size of the resulting radiation dose to patients is much of worth because medical radiation constitutes the largest artificial source of exposure and the medical exposure is in a trend of fast increasing particularly in the developed society. Annual collective doses and per-caput effective doses from different radiology procedures in Korea were estimated by combining the effective dose estimates per single medical procedure and the health insurance statistics in 2002. Values of the effective dose per single procedure were compiled from different sources including NRPB reports, ICRP 80, MIRDOSE3.1 code and independent computations of the authors. The annual collective dose reaches 27440 man-Sv (diagnostic radiology: 22880 man-Sv, nuclear medicine: 4560 man-Sv) which is reduced to the annual per-caput effective dose of 0.58 mSv by dividing by the national population of 47.7 millions. The collective dose is far larger than that of occupational exposures, in the country operated 16 nuclear power plants in 2002, which is no more than 70 man-Sv in the same year. It is particularly noted that the collective dose due to CT scans amounts 9960 man-Sv. These results implies that the national policy for radiation protection should pay much more attention to optimization of patient doses in medicine.

Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method (전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가)

  • Kim, Young-Pyo;Kim, Tae-Gon;Lee, Ho-Shik;Park, Yong-Pil;Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.