• Title/Summary/Keyword: Patient radiation dose

Search Result 1,016, Processing Time 0.029 seconds

Accelerating Medical Image Processing on Integrated GPU Using OpenCL (OpenCL을 이용한 내장형 GPU에서의 의학영상처리 가속화)

  • Kim, Beom-Jun;Shin, Byeong-seok
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.2
    • /
    • pp.1-10
    • /
    • 2017
  • A variety of filters are applied to improve the quality of noise and low resolution medical images. This is necessary to reduce the radiation dose of the patient and to improve the utilization of the conventional spherical imaging equipment. In the conventional method, it is common to perform filtering using the CPU of the PC. However, it is difficult to produce results in real time by applying various calculations and filters to high-resolution human images using only the CPU performance of a PC used in a hospital. In this paper, we analyze the structure and performance of Intel integrated GPU in CPU and propose a method to perform image filtering using OpenCL parallel processing function. By applying complex filters with high computational complexity to medical images, high quality images can be generated in real time.

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Optimization of Inpatient Management of Radioiodine Treatment in Korea (우리나라에서 방사성옥소입원치료 관리 최적화)

  • Park, Min-Jae;Kim, Jung-Hyun;Jang, Jung-Chan;Kim, Chang-Ho;Jeong, Jae-Min;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.261-266
    • /
    • 2008
  • We established a model to calculate radioactive waste from sewage disposal tank of hospitals to optimize the number of patients receiving inpatient radioiodine therapy within the safety guideline in our country. According to this model and calculation of radioactivity concentration using the number of patients per week, the treatment dose of radioiodine, the capacity and the number of sewage tanks and the daily amount of water waste per patient, estimated concentration of radioactivity in sewage waste upon disposal from disposal tanks after longterm retention were within the safety guideline (30 Bq/L) in all the hospitals examined. In addition to the fact that we could increase the number of patients in two thirds of hospitals, we found that the daily amount of waste water was the most important variable to allow the increase of the number of patients within the safety margin of disposed radioactivity. We propose that saving the water amount be led to increase the number of patients and they allow two patients in an already furnished hospital inpatient room to meet the increasing need of inpatient radioiodine treatment for thyroid cancer.

Development of Sensitivity-Enhanced Detector using Pixelization of Block Scintillator with 3D Laser Engraving (3차원 레이저 각인으로 블록형 섬광체의 픽셀형화를 통한 민감도 향상 검출기 개발)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.313-318
    • /
    • 2019
  • To improve the sensitivity, a detector using a block scintillator was developed. In the pixelated scintillator, a reflector is located between pixels to move the light generated from the scintillator to the photosensor as much as possible, and sensitivity loss occurs in the reflector portion. In order to improve the sensitivity and to have the characteristics of the pixelated scintillator, the block scintillator was processed into a scintillator in pixel form through three-dimensional laser engraving. The energy spectra and energy resolution of each pixel were measured, and sensitivity analysis of block and pixel scintillator was performed through GATE simulation. The measured global energy resolution was 20.7%, and the sensitivity was 18.5% higher than that of the pixel scintillator. When this detector is applied to imaging devices such as gamma camera and positron emission tomography, it will be possible to shorten the imaging time and reduce the dose of patient by using less radiation source.

Retrospective study of osteoradionecrosis in the jaws of patients with head and neck cancer

  • Manzano, Brena Rodrigues;Santaella, Natalia Garcia;Oliveira, Marco Aurelio;Rubira, Cassia Maria Fischer;Santos, Paulo Sergio da Silva
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • Objectives: Osteoradionecrosis (ORN) is one of the most severe complications resulting from radiotherapy (RT) in patients with head and neck cancer (HNC). It is characterized by persistent exposed and devitalized bone without proper healing for greater than 6 months after a high dose of radiation in the area. To describe the profile and dental management of ORN in HNC patients undergoing RT in an oncological clinical research center. Materials and Methods: A retrospective descriptive study was performed to analyze dental records from HNC patients with ORN treated at an oncological clinical research center from 2013 to 2017. A total of 158 dental records for HNC patients were selected from a total of 583 records. Afterwards, this number was distributed to three examiners for manual assessments. Each examiner was responsible for selecting dental records that contained an ORN description, resulting in 20 dental records. Results: Mean patient age was 60.3 years with males being the most affected sex (80.0%). The most affected area was the posterior region of the mandible (60.0%) followed by the anterior region of the mandible (20.0%) and the posterior region of the maxilla (10.0%). The factors most associated with ORN were dental conditions (70.0%) followed by isolated systemic factors (10.0%) and tumor resection (5.0%). There was total exposed bone closure in 50.0% of cases. The predominant treatment was curettage associated with chlorhexidine 0.12% irrigation (36.0%). Conclusion: Poor dental conditions were related to ORN occurrence. ORN management through less invasive therapies was effective for the closure of exposed bone areas and avoidance of infection.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Preliminary Study on Natural Killer Cell Activity for Interfer-on-Gamma Production after Gamma Knife Radiosurgery for Brain Tumors

  • Park, Kawngwoo;Jeong, Sang Soon;Kim, Jung Hoon;Chung, Hyun-Tai;Lee, Eun Jung;Moon, Hyo Eun;Park, Kwang Hyon;Kim, Jin Wook;Park, Hye Ran;Lee, Jae Meen;Lee, Hye Ja;Kim, Hye Rim;Cho, Yong Hwan;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.861-867
    • /
    • 2022
  • Objective : High-dose radiation is well known to induce and modulate the immune system. This study was performed to evaluate the correlation between clinical outcomes and changes in natural killer cell activity (NKA) after Gamma Knife Radiosurgery (GKS) in patients with brain cancer. Methods : We performed an open-label, prospective, cross-sectional study of 38 patients who were treated with GKS for brain tumors, including metastatic and benign brain tumors. All of the patients underwent GKS, and blood samples were collected before and after GKS. NKA was measured using an enzyme-linked immunosorbent assay kit, to measure interferon-gamma (IFNγ) secreted by ex vivo-stimulated NK cells from whole blood. We explored the correlations between NK cell-produced IFNγ (NKA-IFNγ) levels and clinical parameters of patients who were treated with GKS for brain tumors. Results : NKA-IFNγ levels were decreased in metastatic brain tumor patients compared to those with benign brain tumors (p<0.0001). All the patients who used steroid treatment to reduce brain swelling after GKS had an NKA-IFNγ level of zero except one patient. High NKA-IFNγ levels were not associated with a rapid decrease in brain metastasis and did not increase after GKS. Conclusion : The activity of NK cells in metastatic brain tumors decreased more than that in benign brain tumors after GKS.

Dermatofibrosarcoma Protuberans on the Occipital Scalp Showed Uncommon Presentation: A Case Report (비전형적 임상양상을 보이는 후두부의 융기성 피부 섬유 육종에 대한 증례보고)

  • Jiwon Jeong;Chul Hoon Chung;SeongJin Cho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.40 no.1
    • /
    • pp.49-53
    • /
    • 2024
  • Dermatofibrosarcoma protuberans (DFSP) is a rare soft tissue sarcoma, with an incidence of about 0.8% to 5% per million people per year, accounting for 1% of soft tissue sarcomas. In its early stage, DFSP is typically found as a violet or pinkish macule or patch, and it can develop into a palpable mass with ulceration or bleeding. The standard treatment for DFSP is wide local excision of the tumor with a 2- to 3-cm negative margin, and radiation therapy or chemotherapy can be conducted with surgical treatment. A 35-year-old man had a palpable mass on the left side of his occipital scalp without color change, ulceration, or bleeding, which typically are present in malignancy. A magnetic resonance imaging (MRI) scan showed a 3-cm homogenous enhanced mass without adhesion between the scalp and the mass. Unexpectedly, a biopsy revealed the round mass to be DFSP. A wide excision and rotation of the scalp flap were performed. The patient recovered without any complications and received adjuvant radiotherapy at a dose of 60 Gray (Gy) for six weeks. There was no recurrence through six months of follow-up. Here we report this unique case of DFSP with atypical presentation.

Results of Preoperative Concurrent Chemoradiotherapy for Locally Advanced Rectal Cancer (국소진행성 직장암의 수술 전 동시화학방사선요법의 결과)

  • Choi, Sang-Gyu;Kim, Su-Ssan;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.34-42
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: We performed a retrospective non-randomized clinical study of locally advanced rectal cancer, to evaluate the anal sphincter preservation rates, down staging rates and survival rates of preoperative chemoradiotherapy. $\underline{Materials\;and\;Methods}$: From January 2002 to December 2005, patients with pathologically confirmed rectal cancer with clinical stage T2 or higher, or patients with lymph node metastasis were enrolled in this study. A preoperative staging work-up was conducted in 36 patients. All patients were treated with preoperative chemoradiotherapy, and curative resection was performed for 26 patients at Hallym University Sacred Heart Hospital. Radiotherapy treatment planning was conducted with the use of planning CT for all patients. A total dose of $45.0{\sim}52.2\;Gy$ conventionally fractionated three-dimensional radiotherapy was delivered to the whole pelvis. Chemotherapy was given at the first and fifth week of radiation therapy with continuous infusion i.v. 5-FU (Fluorouracil) and LV (Leucovorine). Surgical resection was performed 2 to 4 weeks after the completion of the chemoradiotherapy regimen. $\underline{Results}$: The complete resection rate with negative resection margin was 100% (26/26). However, a pathologically complete response was not seen after curative resection. Surgery was done by LAR (low anterior resection) in 23 patients and APR (abdomino-perineal resection) in 3 patients. The sphincter preservation rate was 88.5% (23/26), down staging of the tumor occurred in 12 patients (46.2%) and down-sizing of the tumor occurred in 19 patients (73%). Local recurrence after surgical resection developed in 1 patient, and distant metastasis developed in 3 patients. The local recurrence free survival rate, distant metastasis free survival rate, and progression free survival rate were 96.7%, 87% and 83.1%, respectively. Treatment related toxicity was minimal except for one grade 3, one grade 4 anemia, one grade 3 leukopenia, and one grade 3 ileus. $\underline{Conclusion}$: Preoperative concurrent chmoradiotherapy for locally advanced rectal cancer seems to have some potential benefits: high sphincter preservation and down staging. Treatment related toxicity was minimal and a high compliance with treatment was seen in this study. Further long-term follow-up with a larger group of patients is required.