• 제목/요약/키워드: Patient mortality

검색결과 1,335건 처리시간 0.025초

인공 조직 판막의 임상 성적 (Clinical Analysis of Bioprosthetic Heart Valves)

  • 김택진
    • Journal of Chest Surgery
    • /
    • 제24권11호
    • /
    • pp.1074-1080
    • /
    • 1991
  • A total and consecutive 62 patients between 13 and 58 years of age receiving biological prosthetic heart valves at the Korea University Hospital from January 1978 through October 1983 were analyzed. Out of 71 valves replaced, 64 were Carpentier-Edwards valves, 4 were Ionescu-Shiley valves, 2 were Angell-Shiley valves, 1 was Hancock valve. Early mortality within 30 days after operation was noted in 4 cases[6.4%]. There were no cases of valve-related early death. The 58 early survivors were followed-up for a total 387 patient-year over a period of 3 years to 12 years[Mean$\pm$S.D: 6.37$\pm$2.51 years] at the follow-up end of April 1991. During follow-up, seven patients died and late mortality rate was 12%. There were two major late complications: the one is thromboembolism[1.6% /patient-year], the other is primary tissue failure[2.76% /patient-year]. Ten patients underwent re-replacement of 13 tissue valves because of primary tissue failure[nine Carpentier-Edwards, two Ionescu-Shiley, two Angell-Shiley]. There was operative mortality. The probabilities of freedom from primary tissue failure were 95.4% and 75.3% at 5 and 10 years after operation respectively, The actuarial survival rates were 86.2% and 81.8% at 5 and 10 years after initial surgery respectively.

  • PDF

다중판막치환술에 대한 임상적 연구 (Clinical Experience of Multiple Valve Replacement)

  • 조창훈
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1346-1353
    • /
    • 1992
  • From Febrary 1984 to July 1992, 138 cases of multiple valve replacements were performed at the Department of Thoracic and Cardiovascular Surgery, Dongsan Medical Center, Keimyung University. There were 81 females and 57 males, and their ages ranged from 19 to 60 years [mean age, 40.1$\pm$10.9 years]. Thirteen of these patients had undergone previous cardiovascular procedures, with an average of 76.3 months between procedures[range, 3 to 180 months]. Mitral and aortic valve replacement were done in 135 patients, 2 underwent triple valve replacement and 1 underwent mitral and tricuspid valve replacement. Associated procedures were necessary in 20 patients[14.5%]. The operative mortality was 5.8% and the most common cause was low cardiac output. Late follow-up of 83% has been accomplished in 130 early survivors, with a late mortality of 5.9%. The late mortality was due to valve thrombosis in 2 patients, cerebral infarction in 1, heart failure in 1, arrhythmia in 1, and bleeding in l. Of those patients who survived, New York Heart Association functional class improved significantly[from 70% class III and IV before to 88% class I and II after]. Actuarial survival rate including all deaths was 88.8% at 8 years. The follow-up studies revealed that thromboembolism, reoperation and bleeding rate were 1.2%/patient-year, 0.85% /patient-year and 0.57%/patient-year at 8 years postoperatively. We concluded that valve thrombosis, embolism, and anticoagulant-related hemorrhage were the main risk factors of longterm survival of patients.

  • PDF

심혈관 수술 신생아의 혈당수준에 따른 환아 결과 (Patient Outcomes according to Blood Glucose Level in Neonates with Cardiovascular Surgery)

  • 황정혜;박형숙
    • Child Health Nursing Research
    • /
    • 제18권1호
    • /
    • pp.43-52
    • /
    • 2012
  • Purpose: The purpose of this study was to provide basic data for suitable neonate blood glucose maintenance by investigating and analyzing the blood glucose level of post cardiovascular surgery neonates in the ICU for the effect of blood glucose levels on the following outcomes; ICU stay, hospital stay, mechanical ventilation time, morbidity, and mortality. Methods: The participants were 143 neonates in the ICU after having had cardiovascular surgery. The design for this study was an investigation of the blood glucose levels of the neonates and retrospective analysis of patient outcomes according to blood glucose level. Results: The results for the neonate groups showed that the factors of hospital stay, ICU stay, mechanical ventilation time and mortality, for the group with a blood glucose level over 140 mg/dL were longer and higher than for the group with blood glucose of less than 100 mg/dL or the group between 100-139 mg/dL. Conclusion: The results of this study indicate that when caring for neonates after cardiovascular surgery, it is important to recognize the influence of blood glucose levels on patient outcomes like hospital days, ICU stay, length of time on mechanical ventilation and mortality. Further, care guidelines for neonates' glucose level management need to be developed.

St. Jude 승모판막의 장기 임상성적 (Long-Term Clinical Results of the St. Jude Medical Valve in Mitral Position)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제27권8호
    • /
    • pp.664-668
    • /
    • 1994
  • A total of 217 patients underwent single mitral valve replacement [MVR] with the St. Jude Medical valve between September 1984 and the end of 1992. There were 86 males and 131 females with a mean age of 34.6 $\pm$ 14.4 years[range 5 months-61 years]. A previous valve replacement had been performed in 46 patients [21.2 %]. An early mortality rate was 7.4 % [5.2 % in primary MVR; and 15.2 %in re-replacement MVR]. Early survivors of 201 patients were followed up for a total of 934.5 patient-years[mean 4.7 $\pm$ 2.1years]. A late mortality rate was 2.5 % or 0.54%/patient-year. The linearized rates of thromboembolism, valve thrombosis and anticoagulation-related bleeding were 1.301 %, 0.214 % and 0.428 %/patient-year, respectively. The actuarial survival including operative mortality was 89.9 % $\pm$ 2.1% at postoperative 10 years. The freedom from thromboemolism was 91.3 %$\pm$ 2.5% and the actuarial estimate of incidence free from late deaths and all complications were 80.9 % $\pm$ 3.8 % at 10 years. There were no mechanical failures. In summary, the St. Jude Medical prosthesis performed satisfactorily with an acceptable rate of late complications.

  • PDF

Mid-Term Results of Thoracic Endovascular Aortic Repair for Complicated Acute Type B Aortic Dissection at a Single Center

  • Hong, Young Kwang;Chang, Won Ho;Goo, Dong Erk;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • 제54권3호
    • /
    • pp.172-178
    • /
    • 2021
  • Background: Complicated acute type B aortic dissection is a life-threatening condition with high morbidity and mortality. The aim of this study was to report a single-center experience with endovascular stent-graft repair of acute type B dissection of the thoracic aorta and to evaluate the mid-term outcomes. Methods: We reviewed 18 patients treated for complicated acute type B aortic dissection by thoracic endovascular aortic repair (TEVAR) from September 2011 to July 2017. The indications for surgery included rupture, impending rupture, limb ischemia, visceral malperfusion, and paraplegia. The median follow-up was 34.50 months (range, 12-80 months). Results: The median interval from aortic dissection to TEVAR was 5.50 days (range, 0-32 days). There was no in-hospital mortality. All cases of malperfusion improved except for 1 patient. The morbidities included endoleak in 2 patients (11.1%), stroke in 3 patients (16.7%), pneumonia in 2 patients (11.1%), transient ischemia of the left arm in 1 patient (5.6%), and temporary visceral ischemia in 1 patient (5.6%). Postoperative computed tomography angiography at 1 year showed complete thrombosis of the false lumen in 15 patients (83.3%). Conclusion: TEVAR of complicated type B aortic dissection with a stent-graft was effective, with a low morbidity and mortality rate.

이오네스큐 판막의 장기 임상성 (Long-term clinical results of isolated mitral valve replacement with the Ionescu-Shiley bovine pericardial valve)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.212-222
    • /
    • 1984
  • A total of and consecutive 291 patients underwent isolated mitral valve replacement using the Ionescu-Shiley bovine pericardial xenograft valve during the 5-year period between October 1978 and June 1983. Thirty-two patients were the children under 15 years of age. There were 15 deaths within 30 days after surgery [operative mortality, 5.2%]. All early survivors except 6 children were placed on the long-term oral anticoagulation longer than postoperative 3 months. A total follow-up period extended for 398.2 patient-years, and 12 patients died [late mortality, 4.1%, or 3.0%/patient- year]. Ten patients experienced the thromboembolic complication [2.51%/patient-year], occurring in 8 patients within the first 3 postoperative months, and 4 died. Three patients had the late prosthetic valve endocarditis [0.75%/patient-year] and 2 died. The incidence of overall valve failure according to the criteria was 3.01%/patient-year, or 12 patients, and 2 had replacement of the failed bioprostheses [primary tissue failure, 0.5%/patient-year]. The long-term survival rate was 87.8%\ulcorner2.6% at 5 years postoperatively, and 84% of the late survivors were in NYHA Class I at the end of the follow- up. The probability remaining free from thromboembolism and overall valve failure was 89.8%\ulcorner6.3% and 81.2%\ulcorner.8% at 5 years respectively. These clinical results confirm the safety of mitral valve replacement. The only remaining clinical problem is the structural and functional durability of the bovine pericardial xenograft valve, and its use in young patients may be stopped in preference to the mechanical prosthetic valves.

  • PDF

쎈트쥬드 중복판막치환의 장기 임상성적 (Clinical Results of Double Mitral and Aortic Valve Replacement with the St. Jude Medical Prosthesis)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.666-670
    • /
    • 1995
  • A total of and consecutive 87 patients underwent concomitant double mitral and aortic valve replacement with the St. Jude Medical prosthesis between January 1985 and December 1993. They were 44 males and 43 females with the ages ranging from 18 to 59 years[mean$\pm$SD: 40.9$\pm$9.5 years . Fifteen patients[17.2% had a history of previous cardiac valve replacement. There were 2 early deaths[2.3% , and 85 early survivors were followed up for a total of 352.6 patient-years[mean$\pm$SD: 4.1 $\pm$2.6 years . All were anticoagulated with coumadin keeping the target international normalized ratio within the range of 1.5 and 2.5. There was a single late death[late mortality of 0.284%/patient-year . Thromboembolism was the most frequent complication[1.985%/patient-year , and bleeding related to anticoagulation was experienced in one patient [0.284%/patient-year . The incidences of prosthetic valve endocarditis and of paravalvular leak were also low[0.284%/patient-year, respectively . The survival including operative mortality was 96.1%$\pm$2.2% at 10 years. The actuarial probabilities of freedom from thromboembolism and from all events were 77.9%$\pm$11.1% and 72.4%$\pm$10.7%, respectively, at 10 years. There was no structural failure of the prosthesis. Results from a series of clinical studies suggest strongly that the use of lower intensity of anticoagulation therapy lowers the thromboembolic as well as bleeding rates in patients with the ST. Jude Medical prosthesis.

  • PDF

동연동성 좌측결장을 이용한 식도재건술 (Esophageal Reconstruction with Isoperistaltic Interposition of Left Colon)

  • 성시찬
    • Journal of Chest Surgery
    • /
    • 제24권9호
    • /
    • pp.895-902
    • /
    • 1991
  • The surgical experience on 18 patients with benign or malignant stricture of the esophagus who underwent isoperistaltic interposition of left colon from April 1989 to July 1991 was reviewed. During same period 22 esophageal reconstructions with colon were performed, but 3 patients who had intraabdominal adhesion in the left upper quadrant and one patient who had uncertainty of blood supply of left colic artery could not undergo iso-peristaltic interposition of left colon. There were 12 male and 6 female patients ranging from 16 to 65 years of age. 12 patients had corrosive esophageal stricture, two had cancer of esophagus, and another two had hypopharyngeal cancer. The postoperative complications developed in 7 patients [38.8%] and most frequently encountered complication was cervical anastomotic leakage, which was successfully managed with simple drainage in all cases but one malignant patient. There was no operative mortality. The esophageal reconstruction with isoperistaltic left colon resulted in good function in 14 patients[77.8%], fair in 3 patients[16.7], and poor in 1 patient[5.6%]. In this experience esophageal reconstruction using isoperistaltic left colon is a satisfactory method that can be accomplished with acceptable morbidity and mortality.

  • PDF

St. Jude Medical 기계판막의 임상적 연구 (Clinical Analysis of St. Jude Medical Prosthesis)

  • 최순호
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

의료기관 간호사 확보수준이 수술환자의 사망, 폐렴, 패혈증, 요로감염에 미치는 영향 (Effects of Hospital Nurse Staffing on in-hospital Mortality, Pneumonia, Sepsis, and Urinary Tract Infection in Surgical Patients)

  • 김윤미;조성현;전경자;신순애;김지윤
    • 대한간호학회지
    • /
    • 제42권5호
    • /
    • pp.719-729
    • /
    • 2012
  • Purpose: This study was done to examine relationships between nurse staffing level and postsurgical patient outcomes using inpatient database from the National Health Insurance. Methods: Records of 111,491 patients who received one of 12 types of surgery between January and December, 2009 were identified and analyzed in this study. Nurse staffing level was measured using adjusted nurse staffing grades from 0 to 7. Patient outcomes were defined as in-hospital mortality, or pneumonia, sepsis, or urinary tract infection after surgery. Logistic regression analyses estimated by Generalized Estimation Model, were used to analyze the association between nurse staffing level and patient outcomes. Results: An inverse relationship was found between nurse staffing and patient mortality. Compared with patients who were cared for in hospitals with the highest nurse staffing (Grades 0-1), increases in the odds of dying were found in those with Grades 6-7 [OR (odds ratio)=2.99, 95% CI (confidence interval)=1.94-4.60], those with Grades 4-5 (OR=1.78, 95% CI=1.24-2.57) and those with Grades 2-3 (OR=1.57, 95% CI=1.25-1.98). Lower nurse staffing level was also associated with higher number of cases in pneumonia and sepsis. Conclusion: Policies for providing adequate nurse staffing is required to enhance quality of care and lead to better perioperative patient outcomes.