• Title/Summary/Keyword: Patient Setup

Search Result 122, Processing Time 0.03 seconds

A Study of Thermoplastic Masks Deformation for Reducing Scattered Ray in Radiation Therapy (방사선치료용 열가소성 플라스틱 마스크의 산란선 감소를 위한 마스크 변형에 관한 연구)

  • Seong-Min, Lee;Jun-Young, Lee;Jae-Hyun, Kim;Kyeong-Hwan, Jeong;Jeong-Min, Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • In head and neck radiation therapy, the thermoplastic immobilization mask used for fixing the patient's posture and reproducibility causes scattered rays by being in close contact with the skin. To investigate the increase in skin dose due to the scattered rays generated from the immobilization mask, we evaluated dose reduction by decreasing contact between face skin and immobilization mask in computerized radiotherapy planning system with CT scanned images. In addition, to confirm the reproducibility problem of the setup due to the decrease in the cover area of immobilizing, the difference of each setup was confirmed using DRR and CT images. As the mask area covered for immobilizing was reduced, the dose on the skin surface significantly decreased, and it was confirmed that there was no significant difference in reproducibility even if the entire face was not covered and fixed.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Prescription, Transcription and Administration Errors in Out-Patient Day Care Unit of a Regional Cancer Centre in South India

  • Mathaiyan, Jayanthi;Jain, Tanvi;Dubashi, Biswajit;Batmanabane, Gitanjali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2611-2617
    • /
    • 2016
  • Background: Medication errors are common but most often preventable events in any health care setup. Studies on medication errors involving chemotherapeutic drugs are limited. Objective: We studied three aspects of medication errors - prescription, transcription and administration errors in 500 cancer patients who received ambulatory cancer chemotherapy at a resource limited setting government hospital attached cancer centre in South India. The frequency of medication errors, their types and the possible reasons for their occurrence were analysed. Design and Methods: Cross-sectional study using direct observation and chart review in anmbulatory day care unit of a Regional Cancer Centre in South India. Prescription charts of 500 patients during a three month time period were studied and errors analysed. Transcription errors were estimated from the nurses records for these 500 patients who were prescribed anticancer medications or premedication to be administered in the day care centre, direct observations were made during drug administration and administration errors analysed. Medical oncologists prescribing anticancer medications and nurses administering medications also participated. Results: A total of 500 patient observations were made and 41.6% medication errors were detected. Among the total observed errors, 114 (54.8%) were prescription errors, 51(24.5%) were transcribing errors and 43 (20.7%) were administration errors. The majority of the prescription errors were due to missing information (45.5%) and administration errors were mainly due to errors in drug reconstitution (55.8%). There were no life threatening events during the observation period since most of the errors were either intercepted before reaching the patient or were trivial. Conclusions: A high rate of potentially harmful medication errors were intercepted at the ambulatory day care unit of our regional cancer centre. Suggestions have been made to reduce errors in the future by adoption of computerised prescriptions and periodic sensitisation of the responsible health personnel.

Complete denture of a skeletal class III patient with occlusal scheme in consideration: A case report (심한 골격성 class III 환자에서 교합양식을 고려한 총의치 수복증례)

  • Lim, Soeun;Kwon, Kung-Rock;Noh, Kwantae;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.50-55
    • /
    • 2018
  • Occlusal disharmony is frequently observed among edentulous patients. When artificial teeth come into contact, the unfavorable displacing force may lead to the discomfort, mucosal trauma, or even neuromuscular alterations and emotional disturbances. An optimal occlusal scheme is a critical factor for successful complete dentures. For this case, an edentulous patient with significant interarch size discrepancy due to mandibular prognathism contributing to inadequate function of dentures was treated with complete dentures. The posterior cross-bite tooth setup for compensating the abnormal jaw relations provided a stable and retentive complete denture prosthesis, which was considered adequate by both patient and dentist.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

Implementation of KV Cone Beam CT for Image Guided Radiation Therapy (영상유도 방사선치료에서의 KV 콘빔CT 이용)

  • Yoo, Young-Seung;Lee, Hwa-Jung;Kim, Dae-Young;Yu, Ri
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • Purpose: The aim of this study was the clinical implementation of IGRT using KV CBCT for setup correction in radiation therapy. Materials and Methods: We selected 9 patients (3 patient for each region; head, body, pelvis)and acquired 135 CBCT images with CLINAC iX (Varian medical system, USA). During the scan, the required time was measured. We analyzed the result in 3 direction; vertical, longitudinal, lateral. Results: The mean setup errors at the couch position of vertical, lateral, and longitudinal direction were 0.07, 0.12, and 0.1 cm in the head region, 0.3, 0.26, and 0.22 cm in the body region, 0.21, 0.18, and 0.15 cm in the pelvis region respectively. The mean time required for CBCT was $6{\sim}7$ minute. Conclusion: The CBCT on the LINAC provides the capacity for soft tissue imaging in the treatment position and real time monitoring during treatment delivery. With presented workflow, the setup correction within reasonable time for more accurate radiation therapy is possible. And it's image can be very useful for adaptive radiation therapy(ART) in the future with improved image quality.

  • PDF

Evaluation of the efficiency of the Vac-lock type belly board in Pelvic cancer Radiation Treatment (골반부 방사선치료 시 자체 제작한 Vac-lock type belly board에 대한 유용성 평가)

  • Kim, YoungYeun;Bang, Seungjae;Jung, Ilsun;Kim, Jungsu;Kim, YoungKon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • Purpose : At the time of the pelvis cancer radiation treatment using the belly board, set-up error is large because of a prone position. In order to improve the reproducibility, we made Vac-lock type belly board. In this study, we attempt to validate its utility. Materials and Methods : We compared belly board and Vac-lock type belly board through the OBI. OBI was performed three times with entire course of treatment and the setup errors in the direction of X axis, Y axis, Z axis were recorded and calculated the distance from the isocenter. Results : X axis, Y axis, Z axis setup errors with existing belly board were 0.32 cm, 0.41 cm, 0.29 cm. The setup errors with the vac-lock type belly board were 0.12 cm, 0.19 cm, 0.17 cm. Further, errors of 0~0.29 cm were increased from 48% to 83% when using VLT belly board. Error of 0.5 cm or more was reduced from 21% to 2%. Conclusion : Vac-lock type belly board is able to maintain the efficacy of existing and create to match the characteristics of the patient. Therefore We think that vac-lock type belly board is very useful in pelvic cancer patients.

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF

The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy (방사선치료 시 자세확인시스템이 처방선량에 미치는 영향)

  • Kim, Jeong-Ho;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.613-620
    • /
    • 2017
  • Planning dose must be delivered accurately for radiation therapy. Also, It must be needed accurately setup. However, patient positioning images were need for accuracy setup. Then patient positioning images is followed by additional exposure to radiation. For 45 points in the phantom, we measured the doses for 6 MV and 10 MV photon beams, OBI(On Board Imager) and CBCT(Conebeam Computed Tomography) using OSLD(Optically Stimulated Luminescent Dosimeter). We compared the differences in the cases where posture confirmation imaging at each point was added to the treatment dose. Also, we tried to propose a photography cycle that satisfies the 5% recommended by AAPM(The American Association of Physicists in Medicine). As a result, a maximum of 98.6 cGy was obtained at a minimum of 45.27 cGy at the 6 MV, a maximum of 99.66 cGy at a minimum of 53.34 cGy at the 10 MV, a maximum of 2.64 cGy at the minimum of 0.19 cGy for the OBI and a maximum of 17.18 cGy at the minimum of 0.54 cGy for the CBCT.The ratio of the radiation dose to the treatment dose is 3.49% in the case of 2D imaging and the maximum is 22.65% in the case of 3D imaging. Therefore, tolerance of 2D image is 1 exposure per day, and 3D image is 1 exposure per week. And it is need to calculation of separate in the parallelism at additional study.

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.