Peritoneal Protein Loss in Nephrotic Syndrome on Peritoneal Dialysis (복막 투석 중인 신증후군 환자의 복막을 통한 단백 소실)
-
- Childhood Kidney Diseases
- /
- v.13 no.2
- /
- pp.189-196
- /
- 2009
Purpose : The pathophysiologic mechanism of nephrotic syndrome is not yet known clearly. At least in some cases, certain 'circulating factors' are thought to increase the glomerular protein permeability. Considering the systemic effect of the circulating factor on peritoneal membrane, we evaluated the loss of protein through peritoneal membrane in patients on peritoneal dialysis due to the end stage renal disease (ESRD) caused by steroid resistant nephrotic syndrome (SRNS). Methods : We retrospectively reviewed the medical records of 26 pediatric patients on peritoneal dialysis ensued during the period from 2001 to 2007 at our clinic. Twelve patients had SRNS, while 14 patients had ESRD caused by the congenital anomalies of urinary system. Results : While the other parameters including nPNA indicating the adequacy of protein intake were similar between the two groups, serum albumin was lower in SRNS patients than the non-SRNS patients (
Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.
Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
Objectives: The purpose of this field case report is 1) to analyze the community's strategy and performance in responding to infectious diseases through the case of COVID-19 infectious disease crisis response of Daegu Metropolitan City, and 2) to interpret this case using governance theory and infectious disease response governance framework. and 3) to propose a strategic model to prepare for future infectious disease outbreaks of the community. Methods: Cases of Daegu Metropolitan City's infectious disease crisis response were analyzed through researchers' participatory observations. And review of OVID-19 White Paper of Daegu Metropolitan City, Daegu Medical Association's COVID-19 White Paper, and literature review of domestic and international governance, and administrative documents. Results: Through the researcher's participatory observation and literature review, 1) establishment of leadership and response system to respond to the infectious disease crisis in Daegu Metropolitan City, 2) citizen's participation and communication strategy through the pan-citizen response committee, 3) cooperation between Daegu Metropolitan City and governance of public-private medical facilities, 4) decision-making and crisis response through participation and communication between the Daegu Metropolitan City Medical Association, Medi-City Daegu Council, and medical experts of private sector, 5) symptom monitoring and patient triage strategies and treatment response for confirmed infectious disease patients by member of Daegu Medical Association, 6) strategies and implications for establishing and utilizing a local infectious disease crisis response information system were derived. Conclusions: The results of the study empirically demonstrate that collaborative governance of the community through the participation of citizens, private sector experts, and community medical facilities is a key element for effective response to infectious disease crises.
Background : The level of imposed work of breathing (WOB) is important for patient-ventilator synchrony and during weaning from mechanical ventilation. Triggering methods and the sensitivity of demand system are important determining factors of the imposed WOB. Flow triggering method is available on several modern ventilator and is believed to impose less work to a patient-triggered breath than pressure triggering method. We intended to compare the level of imposed WOB on two different methods of triggering and also at different levels of sensitivities on each triggering method (0.7 L/min vs 2.0 L/min on flow triggering ;
Background : The Sequential Organ Failure Assessment (SOFA) score can help to assess organ failure over time and is useful to evaluate morbidity. The aim of this study is to evaluate the performance of SOFA score as a descriptor of multiple organ failure in critically ill patients in a local unit hospital, and to compare with APACHE III scoring system. Methods : This study was carried out prospectively. A total of ninety one patients were included who admitted to the medical intensive care unit (ICU) in Chuncheon Sacred Heart Hospital from May 1 through June 30, 2000. We excluded patients with a length of stay in the ICU less than 2 days following scheduled procedure, admissions for ECG monitoring, other department and patients transferred to other hospital. The SOFA score and APACHE III score were calculated on admission and then consecutively every 24 hours until ICU discharge. Results : The ICU mortality rate was 20%. The non-survivors had a higher SOFA score within 24 hours after admission. The number of organ failure was associated with increased mortality. The evaluation of a subgroup of 74 patients who stayed in the ICU for at least 48 hours showed that survivors and non-survivors followed a different course. In this subgroup, the total SOFA score increased in 81% of the non-survivors but in only 21% of the survivors. Conversely, the total SOFA score decreased in 48% of the survivors compared with 6% of the non-survivors. The non-survivors also had a higher APACHE III score within 24 hours and there was a correlation between SOFA score and APACHE III score. Conclusion : The SOFA score is a simple, but effective method to assess organ failure and to predict mortality in critically ill patients. Regular and repeated scoring enables patient's condition and clinical course to be monitored and better understood. The SOFA score well correlates with APACHE III score.
Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations (