• Title/Summary/Keyword: Patient Monitoring Device

Search Result 96, Processing Time 0.023 seconds

Implementation of Medical Device Integration Module for Integrated Patient Monitoring System

  • Park, Myeong-Chul;Jung, Hyon-Chel;Choi, Duk-Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.79-86
    • /
    • 2017
  • In this paper, we implement a common module that can integrate multiple biometric information for integrated patient monitoring system. Conventional biomedical instruments have many devices attached to each patient, making it difficult to monitor abnormality signs of many patients in real time. In this paper, we propose a module for an integrated monitoring system that can perform centralized monitoring using a common module that integrates multiple measurement devices. A protocol for sending and receiving packets between the measuring device and the common module is designed, and the packets transmitted through the network are stored and managed through the integrated monitoring system and provide information to various users such as medical staff. The results of this study are expected to contribute to the management of patients and efficient medical services in hospitals.

Real-time urine monitoring system for intensive care patient using optical sensor (광센서를 이용한 실시간 중환자 요량감시 장치)

  • Kim, Jong-Myoung;Lee, Jin-Young;Hong, Joo-Hyun;Lim, Seung-Woon;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.81-85
    • /
    • 2008
  • This paper addressed real-time urine monitoring device for intensive care patients. The device was developed to detect and count each urine drop using optical sensor and calculate the current urine output volume and its hourly rate. In experiment, the water volume scale of drainage bottle was observed and compared with the count of the device so that the volume of each drop was found to vary with the dropping rate per minute. From this measurement, the relationship equation was derived to estimate the total water volume from the drop rate (correlation coefficient : r= 0.99). The developed device could be applied to count patient's urine drop successfully. Therefore, this device can be used to monitor intensive care patient's urine status in real-time.

Implementation of ISO/IEEE 11073-10404 Monitoring System Based on U-Health Service (유헬스 서비스 기반의 ISO/IEEE 11073-10404 모니터링 시스템 구현)

  • Kim, Kyoung-Mok
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.6
    • /
    • pp.625-632
    • /
    • 2014
  • The u-health service is using portable device such as smart device and it consists of small computing device. The u-health service carry out same performance with desktop computer. We designed message structure based on Bluetooth HDP. This message structure is used to transmit patient's biometric data on the smart device of medical team, patient and family over the mobile network environment. ISO/IEEE 11073 PHD standard was defined based on the method of communication between the agent and the manager. And We are confirmed the reliable transmission of biometric data at the smart device by implementing the android OS based patient information monitoring application to check the status of patient for medical team, patient and family.

Development of HL7 V 2.5 Middleware for Patient Monitoring Device (환자감시장치를 위한 HL7 V2.5 미들웨어의 개발)

  • Kim, Hyung-Hoi;Cho, Hune;Tran, Tung;Hong, Hae-Sook;Kim, Hwa-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1680-1687
    • /
    • 2007
  • A hospital room has multiple patient monitoring devices at the bedside to monitor his or her status. However, vital sign monitors, ventilator and other bedside devices are made by a variety of different manufacturers and often cannot easily interface to the hospital information system. Medical environments incorporate complex and integrated data networks to transfer vast amounts of patient information, such as images, waveforms, and other forms of digital data. Hence, to assure interoperability of images, waveforms and patient data, Health Level Seven (HL7) was developed as an international standard to facilitate the communicating and storing of medical data. In this study, we developed middleware capable of receiving data from mCare 300 vital signs monitoring devices and converting the data to HL7 data format. The HL 7 middleware streamline clinical workflow and support patients. Therefore, clinical expertise are empowered to respond to dynamic healthcare situation as soon as they emerged, and consequently quality of care while helping to reduce the length of a patient's stay in a hospital.

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

Implementation of Patient Monitoring System based on Mobile Healthcare (모바일 헬스케어 기반의 환자 모니터링 시스템 구현)

  • Kim, Kyoung-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.1-10
    • /
    • 2012
  • In this paper, we propose an patient monitoring system which is suitable for mobile healthcare system. The mobile healthcare system is using portable device such as smartphone and it consists of small computing device. The mobile healthcare system is carry out same performance with desktop computer. We designed medical message structure based on TinyOS to transmit patient's biometric data on the smartphone of medical team, patient and family over the mobile carrier environment, and ported successfully in HBE-Ubi-ZigbeX using NesC. And We confirmed reliable transmission of biometric data on the smartphone by implementing the Android OS based patient information monitoring application to check the status of patient for medical team, patient and family.

A design of Software 2D BitBLT Engine based on RTOS (RTOS 기반의 소프트웨어 2D BitBLT 엔진의 설계)

  • Kim, Bong-Joo;Hong, Jiman
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.4
    • /
    • pp.35-41
    • /
    • 2014
  • In this paper, we proposed the implementation of software-based 2D BitBLT engine on the pSOS operating system and the operation of the BitBLT engine on patient monitoring device was verified. To verify the proposed method on the patient monitoring device, we designed prototype PCB board, and verified the operation. We designed the motherboard by using ARM9-based CPU. Because hardware-based BitBLT module was replaced with software-based one, CPU load problem was weighted. To solve this problem, w changed 400Mhz processor instead of 200Mhz processor. We implemented 2D BitBLT kernel module as a device driver which is one of the key elements of a graphics controller GUI in patient monitoring device.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

Patient Monitoring System Base on U-Healthcare (U-Healthcare 기반의 환자 모니터링 시스템)

  • Jung, Won-Soo;Oh, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7B
    • /
    • pp.575-582
    • /
    • 2008
  • The existing patient monitoring system when the patient want own information. The patient confirm information through the medical institution. But the patient monitoring system based on the U-Healthcare, the patient always confirms own information through the mobile device including rfid reader. The patient need RFID middleware design to provide wanting service when the RFID reader read patient's tag information. The RFID middleware is consisted of RFID module, ARM processor and RS-232 interface. The RFID module is used to be inputted user information and RS-232 interface pass information by RFID middleware. Also, This system is embodied by specific patient monitoring system using embedded exclusive use ARM processor. In this paper introduces concept and action principle of RFID middleware and embodied patient monitoring system that use Qt.

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.