• 제목/요약/키워드: Patient Flow

검색결과 622건 처리시간 0.028초

침감(鍼感) 및 침향(鍼響)에 대한 문헌적(文獻的) 고찰(考察) (A Study of Literature Review on Needling Sensation and the Flow of the Needling Sensation)

  • 김성철
    • Journal of Acupuncture Research
    • /
    • 제18권3호
    • /
    • pp.201-214
    • /
    • 2001
  • Objective : To study needling sensation and the flow of the needling sensation the ancient and the present literatures were reviewed. Results : 1. The needling sensation was getting the Qi and a normal reaction of acupuncture. 2. The flow of the needling sensation was promoted the Qi and normalized the flow of the Qi 3. The needling sensation of a patient expressed soreness, distension, heaviness, numbness, tingling, flushing, fervor, chill, itching, and so forth. 4. The needling sensation of a patient expressed simple or complex syndrome. 5. The needling sensation of a doctor expressed objectively more than the needling sensation of a patient in the hand feeling of a doctor. 6. The doctor was compared good needling sensation and bad needling sensation. 7. The needling sensation and the flow of the needling sensation were processed continuously. 8. The needling sensation and the flow of the needling sensation were connected with a nervous system and expressed variously in the anatomical structure and hand acupuncture tenchnique.

  • PDF

환자흐름에의 영향요인 (The Factors Affecting Patient-Flow)

  • 박재용
    • 보건행정학회지
    • /
    • 제3권2호
    • /
    • pp.27-80
    • /
    • 1993
  • It is widely known that patients' utilization pattern for medical care facilities and the patientflow are influenced by multi-factors, such as demographic characteristics, structural characteristics of society, socio-psychological characteristics(value, attitude, norms, culture, health behavior, etc.), economic characteristics(income, medical price, relative price, physician induced demand, etc.), geographical accessibility, systematic characteristics(health care delivery system, payment methods for physician fees, form of health care security, etc.), and characteristics of medical facilities(reliability, quality of medical care, convenience, kindness, tec.). This study was conducted to research the mechanism of patient-flow according to changes of health care system(implementation of national health insurance, health care referral system and regionalization of health care utilization, etc.) and characteristics of medical facilities(ownership of hospital, characteristics of medical services, non-medical characteristics, etc.). In this study, the fact could be ascertained that the patient-flow had been influenced by changes of health care system and characteristics of medical facilities.

  • PDF

구개열 환자에서의 구강인두압력 및 공기유량에 관한 음성학적 특징 (CHARACTERISTICS OF OROPHARYNGEAL AIR PRESSURE, AIRFLOW IN CLEFT PALATE PATIENTS)

  • 백진아
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.13-20
    • /
    • 2006
  • The articulation disorders associated with velopharyngeal insufficiency (VPI) in cleft palate patients are interested to clinicians particularly. The purpose of this study was to investigate mainly the oropharyngeal air pressure and overall air flow in cleft palate patients. The pressure-measuring catheter was positioned at the midportion of the oropharyngeal cavity with a facial mask. Test words were composed of 9 meaningless polysyllabic words and 17 meaningful words. Aerophone II and Nasometer II were used to measure peak air pressure, mean air pressure, maximum flow rate, volume, phonatory flow rate, nasalance. The data shows that airflow of the cleft palate patient group were higher than those of the control group. Intraoral air pressure of the cleft palate patient group was lower than those of the control group. The first vowel formant and first Bandwidths of the cleft palate patient group were higher than those of the control group.

류머티스 환자 이력 데이터에 기반한 환자 플로우 모니터링 시스템 (Patient Flow Monitoring System based on Rheumatic Patient History Data)

  • 김준우;이상철;박상찬
    • 한국콘텐츠학회논문지
    • /
    • 제14권10호
    • /
    • pp.10-19
    • /
    • 2014
  • 최근 병원에서 수집되는 데이터를 전자적으로 저장, 관리 및 공유하기 위하여 병원정보시스템이 널리 활용되고 있다. 이러한 시스템들은 현대 병원들의 업무 효율성 제고에 크게 기여해왔으나, 건강관리 서비스 제공자들의 의사 결정을 지원하기 위해서는 수집된 환자 관련 데이터를 적절히 가공하고 재사용하는 것이 필요하다. 특히, 본 논문은 만성 질환과 관련된 외래진료과 운영관리를 위한 환자 플로우 모니터링을 제안하고, 이와 관련된 사항들에 대해 토의하고자 한다. 제안하는 시스템은 환자 이력 데이터에 프로세스 마이닝 기법을 적용하여 추출한 표준 프로세스 모형 및 여러 가지 평가 지표들을 시각화하며, 이를 통해 관리자들은 외래진료과의 운영을 평가하고 개선할 수 있다. 본 논문에서는 환자 플로우 모니터링 시스템을 류머티스 진료과에 적용하였으며, 아이패드 기기에 최적화된 프로토타입 시스템을 예시로 보이고자 한다.

도플러 초음파 기기를 이용한 편측 부전마비성 뇌졸중 환자와 정상인의 말초 혈류 비교 연구 (Comparison of Peripheral Blood Flow in Post-Stroke Hemiparetic Patients and Normal Person with Doppler Ultrasonography)

  • 한덕진;방창호;세르게이 김;배영민;신새론;양충용;이인
    • 동의생리병리학회지
    • /
    • 제23권6호
    • /
    • pp.1491-1496
    • /
    • 2009
  • Stroke is usually associated with the cerebral blood flow of the central nervous system. However, studies concerning the effects of neurologic sysmptoms induced from stroke on the peripheral blood flow has not taken place sufficiently. To ascertain the feasibility of a blood flow meter adopting to use doppler ultrasonogrphy, under the prospect that hemiparesis induced from stroke may have effect on the peripheral blood flow, the peripheral blood flow velocity was observed. The control group made up of healthy people without any factors capable of effecting the peripheral blood flow velocity, and patient group which consist of hemiparetic people induced from stroke, were recruited. Volumes of recruitment are 21 persons in the patient group, and 29 persons in the control group, but the final numbers of people are 17 and 21 respectively because of the inconsistancy in the method of the test. The non-invasive method of Doppler effect of Ultrasound was used to measure the blood flow velocity. The blood flow velocity in the peripheral part of left and right fourth fingers:dorsal branches of proper palmar digital artery to dorsum of distal phalanges, was measured in the control group and patient group through Doppler Ultrasound. In comparison of the control group and the patient group, the systolic blood flow velocity from the peripheral part of the upper extremity was lower in the patient group than that of the control group. According to such results, it is concluded that hemiparesis induces the reduction of the peripheral blood flow velocity in the systolic phase.

실제 혈관 형상 및 혈액 특성을 고려한 경동맥 내 혈액 유동에 대한 수치해석 연구 (A NUMERICAL ANALYSIS ON BLOOD FLOOD FLOW INSIDE A CAROTID ARTERY WITH THE PATIENT SPECIFIC ARTERIAL GEOMETRY AND BLOOD RHEOLOGY DATA)

  • 이상혁;정슬기;허남건;조영일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.224-227
    • /
    • 2010
  • In the present study, the characteristics of blood flow inside a carotid artery numerically investigated with shear rate specific blood viscosity. To simulate the blood flow with a patient-specific arterial geometry, the geometry of a carotid artery was constructed from 2D rain MRA data. The measured data of blood flow velocity at the common carotid artery were used as boundary conditions of the simulation. For the blood rheology data to be used in the simulation, the patient specific blood viscosity over the whole ranges of shear rate was obtained using $BioVisco^{TM}$. From the numerical results of the blood flow in the carotid artery, the increase of blood viscosity and the decrease of wall shear stress could be found in the carotid bifurcated region, more specifically at the post-plaque dilated region. These characteristics of blood viscosity and wall shear stress can be used more precisely and efficiently to predict the region vulnerable to plaque growht or thrombosis on top of the plaque.

  • PDF

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

Photo-Plethysmography를 이용한 정상과 재접합 수지 혈류량의 비교 (Comparison of normal and replantation digital blood flow using photo-plethysmography)

  • 남기창;김성우;나동균;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.322-324
    • /
    • 2004
  • Up to the present, digital replantation patients has appealed different symptoms due to blood circulatory failure. But, the level of blood circulatory failure has been evaluated only by clinical symptoms, or angiography. According to the cases of digit replantation is increasing, then objective evaluation methods of the level of blood circulation failure is needed other than patient's subjective symptoms and complaints. Although angiography, doppler, electromagnetic flowmeter, laser blood flowmeter, mechanical blood flowmeter has been used for the evaluation of the blood circulatory failure, the result was affected by time, place, surrounding temperature, patient's body temperature, and even emotion. Therefore, it is pointed out with lack of availability, feasibility and reproducibility. Thus, we compared digital blood flow of dominant hand to non dominant hand, and replanted fingers to opposite normal fingers from developed photo-plethysmography. The average digital blood flow showed no difference in normal digits each other, but, replanted digits showed average of 53% (9 - 100 %) compare to opposit normal digits. As it measure relative blood flow for circulatory failure of tissue such as fingers and toes more sensitively, reliably. In conclusion, it is expected that photo- plethysmography will be very useful for diagnosis, curative effect, prognosis of blood circulatory failure in digital replantation patient.

  • PDF

가압식 비침습적 대뇌 혈류 증가 장치의 구현 (Implementation of Non-Invasive Pressurized Cerebral Perfusion Platform)

  • 이진;유형곤;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.171-174
    • /
    • 2017
  • 다음은 요뇌경색의 대표적인 치료법과 예방법중 하나는 대뇌혈류를 증가하는 방법이다. 대뇌 부위로 가는 혈류량을 우회적으로 증가시켜 최종대뇌 손상부위를 최소화 하는 것을 목표로 한다. 이와 같은 대뇌혈류를 증가시키는 방법은 약물에 의한 치료방법과, 수술에 의한 방법 등 칩습적으로 행해져왔다. 하지만 이러한 침습적인 방법은 환자에게 수술의 부담을 주며 합병증 등의 위험에 노출되어 있는 단점이 있다. 본 논문에서는 이러한 침습적인 치료방법의 단점을 보완하고자 비침습적 대뇌혈류증가 장치를 제안한다. 기존의 대뇌 혈류 증가 장치의 단점을 보완하기 위해 가압식 측정법을 적용하여 환자의 사지 혈압을 정확하게 측정하고 사지압박을 실시하여 대뇌부위로 가는 혈류량을 우회적으로 증가시켜 혈류증강 치료를 실시한다. 이는 기존의 침습적 대뇌혈류증강 치료와 비교하여 합병증의 우려가 없고 환자에게 부담을 주지 않으며 대뇌혈류량을 의미 있게 증가시키기 때문에 환자에게 선택적으로 사용될 수 있다.

  • PDF

위축성 비염 환자에서 성상신경절 블록의 치료효과 -증례 보고- (Stellate Ganglion Blocks in Atrophic Rhinitis)

  • 김승준;이우창;장원석;윤덕미
    • The Korean Journal of Pain
    • /
    • 제14권2호
    • /
    • pp.231-233
    • /
    • 2001
  • Atrophic rhinitis is characterized by mucosal atrophy, bony absorption, persistent fetid odor and resistance to medical and surgical treatment. Stellate ganglion block (SGB) can be used as a therapeutic modality by improving the regional blood flow through sympathetic blockade. We present a case of a 57 year-old male patient who had been treated unsuccessully for atrophic rhinitis for several years by surgical and conservative measures. The patient presented at our pain clinic with shoulder pain and received stellate ganglion block once or twice a week. He received more than 75 SGBs in addition to the routine conservative treatment for atrophic rhinitis. As the number of blocks performed increased, the patient demonstrated subjective symptom relief. We measured regional mucosal blood flow using a laser doppler flowmeter after the 28th, 63rd and 75th blocks. Nasal mucosal blood flow was improved by 4.9%, 28.8% and 36.3% respectively. We also were able to observe the recovery of mucosal atrophy to an almost normal level by nasal endoscopy. The patient is currently free of symptoms and is being followed up on an outpatient bases.

  • PDF