• Title/Summary/Keyword: Patient' body movement

Search Result 128, Processing Time 0.026 seconds

Study on The Development of A New Whole Body Fame

  • Chung, Jin-Bum;Suh, Tae-Suk;Chung, Won-Kyun;Choe, Bo-Young;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.136-137
    • /
    • 2002
  • We have been researching upgrade version of a stereotactic whole body frame, used for evaluating daily setup accuracy of the patient positioning during fractionated extra-cranial stereotactic radiotherapy. Currently, we are focusing on the development of a new stereotactic whole body frame, and then will handle organ movement produced by breathing at the next stage. MeV-Green is chosen for the best immobilizer possible and the epoxy board is for the frame with the dimension of 110 em in length, 50 cm in width in order to maximize transmission rate of the beam from lateral or posterior direction and to fit CT and PET scanners with an aperture of 55 cm at least. The key point of an upgraded stereotactic whole body frame will be set on the collision-free rotation of the gantry with the frame, and the development of the checking structure for the daily patient repositioning regarding internal target.

  • PDF

Electrical Stimulation System Design for Pharyngeal Dysfunction of Stroke Patients (뇌졸중 환자의 인두기능 회복을 위한 전기자극기 설계)

  • 김성민;배하석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1232-1235
    • /
    • 2004
  • The purpose of this study is to design electrical stimulation system for pharyngeal dysfunction(dysphagia) in stroke patients. Pharyngeal muscle group activity is important, because contracting muscles provide the driving force at the initiation of the swallow and generate the pressure gradients necessary for bolus movement into the esophagus. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation can be divided into the body stimulation and electrodes. The body stimulation is divided again into frequency counter, time control and current measurement part. These parts are to control the current intensity, frequency and stimulating time. And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with the stroke patient who has swallowing disorder. The videofluoroscopy was used for the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient can be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.

  • PDF

The Effect of Seat Incline Angle in Hemiplegic Patients' Standing up Training

  • Sim, Woo Sang;Jung, Kwang Tae;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.493-501
    • /
    • 2016
  • Objective: This study analyzes the effect of angle conditions of rehabilitation equipment used for supporting hemiplegic patients on their rehabilitation training for standing action. The study was performed by adjusting the rear angle of seat inclination through a motion analysis. Background: Owing to a loss of muscle rigidity and degradation of muscle control ability, hemiplegic stroke patients suffer from asymmetrical posture, abnormal body balance, and degraded balance abilities due to poor weight-shifting capacity. The ability to shift and maintain one's weight is extremely essential for mobility, which plays an important role in our daily life. Thus, to improve patients' ability to maintain weight evenly and move normally, they need to undergo orthostatic and ambulatory training. Method: Using a motion analysis system, knee movements on both hemiplegic side and non-hemiplegic side were measured and analyzed in five angles ($0^{\circ}$, $10^{\circ}$, $30^{\circ}$, $50^{\circ}$, $70^{\circ}$) while supported by the sit-to-stand rehabilitation equipment. Results: The knee movements on both sides increased as the angle increased in angle support interval to support a hemiplegic patient's standing up position. In standing up interval, a hemiplegic patient's knee movement deviations on both sides decreased, and the movement differences between hemiplegic and non-hemiplegic legs also decreased as the angle increased. Conclusion: The results of this study showed that the rehabilitation effectiveness increases as the angle increases, leading to a balanced standing posture through the decrease of movement difference between hemiplegic and non-hemiplegic sides and an improved standing up ability through the increase of knee movement on both sides. However, angles higher than $50^{\circ}$ didn't provide a significant effect. Therefore, a support angle under $50^{\circ}$ was proposed in this study. Application: The results of this study are expected to be applicable to the design of sit-to-stand support equipment to improve the effectiveness of the rehabilitation process of hemiplegic patients.

The Effect of Youndamsagan-tang on a Case of Septic Knee: A Case Report (용담사간탕을 투여한 화농성 슬관절염 환자의 치검 1례)

  • Kang Dae Hee;Kim Young Dal;Kim Chang Nyun;Min Ji Yeun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.6
    • /
    • pp.1547-1551
    • /
    • 2003
  • This study was carried out to characterized the effect of Youndamsagan-tang on a Case of Septic Knee. After we gave Youndamsagan-tang to a patient of septic knee, we examined not only symptom of patient but also the thickness and circumference of knee, the change of WBC, ESR, body temperature, VAS. As admission time passes, the pain, flare, swelling and movement of left-side knee joint were improved. The thickness and circumference of knee joint were decreased, and the count of WBC, ESR were decreased. And patient's pain by VAS was subsided. From the above result, administration of Youndamsagan-tang reduces the progressing of pain, flare, swelling and movement in knee joint.

The Effect of Watsu Therapy on Muscle Tone in Adult Hemiparesis Patient After Stroke (Watsu 치료가 뇌졸중 이후 성인 편부전마비환자의 근긴장도에 미치는 영향)

  • Chon, Seung-Chul
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.2
    • /
    • pp.46-56
    • /
    • 2004
  • The purpose of this study was to investigate the effect of watsu therapy on muscle tone in adult hemiparesis patient after stroke. The subject was a 66 year old patient with left hemiparesis whose self gait was independent with minimal assist. The subject was ambulatory with some degree of limitation and demonstrated a little tremor and asymmetry in the body. A multiple treatment design(A-B-C-B) for a single-subject research was used for this study. The watsu therapy consisted of basic moves, head cradle, underfar leg, near leg cradle in watsu I (transition flow), for 25 minutes, which lasted 12 sessions for a total 21 sessions. A baseline was conducted for a first time and a general ROM exercise was conducted after the first watsu therapy. Tone assessment scale was tested : 1. posturing at rest 2. response to passive movement 3. associated reaction Comparing to the baseline and general ROM exercise, The results showed that the watsu therapy had some positive effects on improvement of three tests and there was a more positive effects of both response to passive movement and associated reaction.

  • PDF

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Dental needle foreign body in the neck: a case report

  • Mohammed, Hassen;Shallik, Nabil;Barsoum, Mina;Abdulla, Majid Al;Dogan, Zynel;Ahmed, Hassan Haidar;Moustafa, Abbas
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.2
    • /
    • pp.83-87
    • /
    • 2020
  • Foreign body (FB) ingestion is commonly seen in the ear nose and throat (ENT) field, with different presentations and sequelae. FBs can arrest in the upper aerodigestive tract or continue further down into either the airway tract to the bronchus or the digestive tract to the intestines. The pathway of an FB depends on the size and shape of the FB and how sharp its edges are. Since the 20th century, the use of disposable stainless-steel needles in the oral cavity has proven to be an effective and safe method for performing various intraoral procedures like dental infiltration or a root canal wash. Complications from their use are rare. Generally, dental needle breakages are caused by patients biting the needle, incorrect injection techniques, or inadequate preventative measures. The sudden movement of a patient during a procedure is one of the most common causes of breakage. Occasionally, needles are swallowed during dental procedures such as a root canal. Here, we report a case of a patient that swallowed a broken needle during a dental procedure. A few days later, the patient presented with neck pain, swelling, and a FB sensation. When the patient presented, she claimed that her symptoms had onset after consuming a meal containing duck meat. Initially, the patient was diagnosed as having ingested a duck bone. However, intraoperatively, the FB was discovered to be an injection needle that had migrated from the throat to the neck.

The clinical study on 1 case of essential tremor patient (본태성 진전(震顫)을 주(主) 증상(症狀)으로 한 환자(患者) 1례(例))

  • Min, Kyoung-Jik;Kim, Seok-Hwan;Jung, In-Chul;Lee, Sang-Ryong
    • Journal of Haehwa Medicine
    • /
    • v.16 no.2
    • /
    • pp.281-288
    • /
    • 2007
  • Tremor is a rhythmic, involuntary muscular contraction characterized by oscillations (to-and-fro movements) of a part of the body. Essential tremor is a 6-8 Hz tremor that is of variable amplitude. It is aggravated by posture and movement and relieved by rest and alcohol. Most affected part are the arms, head and vocal apparatus. The purpose of this study is to show a case of tremor patient with essential tremor improved by oriental medical treatment. The patient was 71-year-old woman who featured essential tremor and at the same time complained general body weakness, nausea, and anorexia. She was treated by oriental medicine with acupuncture, herb medication, and Korean psychotherapy; Eejeong-byunki, Jiun-goron. The features of essential tremor was reduced after taking oriental medical therapy. This result suggested that the oriental medical therapy can be effective for treating essential tremor.

  • PDF

Diagnosis and Treatment of Patient with Radiopaque Material in Temporomandibular Joint : Case Report (측두하악관절 내에 방사선 불투과성 물질을 가지 환자의 진단과 치료 : 증례보고)

  • Yang, Dong-Gul;Choi, Jong-Hoon;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 2000
  • A 69-year-old male pateint was admitted for discomfort on right temporomandibular joint during opening, closing and chewing that started few months ago. The patient had no special medical history except for lung tuberculosis approximately 30 years ago and nothing specific appeared on a physical exam taken 2 months ago. Clinical tests show that mouth opening of 53mm which was normal and no joint sound, deviation, pain during opening. But tenderness to palpation on Rt masseter muscle and pain existed on Rt temporomandibular joint during loading test on the right joint. No pain existed during resistance test and protrusion and range of lateral movement was normal. Rt temporomandibular joint was not swollen and no palpable mass was observed. No previous trauma history to the face existed. On X-ray calcific material existed in the joint cavity and on CT image, approximately 2mm sized calcific material appeared on the Rt temporomandibular joint but no change in bone appeared on the condyle nor the temporal bone. The patient was diagnosed as loose body, and the symptoms were relived after 2 physical therapies and is under regular check ups. The purpose of this case is to review disease that cause loose bodies.

  • PDF