• Title/Summary/Keyword: Patency

Search Result 398, Processing Time 0.045 seconds

Radionuclide (Tc-99m) Hysterosalpingography for Evaluation of Fallopian Tube Patency (동위원소(Tc-99m HAM)를 이용한 난관 조영술)

  • Park, Won;Kim, Chong-Soon;Park, Chang-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.207-211
    • /
    • 1987
  • A prospecitive study was performed to evaluate the efficacy of Radionuclide Hysterosalpingography (RNHSG), that was modified by McCalley, et al. for the evaluation of fallopian tube. Using spontaneous migration of Tc99m labelled human albumin microsphers (HAM) and images got with Gamma camera, the study was made in 20 gynecological patients (44 tubes) in an effort to confirm the anatomical patency or obstruction as well as functional one at the Department of Obstetrics and Gynecology, National Medical Center from January 1, 1986 to July 31, 1986. The efficacy was also compared with that of contrast hysterosalpingography and surgical observation. Results obtained were as follows; 1) The Radionuclide Hysterosalpingography appeared to be a simple and accurate procedure as a mean with which anatomical tubal patency, as well as functional patency can be detected, although it's some limit in showing anatomical details of uterine cavity and tubes in comparison with contrast hysterosalpingography. 2) The predicted value of tubal obstruction was 82.4%. and that of tubal patency was 88.9% respectively. Overall efficacy (percent of tube correctly classified) of Radionuclide Hysterosalpingography was 88.6%. 3) There was no nuclide related complication during and after the procedure.

  • PDF

Clinical Results of Arteriovenous Fistulas Constructed Using Autologous Vessels in End-Stage Renal Disease Patients on Hemodialysis

  • Kim, Ki Tae;Ryu, Jae Wook;Seo, Pil Won;Ryu, Kyoung Min
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.122-129
    • /
    • 2018
  • Background: For hemodialysis patients with end-stage renal disease (ESRD), it is important to construct an efficient vascular access with a superior patency rate. This study investigated the factors influencing the efficiency of arteriovenous fistulas (AVFs) constructed using an autologous vessel and evaluated the necessity of ultrasonography as a preoperative tool for AVF construction. Methods: A retrospective analysis was performed of 250 patients in whom an AVF was constructed using an autologous vessel due to ESRD at our institution from January 2009 to April 2016. Results: The 1-, 3-, and 5-year patency rates for all subjects were 87.6%, 85.6%, and 84.4%, respectively. The patients who underwent a preoperative evaluation of their vessels via ultrasonography had better patency rates than those who did not. Superior patency rates were found in patients under 65 years of age or with an anastomotic vein diameter of 3 mm or more. The 1-year patency rate and the diameter of the anastomotic vein showed a positive relationship. Conclusion: Ultrasonography is strongly recommended for AVF construction, and efforts should be made to increase the patency rate in patients over 65. Superior clinical results can be expected when an AVF is made using an autologous vessel with an anastomotic vein diameter of at least 3 mm.

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

Outcomes and Patency of Complex Configurations of Composite Grafts Using Bilateral Internal Thoracic Arteries

  • Shih, Beatrice Chia-Hui;Chung, Suryeun;Kim, Hakju;Chang, Hyoung Woo;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun;Kim, Jun Sung
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.64-72
    • /
    • 2020
  • Background: It is generally agreed that using a bilateral internal thoracic artery (BITA) composite graft improves long-term survival after coronary artery bypass grafting (CABG). Although the left internal thoracic artery (LITA)-based Y-composite graft is widely adopted, technical or anatomical difficulties necessitate complex configurations. We aimed to investigate whether BITA configuration impacts survival or patency in patients undergoing coronary revascularization. Methods: Between January 2006 and June 2017, 1,161 patients underwent CABG at Seoul National University Bundang Hospital, where the standard technique is a LITA-based Y-composite graft with the right internal thoracic artery (RITA) sequentially anastomosed to non-left anterior descending (LAD) targets. Total of 160 patients underwent CABG using BITA with modifications. Their medical records and imaging data were reviewed retrospectively to investigate technical details, clinical outcomes, and graft patency. Results: Modifications of the typical Y-graft (group 1, n=90), LITA-based I-graft (group 2, n=39), and RITA-based composite graft (group 3, n=31) were used due to insufficient RITA length (47%), problems using LITA (28%), and target vessel anatomy (25%). The overall 30-day mortality rate was 1.9%. Among 116 patients who underwent computed tomography or conventional angiography at a mean interval of 29.9±33.1 months postoperatively, the graft patency rates were 98.7%, 95.3%, and 83.6% for the LAD, left circumflex artery, and right coronary artery territories, respectively. Patency rates for the inflow, secondary, and tertiary grafts were 98.2%, 90.5%, and 80.4%, respectively. The RITA-based graft (group 3) had the lowest patency rate of the various configurations (p<0.011). Conclusion: LITA-based Y composite graft, showed satisfactory clinical outcomes and patency whereas modifications of RITA- based composite graft had the lowest patency and 5-year survival rates. Therefore, when using RITA-based composite graft, other options should be considered before proceeding atypical configurations.

A COMPARISON OF THE IRRIGATION SYSTEMS IN CALCIUM HYDROXIDE REMOVAL (근관세정 방법에 따른 수산화칼슘 제재의 제거 효율 비교)

  • Eun, Jae-Seung;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.508-514
    • /
    • 2009
  • The purposes of this study were to compare the efficacy of irrigation systems by removing a calcium hydroxide $(Ca(OH)_2)$ paste from the apical third of the root canal and the effect of the patency file. Sixty single rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with .04 taper ProFile to ISO #35. $Ca(OH)_2$ and distilled water were mixed and placed inside the root canals. The teeth were divided into 6 groups according to the root canal irrigation system and the use of patency file as follows: group 1 - conventional method: group 2 - $EndoActivator^{(R)}$: group 3 - $EndoVac^{(R)}$; group 4 - conventional method, patency: group 4 - $EndoActivator^{(R)}$, patency; group 6 - $EndoVac^{(R)}$, patency. All teeth were irrigated with sodium hypochlorite. After the root canal irrigation, the teeth were split in bucco-lingual aspect. Percentage of the root canal surface coverage with residual $Ca(OH)_2$ until 3 mm from working length was analyzed using Image Pro Plus ver. 4.0. Statistical analysis was performed using the One-way ANOVA, t-test and Scheffe's post-hoc test. Conventional groups had significantly more $Ca(OH)_2$ debris than $EndoActivator^{(R)}$, $EndoVac^{(R)}$ groups. There was no significant difference between $EndoActivator^{(R)}$ and $EndoVac^{(R)}$ groups. Groups with patency file showed more effective in removing $Ca(OH)_2$ paste than no patency groups. but. it was no significant difference. This study showed that $EndoActivator^{(R)}$ and $EndoVac^{(R)}$ systems were more effective in removing $Ca(OH)_2$ paste from the apical third of the root canal than conventional method.

Intraoperative Balloon Angioplasty Using Fogarty Artertial Embolectomy Balloon Catheter for Creation of Arteriovenous Fistula for Hemodialysis: Single Center Experience

  • Jin, Moran;Yoon, Young Chul;Wi, Jin Hong;Lee, Yang-Haeng;Han, Il-Yong;Park, Kyung-Taek
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.120-125
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the use of a Fogarty arterial embolectomy catheter (Fogarty catheter) in intraoperative balloon angioplasty of the cephalic vein, in order to determine its effect on the patency of arteriovenous fistulas (AVFs) created for hemodialysis access. Methods: A total of 156 patients who underwent creation of an AVF were divided into two groups, based whether a Fogarty catheter was used during AVF creation. Group A (89 patients) comprised the patients who underwent balloon angioplasty with a Fogarty catheter during the operation. Group B (67 patients) included the patients in whom a Fogarty catheter was not used during the operation. Patient records were reviewed retrospectively and documented. The patency rate was determined by the Kaplan-Meier method. Results: The records of 156 patients who underwent the creation of an AVF from January 2007 to October 2011 were included. The mean follow-up duration was $40.2{\pm}19.4$ months (range, 1 to 97 months). The patency rates in group A at 12, 36, and 72 months were $83.9%{\pm}3.9%$, $78.3%{\pm}4.6%$, and $76.3%{\pm}4.9%$, respectively, while the corresponding patency rates in group B were $92.5%{\pm}3.2%$, $82.8%{\pm}0.5%$, and $79.9%{\pm}5.7%$, respectively. The patency rates in group B were found to be slightly higher than those in group A, but the difference was not statistically significant (p=0.356). Conclusion: Intraoperative balloon angioplasty of the cephalic vein using the Fogarty catheter is a simple and easily reproducible procedure, and it can be helpful in increasing AVF patency in cases of insufficient runoff or a suboptimal cephalic vein.

20 Years-experience of 1000 Consecutive Vasovasostomy (20년간 정관정관문합술 1000례의 임상적 경험)

  • Seo, Ho-Kyung;Park, Nam-Cheol
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.25 no.2
    • /
    • pp.189-198
    • /
    • 1998
  • Since the male sterilization (vasectomy) has been performed on a large scale as an accepted family planning in Korea on 1980s and this, in turn, has been followed by an increase in the number of patients requesting vasovasostomy. We studies 1000 consecutive cases of vasovasostomy performed from January 1975 to July 1995 in Pusan National University Hospital. In this report, we are going to present serial studies of vasovasostomy through which we attempted to find out what factors are of impotence in influencing the successful outcome of vasovasostomy operation. We inquired the operative results data through the questionnaire and telephone interview with survey of medical records. A total of 259 cases was excluded due to the loss of follow-up. The overall patency and pregnancy rates of 741 cases were 86.9% and 51.1%, respectively. The age of man at the time of anastomosis ranged from 23 to 57 years old with an average of 34.9. The most frequent reason for requesting vasovasostomy was the desire to have more children (43.4%). The average obstructive interval was 60.6 months with range from 1 to 264 months. If the obstructive interval had been less than 5 years patency rate was 92.4% and pregnancy rate 64.8%, but 6 years or more 84.1% and 48.5% (p<0.01, p<0.01). Patency and pegnancy rates according to intraoperative vas fluid were 93.1% and 62.8% for presence and 83.7% and 53.1% for absence (p<0.01, p<0.05). Patency and pregnancy rates according to histologically proven sperm granuloma at vasectomy site were 87.7% and 49.2% for presence and 86.9% and 50.6% for absence (p>0.05, p<0.05). Patency and pregnancy rates were not significantly different between microscopic standard vasovasostomy (88.4%, 64.3%) and modified vasovasostomy (89.5%, 56.3%)(p>0.05, p>0.05). Both patency and pregnancy rates according to level of anastomosis were 89.8% and 59.8% in cases of straight vas and 91.5%, 60.1% in cases of convoluted vas (p>0.05, p>0.05). Patency and pregnancy rates according to the kind of suture materials were 91.5% and 56.2% for absorbable, 91.0% and 64.2% for non-absorbable and 93.3% and 53.3% for absorbable plus non-absorbable, respectively (p>0.05, p<0.05). Thus it is suggested that the important factor influencing the success rate of vasovasostomy is the interval of obstruction and vasal ooze with surgical skills.

  • PDF

Early Result of the Coronary artery Bypass Surgery (Analysis with the Postoperative Coronary artery Angiography) (관상동맥 우회수술의 조기성적 (술후 혈관조영술을 통한 분석))

  • 류경민;김삼현;박성식;류재옥;서필원
    • Journal of Chest Surgery
    • /
    • v.33 no.6
    • /
    • pp.487-493
    • /
    • 2000
  • Background: Early patency of the coronary artery bypass grafting is determined mainly by surgical technique and status of coronary artery. We analyzed the early result, focusing on the relationship between postoperative angiographic findings and the patency rate. Material and method: During the period of July 1997- August 1999, 86 cases of CABG were performed and the postoperative coronary artery angiography was done in 76 cases on postoperative day 7 to assess the graft patency. Result: Overall graft patency was 90.2% on the angiographic finding. Factors influencing the early graft occlusion were the surgeon's experience, small coronary artery size less than 1.5mm in diameter, coronary arteries related to pre-operative myocardial infarction, and local atheroma at the anastomosis site(p<0.001). Operative mortailty was 2.3%. Early recurrence of the symptom was 19.8% during the follow up period. Conclusion: We examined the postoperative coronary angiography and found that the surgeon's experience, small coronary artery size less than 1.5mm in diameter, bypass surgery on the coronary arteries related to pre-operative myocardial infarction, and local atheroma at the anastomosis site were the factors for the graft occlusion.

  • PDF

Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts

  • Han, Sun;Seo, Pil Won;Ryu, Jae-Wook
    • Journal of Chest Surgery
    • /
    • v.50 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • Background: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4-6-mm tapered and 6-mm straight forearm loop arteriovenous grafts. Methods: A total of 103 patients receiving forearm loop arteriovenous grafts between March 2005 and March 2015 were retrospectively analyzed and separated into 2 groups (group A, 4- to 6-mm tapered grafts, n=78; group B, 6-mm straight grafts, n=25). In each group, complications and patency rates after surgery were assessed. Results: Clinical characteristics and laboratory results, except for cerebrovascular disease history (group A, 7.7%; group B, 28.0%; p=0.014), were similar between the groups. No significant differences were found for individual complications. Kaplan-Meier survival analysis revealed no significant differences in 1-year, 3-year, and 5-year patency rates between groups (61.8%, 44.9%, and 38.5% vs. 62.7%, 41.1%, and 35.3%, respectively). Conclusion: We found no significant differences in complication and patency rates between the tapered and straight graft groups. If there are no differences in complication and patency between the two graft types, tapered grafts may be a valuable option for AVF formation in light of their other advantages.