• Title/Summary/Keyword: Paste Electrode

Search Result 255, Processing Time 0.028 seconds

A Study on Detection Characteristics of Cadmium and Lead for Bi Nanopowder-Labeled Electrode (비스무스 나노분말 표지 전극의 카드뮴/납 검출특성에 관한 연구)

  • Lee, Gyeoung-Ja;Kim, Hyoun-Jin;Lee, Hi-Min;Lee, Sang-Hoon;Lee, Min-Ku;Lee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.15 no.5
    • /
    • pp.393-398
    • /
    • 2008
  • Trace analysis of Cd and Pb at surface modified thick film graphite electrode with Bi nanopowder has been carried out using square-wave anodic stripping voltammetry (SWASV) technique. Bi nanopowder synthesized by gas condensation (GC) method showed the size of $50{\sim}100$ nm with BET surface area, $A_{BET}=6.8m^{2}g^{-l}$. For a strong adhesion of the Bi nanopowder onto the screen printed carbon paste electrode, nafion solution was added into Bi-containing suspension. From the SWASV, it was found that the Bi nanopowder electrode exhibited a well-defined responses relating to the oxidations of Cd and Pb. The current peak intensity increased with increasing concentration of Cd and Pb. From the linear relationship between Cd/Pb concentrations and peak current, the sensitivity of the Bi nanopowder electrode was quantitatively estimated. The detection limit of the electrode was estimated to be $0.15{\mu}g/l$ and $0.07{\mu}g/l$ for Cd and Pb, respectively, on the basis of the signal-to-noise characteristics (S/N=3) of the response for the $1.0{\mu}g/l$ solution under a 10 min accumulation.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

CO Adsorption on Three-Dimensional and Multilayered Platinum Electrode Prepared through Transfer Printing (전사 인쇄에 의한 3D와 다층의 Pt 전극의 CO가스 흡착)

  • Jeong, Yoon-Seo;Choi, You-Jeong;Shin, Jeong-Hee;Jeong, Young-Hun;Paik, Jong-Hoo;Yoon, Dae-Ho;Cho, Jeong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.232-236
    • /
    • 2020
  • Three-dimensional (3D) multilayered Pt electrodes were fabricated to develop a porous electrode using a pattern-transfer printing process. The Pt thin films were deposited using a transferred sputtering pattern having a 250 nm line width on the substrate, and the uniform line patterns were efficiently transferred using our proposed method. Temperature-programmed desorption (TPD) analyses were used to evaluate the porosity of the electrodes. It was possible to distinguish between two resolved maxima at 168 and 227 ℃, which could be described in terms of desorption reactions on the Pt (111) planes. The results of the TPD analysis of the 3D and multilayered Pt electrodes prepared through transfer printing were compared to those of an electrode fabricated through screen printing using a commercial Pt-carbon paste commonly used as porous electrodes. It was confirmed that the 3D multilayered electrodes exhibited a desorption concentration approximately 100 times higher than that of the Pt-carbon composite electrode, and the desorption concentration increased by approximately 0.02 mg/mol per layer. The 3D multilayered electrode effectively functions as a porous electrode and a catalyst.

The Fabrication of OTFT-OLED Array Using Ag-paste for Source and Drain Electrode (Ag 페이스트를 소스와 드레인 전극으로 사용한 OTFT-OLED 어레이 제작)

  • Ryu, Gi-Seong;Kim, Young-Bae;Song, Chung-Kun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.12-18
    • /
    • 2008
  • Ag paste was employed for source and drain electrode of OTFTs and for the data metal lines of OTFT-OLED array on PC(polycarbonate) substrate. We tested two kinds of Ag-pastes such as pastes for 325 mesh and 500 mesh screen mask to examine the pattern ability and electrical performance for OTFTs. The minimum feature size was 60 ${\mu}m$ for 325 mesh screen mask and 40 ${\mu}m$ for 500 mesh screen mask. The conductivity was 60 $m{\Omega}/\square$ for 325 mesh and 133.1 $m{\Omega}/\square$ for 500 mesh. For the OTFT performance the mobility was 0.35 $cm^2/V{\cdot}sec$ and 0.12 $cm^2/V{\cdot}sec$, threshold voltage was -4.7 V and 0.9 V, respectively, and on/off current ratio was ${\sim}10^5$, for both screen masks. We applied the 500 mash Ag paste to OTFT-OLED array because of its good patterning property. The pixel was composed of two OTFTs and one capacitor and one OLED in the area of $2mm{\times}2mm$. The panel successfully worked in active mode operation even though there were a few bad pixels.

Influence of Nanostructured TiO2 Electrode Fabricated with Acid-treated Paste on the Photovoltaic Efficiency of Dye-Sensitized Solar Cells (산처리된 페이스트로 제조한 나노 구조체 TiO2 전극이 염료감응형 태양전지의 효율에 미치는 영향)

  • Lee, Jae-Wook;Hwang, Kyung-Jun;Roh, Sung-Hee;Kim, Sun-Il
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.356-360
    • /
    • 2007
  • Recently, dye sensitized solar cells (DSSCs) composed of nanoporous $TiO_2$, light-sensitive dyes, electrolytes, and counter electrode have been received much attention. Nanostructured particles with higher surface area for the higher adsorption of Ru (II) dye are required to increase the quantity of light absorption. Also, it has been reported that the key factor to achieve high energy conversion efficiency in the photoelectrode of DSSC is the heat treatment of $TiO_2$ paste with acid addition. In this work, we investigated the influence of acid treatment of $TiO_2$ solar cell on the photovoltaic performance of DSSC. The working electrodes fabricated in this work were characterized by X-ray photoelectron spectroscopy (XPS), extended X-ray absorption fine structure (EXAFS), field emission scanning electron microscope (FE-SEM), and atomic force microscope (AFM). In addition, the influence of nanostructured photoelectrode fabricated with the acid-treated paste on the energy conversion efficiency was investigated on the basis of photocurrent-potential curves. It was found that the influence of acid-treated paste on the photovoltaic efficiency was significant.

Piezoelectric Properties of PZW-PMN-PZT Low Loss Multilayer Actuator according to the Number of Multilayer using Pure Ag Internal Electrode (순수한 Ag 내부전극을 사용한 PZW-PMN-PZT 저손실 적층 액츄에이터의 적층수에 따른 압전 특성)

  • Yoo, Ju-Hyun;Lee, Kab-Soo;Lee, Il-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.524-529
    • /
    • 2008
  • In this paper, in order to develop low loss multilayer actuator, piezoelectric properties of PZW-PMN-PZT multilayer actuator sintered at $900^{\circ}C$ low temperature were investigated according to the number of multilayer. The multilayer actuator was fabricated using tape casting method and used pure Ag internal electrode. The density above $8.0\;g/cm^3$ was obtained at all specimens. With increasing number of multilayer, effective electromechanical coupling factor($k_{eff}$) was increased. $k_{eff}$ of multilayer actuator shows the maximum value of 0.283 at 11 layers actuator. However, effective mechanical quality factor(Qm') was decreased according to the increase of number of multilayer. The Qm' of multilayer actuator showed the maximum value of 920 at 5 layers actuator.

AC & DC Electrical Characterization of PTC $BaTiO_3$ and Electrodes (PTC $BaTiO_3$ 및 전극의 직류 및 교류 특성)

  • 전표용;최경만
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 1991
  • 0.2 mo1% La doped BaTiO3 samples were prepared by a wet chemical process (Pechini process) and electrical conductivity were measured from annealing temperatures(800-110$0^{\circ}C$) to room temperature continuously. 2 probe I-V characteristics showed that Pt electrodes were non-ohmic below about 80$0^{\circ}C$ for Ladoped sample. I-V curves showed varistor behavior and breakdown voltages showed PTC-like behavior. AC complex impedance of 0.2 La and 0.05 Mn mo1% doped BaTiO3 samples with three different electrodes (electroless Ni, Pt, Ag electrodes) were measured with temperature variation. Complex impedance plots showed that the samples with electroless Ni electrodes have negligible electrode resistance. Samples with Ag or Pt paste electrodes showed large electrode resistance. PTC effect, which is defined as the ratio of maximum resistance to minimum resistance, was found to be less than 10 for 0.2 mo1% La doped dense sample however greater than 105 with codoping of 0.05 mo1% Mn and 0.2 mol% La.

  • PDF

Surface Reoxidation Mechanism and Electrical Properites of SBLC in $BaTiO_3$ System ($BaTiO_3$계 SBLC의 표면 재산화 형성 기구 및 전기적 성질)

  • 이형규;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.5
    • /
    • pp.55-60
    • /
    • 1986
  • A mechanism for formation of surface reoxidation layer in Surface Boundary Layer Capacitor (SBLC) has been studied. SBLC were prepared by reduction of $BaTiO_3$ doped with $Bi_2O_3$ and electrode firing of silver paste containing $Bi_2O_3$ The apparent dielectric constant was in the order of $10^5$ and the insulation resistance larger than $10^6$$\Omega$ It can be expected that $Bi_2O_3$ dopant in $BaTiO_3$ plays the role of inhibition of grain growth and decreasing the resistivity of $BaTiO_3$. In order to confirm the process of surface reoxidation layer effects of atmosphere and annealing time in electrode sintering were investigated.

  • PDF

Diagnostic Ex-Vivo Assay of glucose Using Diabetic-Control Circuits

  • Ly, Suw Young;Lee, Chang Hyun;Yoo, Hai-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.724-730
    • /
    • 2015
  • For ex-vivo diabetic control, the voltammetric diagnosis of glucose (GU) was conducted with a modified carbon nanotube paste electrode, using handheld analytical circuits. The optimum analytical conditions were attained within the 0.5-4.0 ug/L working range and at the 0.06 ug/L detection limit, which system was interfaced to the feedback circuits and was applied to human urine for diabetic-patient diagnosis. It can be used for ex-vivo flow control analysis, vascular flow detection and other medicinal assays. The equations of the patients' urine are y=36.65x+12.13 and $R^2=0.987$, those of the healthy person of y= 2.5x+10.9 and $R^2=0.928$ (patients: 118 ug/L; healthy person: 12.34 ug/L).

Diagnostic Ex-Vivo Assay of glucose Using Diabetic-Control Circuits

  • Ly, Suw-Young;Kim, Nam-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.210-217
    • /
    • 2014
  • For ex-vivo diabetic control, the voltammetric diagnosis of glucose (GU) was conducted with a modified carbon nanotube paste electrode, using handheld analytical circuits. The optimum analytical conditions were attained within the 0.5-4.0 ug/L working range and at the 0.06 ug/L detection limit, which system was interfaced to the feedback circuits and was applied to human urine for diabetic-patient diagnosis. It can be used for ex-vivo flow control analysis, vascular flow detection, and other medicinal assays.