• Title/Summary/Keyword: Passive work

Search Result 379, Processing Time 0.026 seconds

Bone-like Apatite Morphology on Si-Zn-Mn-hydroxyapatite Coating on Ti-6Al-4V Alloy by Plasma Electrolytic Oxidation

  • Park, Min-Gyu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.158-158
    • /
    • 2017
  • Titanium and its alloys have been used in the field dental and orthopedic implants because of their excellent mechanical properties and biocompatibility. Despite these attractive properties, their passive films were somewhat bioinert in nature so that sufficient adhesion of bone cells to implant surface was delayed after surgical treatment. Recently, plasma electrolyte oxidation (PEO) of titanium metal has attracted a great deal of attention is a comparatively convenient and effective technique and good adhesion to substrates and it enhances wear and corrosion resistances and produces thick, hard, and strong oxide coatings. Silicon(Si), Zinc(Zn), and Manganese(Mn) have a beneficial effect on bone. Si in particular has been found to be essential for normal bone and cartilage growth and development. And, Zn has been shown to be responsible for variations in body weight, bone length and bone biomechanical properties. Also, Mn influences regulation of bone remodeling because its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. The objective of this work was research on bone-like apatite morphology on Si-Zn-Mn-hydroxyapatite coating on Ti-6Al-4V alloy by plasma electrolytic oxidation. Anodized alloys were prepared at 280V voltage in the solution containing Si, Zn, and Mn ions. The surface characteristics of PEO treated Ti-6Al-4V alloy were investigated using XRD, FE-SEM, and EDS.

  • PDF

Changes in the electrochemical properties of air-formed oxide film-covered AZ31 Mg alloy in aqueous solutions containing various anions

  • Fazal, Basit Raza;Moon, Sungmo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.96.2-96.2
    • /
    • 2017
  • This research was conducted to investigate the electrochemical properties of the thin air-formed oxide film-covered AZ31 Mg alloy. In this work, native air-formed oxide films on AZ31 Mg alloy samples were prepared by knife-abrading method and the changes in the electrochemical properties of the air-formed oxide film were investigated in seven different electrolytes containing the following anions $Cl^-$, $F^-$, $SO{_4}^{2-}$, $NO_3{^-}$, $CH_3COO^-$, $CO{_3}^{2-}$ and $PO{_4}^{3-}$. It was observed from open circuit potential (OCP) transients that the potential initially decreased before gradually increasing again in the solutions containing only $CO{_3}^{2-}$ or $PO{_4}^{3-}$ ions, indicating the dissolution or transformation of the native air-formed oxide film into new more protective surface films. The Nyquist plots obtained from electrochemical impedance spectroscopy (EIS) showed that there was growth of new surface films with immersion time on the air-formed oxide film-covered specimens in all the electrolytes; the least resistive surface films were formed in fluoride and sulphate baths whereas the most protective film was formed in phosphate bath. The potentiodynamic polarization curves illustrated that passive behaviour of AZ31 Mg alloy under anodic polarization appears only in $CO{_3}^{2-}$ or $PO{_4}^{3-}$ ions containing solutions and at more than $-0.4V_{Ag/AgCl}$ in $F^-$ ion containing solution.

  • PDF

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

A Case Study on the Effect of the Art Therapy through the Self Expression and the Interpersonal Relations by a Schizophrenic Adolescent I (정신분열증 청년의 자기표현과 상호작용의 효과에 관한 미술치료 사례연구 I)

  • Park, Soo-Jung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.2
    • /
    • pp.229-242
    • /
    • 2009
  • Objectives : This article aims to find how effective the art therapy is on the improvement of the self expression and the interpersonal relations with others, as medium for verbal communication of schizophrenic patients. Methods : The subject of this study was one schizophrenic patient who had been treated with drugs for five years in W university hospital, as well as counseled by an art therapy oo counsel office in J city. The art therapy had been performed the total 25 sessions, fifty minute per session, one session per week, from November 28 in 2008 to April 27 in 2009. The test was by HTP. Results : The results of this study are as follows: First, in the pretest of HTP, the subject showed a little lethargy, painting very simple house-shaped figures and too simple rectangular figures corresponding to those painted by 4 or 5-year-old children. In the post-test, however, the structures of houses were described concretely and three-dimensionally, and the descriptions of people were changed into concrete figure, by which we could see the improvement effect on the self expression and the interpersonal relations. Second, in the earlier stage, there was little verbal self expression, and little self respect, staring into space and showing passive attitude without positive assertion and expression. In the later stage, however, there were positive assertion and expression, even showing sense of humor. Lastly, in the earlier stage, there were few interpersonal relations. In the later stage, however, eye contacts and the interpersonal relations were increased during conversation and in the art work process, respectively. Conclusions : These results suggest that the art therapy can be effective on improvement of the self expression and the interpersonal relations with others, as medium for verbal communication of schizophrenic patients.

  • PDF

A Study on the Impulse Waves Discharged from the Exit of the Convergent and Divergent Pipes (축소관과 확대관 출구로부터 방출되는 펄스파에 관한 연구)

  • Lee, D.H.;Lee, M.H.;Kweon, Y.H.;Kim, H.D.;Park, J.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.5
    • /
    • pp.346-354
    • /
    • 2002
  • The present study is to investigate the propagation characteristics of the impulse waves discharged from the exit of the convergent and divergent pipes. An experiment is carried out using a shock tube with an open end and is compared to the computation of the axisymmetric, compressible, unsteady Euler equations, which are solved by the second-order total variation diminishing (TVD) scheme. For the computational work, several initial compression waves are assumed inside the pipe so that those are the same to the experimental ones of the shock tube. The results show that the peak pressures of the impulse waves discharged from the exit of convergent and divergent pipes decrease with an increase in the wavelength of the initial compression wave. All of the impulse waves have a strong directivity toward the pipe axis, regardless of the exit type of the pipe employed. The impulse waves discharged from the divergent pipe are stronger than those from the straight pipe, while the impulse waves of the convergent pipe are weaker than those from the straight pipe. It is found that the convergent pipe can play a role of a passive control to reduce the peak pressure of the impulse wave. The present computations represent the experimented impulse waves with a good accuracy.

Gamipaidok-san Possesses Antiallergic and Anti-inflammatory Activities

  • Kim Dae-Nam;Kim Ji-Young;Han Eun-Hee;Oh Kyo-Nyeo;Kim Sung-Hoon;Jin Mi-Rim;Jeong Hye-Gwang;Kim Dong-Hee
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1659-1665
    • /
    • 2005
  • Gamipaidok-san(GPDS) is the Hyungbangpaidok-san prescription fortified with the additional ingredients known to be effective for dermatitis. So it has been used for atopic dermatitis in the clinic work actually. In this study, we investigated the effects of GPDS on in vitro and in vivo anti-allergic effect on RBL-2H3 rat basophilic leukemia Cells and on IgE-induced passive cutaneous anaphylaxis (PCA) in mice. The in vitro anti-inflammatory activity of GPDS in RAW 264.7 cells was investigated. GPDS potently inhibited $\beta$-hexosaminidase release from RBL-2H3 and the IgE-mediated PCA reaction in mice. GPDS inhibited LPS-induced NO and PGE2 production in a dose-dependent manner Furthermore, It also inhibited inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2) protein expression in RAW 264.7 cells, and the activation of the transcription factor, NF-kB, in nuclear fraction. The antiallergic action of GPDS may originate from anti-inflammatory activities, and can improve the inflammation caused by allergies.

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • v.37 no.5
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

Emergy-Simulation Based Building Retrofit

  • Hwang, Yi
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.5-13
    • /
    • 2014
  • This paper introduces emergy(spelled with "m") that is a new environmental indicator in architecture, aiming to clarify conflicting claims of building design components in the process of energy-retrofit. Much of design practitioners' attention on low energy use in operational phases, may simply shift the lowered environmental impact within the building boundary to large consumption of energy in another area. Specifically, building energy reduction strategies without a holistic view starting from natural formation, may lead to the depletion of non-renewable geobiological sources (e.g. minerals, fossil fuels, etc.), which leaves a building with an isolated energy-efficient object. Therefore, to overcome the narrow outlook, this research discusses the total ecological impact of a building which embraces all process energy as well as environmental cost represented by emergy. A case study has been conducted to explore emergy-driven design work. In comparison with operational energy-driven scenarios, the results elucidate how energy and emergy-oriented decision-making bring about different design results, and quantify building components' emergy contribution in the end. An average-size ($101.9m^2$) single family house located in South Korea was sampled as a benchmark case, and the analysis of energy and material use was conducted for establishment of the baseline. Adoption of the small building is effective for the goal of study since this research intends to measure environmental impact according to variation of passive design elements (windows size, building orientation, wall materials) with new metric (emergy) regardless of mechanical systems. Performance simulations of operational energy were developed and analyzed separately from the calculation of emergy magnitudes in building construction, and then the total emergy demand of each proposed design was evaluated. Emergy synthesis results verify that the least operational energy scenario requires greater investment in indirect energy in construction, which clearly reveals that efficiency gains are likely to be overwhelmed by increment of material flows. This result places importance on consideration of indirect energy use underscoring necessity of emergy evaluation towards the environment-friendly building in broader sense.

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.

A Study on the Management of Environmental Education in Elementary School -A Case Study of Elementary Schools- (초등학교 환경교육 운영에 대한 연구 -초등학교 실행 사례를 중심으로-)

  • 김용근
    • Hwankyungkyoyuk
    • /
    • v.15 no.2
    • /
    • pp.86-99
    • /
    • 2002
  • The purpose of this study is to make clear the management of Environmental Education in Elementary school in Korea. To accomplish this purpose, The research for the actual condition of management of Environmental Education according to school, grade, and class was progressed. The researcher was analyzed Hindrance Factors of Sound Environmental Education in School and presented some suggestion on the basis of above-mentioned findings. On one side, the method of research is a case study on qualitative based way. A case study was conducted with it's focus on public elementary school in Seoul. As for major research methods, observation by participating in school field and in-depth interview were respectively employed; subsidiary methods included literature study. The findings of this study are as belows: First, Environmental Education was not managed practically with specific way in school. Second, Environmental Education by direct and actual outdoor experience was unusual. Third, most of class school work about Environmental Education was focused on not only the type of prescription after the environmental problem but also, the treatment of articles in newspaper and TV. Forth, educational compulsion such as “you have to do that.” was mainly used as Environmental guidance for sound attitude in school without clear reasons. In the last analysis, hindrance factors of sound management for environmental education in elementary schools were ‘passive adjustment’, ‘discriminative reception’, ‘absence of information resource’. these factors came from atmosphere of negligence environmental education in schools. Therefore, all of teachers have to affirmative belief and attitude as personal dimension and all of elementary schools improve environmental education system.

  • PDF