• 제목/요약/키워드: Passive system

Search Result 2,259, Processing Time 0.03 seconds

Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm (RLSE알고리즘을 이용한 원격 정전용량형 습도 센서 시스템)

  • Kyung-Yup Kim;Joon-Tark Lee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially. by applying the forgetting factor we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.

A Study on the Thermal resistance Performance Evaluation Method of Building Exterior System for Passive House Construction (패시브하우스 구축을 위한 건물외피시스템 단열성능 평가 기법 개발에 관한 연구)

  • Kim, Young-Bong;Moon, Jae-Sik;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.143-144
    • /
    • 2017
  • Due to the recent depletion of natural resources and global warming, a passive house type building exterior system has been developed and applied. For this purpose, we developed a building exterior thermal resistance performance evaluation system and verify the feasibility of this system for evaluation of passive house building system.

  • PDF

Vibration Control of Stay Cable Using Smart Passive Damping System (스마트 수동 감쇠 시스템을 이용한 사장 케이블의 진동 제어)

  • Jung Hyung-Jo;Cho Sang-Won;Jang Ji-Eun;Lee In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.497-504
    • /
    • 2005
  • Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Several methods have been proposed and implemented to mitigate this problem, though each has its limitations. Recently some studies have shown that active and semiactive control system using MR (Magnetorheological) damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart passive damping system using MR dampers by introducing electromagnetic induction (EMI) system as an external power source to MR damper and verified the performance of smart passive damping system for mitigating the vibration of stay cables. The performances of smart passive damping system are compared with those of linear viscous damper and passive-mode MR damper.

  • PDF

A Study on the Monitoring System of Passive Filter to Improve Power Quality (전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

A Study on the Control System of Passive Filter to Reduce Harmonics (고조파 저감을 위한 수동필터의 제어시스템에 관한 연구)

  • 전정채;유재근;이상익
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.124-130
    • /
    • 2004
  • In this paper, we developed DSP(Digital Signal Processor)-based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100HP D.C motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

Design and Application of a Passive Filter Control System

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.152-158
    • /
    • 2004
  • The passive filter is economic and efficient in suppressing harmonics but it may cause resonance problems and its performance is constantly dependent on power system impedance or working conditions of loads. This paper presents the DSP (Digital Signal Processor)-based control system, which automatically controls the passive filter in order to solve these problems. The control system can automatically control the passive filter according to working conditions of loads and measured harmonics, reactive power, power factor and so on. Experimental results in the power system using the 100HP DC motor drive are presented in order to verify the performance of the control system.

Design and Application of Harmonic Passive Filter (고조파 수동필터의 설계 및 적용)

  • Jeon, Jeong-Chay;Kim, Jae-Hyun;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5397-5402
    • /
    • 2012
  • Accidents involving electric equipment and economical loss by power quality deterioration related to harmonics show a rising tendency A passive filter is economic and efficient in suppressing harmonics but many engineers and designers are reluctant to install a passive filter to defect harmonics at their power system because of problems such as harmonic amplification and the probability of generating series or parallel resonance with the power system. This work introduces that passive filters will be very available to defeat harmonic problems of the power system if passive filters are well designed. We describe method and process of harmonic passive filter design. And the passive filter for the power system having harmonic problems due to use of nonlinear loads like as 100HP DC motor system, an extruding machine, an air blower and other loads are designed. Experimental results verify the performance of the passive filter designed by the described method and procedure.

A Study on Target Tracking Filter Architecture in Underwater Environment using Active and Passive Sensors (능, 수동센서를 이용한 수중환경에서의 표적추적필터 구조 연구)

  • Lim, Youngtaek;Suh, Taeil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.517-524
    • /
    • 2015
  • In this paper, we propose a new target tracking filter architecture using active and passive sensors in underwater environment. A passive sensor for target tracking needs a bearing measurement of target. And target tracking filter for using passive sensor has the observability problem. On the other hand, an active sensor does not have the problem associated with system observability problem because an active sensor uses bearing and range measurement. In this paper, the tracking filter algorithm that could be used in the active and passive sensor system is proposed to analyze maneuvering target and to improve target tracking performance. The proposed tracking filter algorithm is tested by a series of computer simulation runs and the results are analyzed and compared with existing algorithm.

Design of SR Drive Using Passive Converter for Hydraulic Pump System (패시브 컨버터를 적용한 유압유니트용 SRM 제어기 설계)

  • Seok, Seung-Hun;Liang, Jianing;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.863_864
    • /
    • 2009
  • Design and drive characteristics of SR drive for hydraulic pump system using passive converter is presented in this paper. In oder to get the high performance, a simple passive circuit is added in the front-end of a conventional asymmetric converter, which consists of three diodes and one capacitor. This passive converter has the high demagnetization voltage, to reduce the demagnetization time. Futhermore optimal turn-off angle for the proposed passive converter is proposed. According to motor speed and current, an optimal turn-off angle can be achieved by look-up table to reduce torque ripple. The characteristic of proposed hydraulic pump system using passive converter is verified by simulation and experimental results.

  • PDF

Path following of the passive off-hooked trailer system (Off-hooked 트레일러 시스템의 궤적 추종)

  • Lee, Jae-Hyoung;Park, Myoung-Kuk;Chung, Woo-Jin;Kim, Mun-Sang;Song, Jae-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1831-1839
    • /
    • 2003
  • This paper deals with design and control of passive multiple trailer systems fer practical applications. Due to cost and complexity of trailer mechanism, passive systems are preferred to active systems in this research. The control objective is to minimize trajectory tracking errors of passive multiple trailers. Three types of passive trailer systems-direct-hooked, three-point, and off-hooked- are discussed in this paper. Trajectory tracking performance and stability issues under constant velocity motion are carried out for three types. Various simulations and experiments have been also performed for these three types. It is shown that the proposed off-hooked trailer system produces better tracking performance than the other types.