• Title/Summary/Keyword: Passive imaging

Search Result 80, Processing Time 0.024 seconds

Image Registration and Fusion between Passive Millimeter Wave Images and Visual Images (수동형 멀리미터파 영상과 가시 영상과의 정합 및 융합에 관한 연구)

  • Lee, Hyoung;Lee, Dong-Su;Yeom, Seok-Won;Son, Jung-Young;Guschin, Vladmir P.;Kim, Shin-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.349-354
    • /
    • 2011
  • Passive millimeter wave imaging has the capability of detecting concealed objects under clothing. Also, passive millimeter imaging can obtain interpretable images under low visibility conditions like rain, fog, smoke, and dust. However, the image quality is often degraded due to low spatial resolution, low signal level, and low temperature resolution. This paper addresses image registration and fusion between passive millimeter images and visual images. The goal of this study is to combine and visualize two different types of information together: human subject's identity and concealed objects. The image registration process is composed of body boundary detection and an affine transform maximizing cross-correlation coefficients of two edge images. The image fusion process comprises three stages: discrete wavelet transform for image decomposition, a fusion rule for merging the coefficients, and the inverse transform for image synthesis. In the experiments, various types of metallic and non-metallic objects such as a knife, gel or liquid type beauty aids and a phone are detected by passive millimeter wave imaging. The registration and fusion process can visualize the meaningful information from two different types of sensors.

Study Of Millimeter-Wave Passive Imaging Sensor Using the Horn Array Antenna (반사판을 이용한 밀리미터파 수동 이미징 시스템 연구)

  • Lim, Hyun-Jun;Chae, Yeon-Sik;Jung, Kyung-Kwon;Kim, Mi-Ra;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • We have developed a millimeter-wave passive imaging system with reflector for detection of concealed objects. We have designed a millimeter-wave sensor, control device for reflector control, and a lens for focusing of millimeter-wave signal at center frequency of 94GHz. DC signal from millimeter-wave sensor output is filtered by low pass filter and amplified by video amplifier, and then converted into digital signal by using ADC/DAQ. This signal is image processed by computer, and it is possible to obtain millimeter-wave passive image with resolution of $18{\times}64$ pixel using the fabricated system. It is shown that we can obtain the image of men and concealed object with the system.

Studies on the millimeter-wave Passive Imaging System (밀리미터파 수동 이미징 시스템 연구)

  • Jung Min-Kyoo;Chae Yeon-Sik;Kim Soon-Koo;Koji Mizuno;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.182-188
    • /
    • 2006
  • In this study, we have designed the millimeter-wave passive imaging system which records energy that is reflected or emitted from the source and produces image. The lens and front-end of receiver appeared to be important in the system to detect input thermal noise signal. The lens for signal focusing has been designed by optical transfer function. Amplifier of the imaging systemhas been set up with 40dB in maximum gain, 5 dB in maximum noise figure, and 10GHz in bandwidth to enhance sensitivity for thermal noise and to receive it in wide-band width as well. The SBD MSS-20 141B10D diode has been used for the detector circuit to convert amplified millimeter-wave signals to DC output.

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

EXPERIMENTAL DEMONSTRATION OF ADVANTAGE OF MOTION INDUCED SYNTHETIC APERTURE RADIOMETER

  • Park, Hyuk;Kim, Sung-Hyun;Lee, Ho-Jin;Moon, Nam-Won;Yu, Hwan-Wook;NamGoong, Up;Sim, Won-Seon;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.22-25
    • /
    • 2008
  • Aperture synthesis with platform motion has been presented as a useful tool to achieve the high spatial resolution imaging. Using a motion induced synthetic aperture radiometer (MISAR), a passive microwave image can be achieved with a small number of antennas. Moreover, the MISAR is capable of imaging better than the case without motion, using the same configuration of antenna array. With a platform motion, visibility can be sampled more efficiently, and as a result the imaging performance of the MISAR shows higher quality than the case without platform motion. In this paper, the advantage of MISAR is demonstrated experimentally. Using a laboratory model of inteferometric radiometer, the point source images are obtained under the condition with platform motion and without platform motion. In the experimental results, the point source response of the MISAR shows better quality of sidelobe level and beam efficiency than the case without platform motion.

  • PDF

Study Of Millimeter-Wave Passive Imaging Sensor Using the Horn Array Antenna (혼 배열 안테나를 이용한 밀리미터파 수동 이미징 센서 연구)

  • Lim, Hyun-Jun;Chae, Yeon-Sik;Kim, Mi-Ra;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.74-79
    • /
    • 2010
  • We have designed a millimeter-wave passive imaging sensor with multi-horn antenna array. Six horn array antenna is suggested that it is integrated into one housing, and this antenna is effectively configurated m space to assemble with LNA of WR-10 structure. Antenna is designed to have the peak gain of 17.5dBi at the center frequency of 94GHz, and the return loss of less than -25dB in W-band, and the small aperture size of $6mm{\times}9mm$ for antenna configuration with high resolution. LNA is designed to have total gain of more than 55dB and noise figure of less than 5dB for good sensitivity. We made a detector for DC output translation of millimeter-wave signal with zero bias Schottky diode. It is shown that good sensitivity of more than 500mV/mW.

Extraction of Distance Information with Nonlinear Correlation of Photon-Counting Integral Imaging

  • Yeom, Seokwon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.579-585
    • /
    • 2016
  • Integral imaging combined with photon-counting detection has been researched for three-dimensional information sensing under low-light-level conditions. This paper addresses the extraction of distance information with photon-counting integral imaging. The longitudinal distance to the object is obtained utilizing photon-counting elemental images. The pixel disparity is estimated by maximizing the nonlinear correlation of photocounts. The first- and second-order statistical properties of the nonlinear correlation are theoretically derived. In the experiments, these properties are verified by varying the mean number of photocounts in the scene. The average distance is compared to that from the intensity information, showing the robustness of the proposed system even at low photocounts.

The Effect of Different Starting Periods of Passive Exercise on the Clinical Outcome of Arthroscopic Rotator Cuff Repair

  • Back, Young-Woong;Tae, Suk-Kee;Kim, Min-Kyu;Kwon, Oh-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.57-63
    • /
    • 2014
  • Background: To compare the effect of different starting periods of rehabilitative exercise (early or delayed passive exercise) on the rate of retear and other clinical outcomes after the arthroscopic repair of the rotator cuff. Methods: In total, 103 patients who underwent arthroscopic repair of the rotator cuff were included in the study. Determined at 2 weeks post-operation, patients who were incapable of passive forward elevation greater than $90^{\circ}$ were allotted to the early exercise group (group I: 79 patients; 42 males, 37 females), whilst those capable were allotted to the delayed exercise group (group II: 24 patients; 14 males, 10 females). The group I started passive exercise, i.e. stretching, within 2 weeks of operation, whilst group II started within 6 weeks. The results were compared on average 15.8 months (11-49 months) post-operation using the passive range of motion, the Visual Analog Scale (VAS) pain score, and the University of California at Los Angeles (UCLA) and Constant scores. Stiffness was defined as passive forward elevation or external rotation of less than $30^{\circ}C$ compared to the contralateral side. Follow-up magnetic resonance imaging (MRI) was carried out on average 1 year post-operation and the rate of retear was compared with Sugaya's criteria. Results: There were no differences between the two groups in gender, age, smoking, presence of diabetes, arm dominance, period of tear unattended, pre-operative range of motion, shape and size of tear, degree of tendon retraction, and tendon quality. There were no significant differences in clinical outcomes. Whilst stiffness was more frequent in group II (p-value 0.03), retear was more frequent in group I (p-value 0.028) according to the MRI follow-up. Conclusions: During rehabilitation after the arthroscopic repair of the rotator cuff, the delay of passive exercise seems to decrease the rate of retear but increase the risk of stiffness.

A Study on the Target Tracking Algorithm based on the Target Size Estimation (표적 크기 추정 기반의 표적 추적 알고리듬 연구)

  • Jung, Yun Sik;Lee, Sang Suk;Rho, Shin Baek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • In this paper, a novel MBE (Model Based target size Estimator) is presented for SDIIR (Strap Down Imaging Infrared) seekers. The target tracking requires the target size information for which residual range between target and missile should be provided. Unfortunately, in general, the missile with passive sensor such as IIR (Imaging Infrared), CCD (Coupled Charging Device) cannot obtain range information. To overcome the problem, the proposed method enables the SDIIR seeker to estimates target size by using target size model and track the target. The performance of proposed method is tested at IIR target tracking of target intercept scenario. The experiment results show that the proposed algorithm has the relatively good performance.