• 제목/요약/키워드: Passive heating

검색결과 133건 처리시간 0.027초

오스테나이트계 스테인리스강에 대한 질소 고용화 처리 및 그 효과 (Solution Nitriding and Its Effect on the Austenitic Stainless Steels)

  • 허정;남태운
    • 열처리공학회지
    • /
    • 제13권5호
    • /
    • pp.337-345
    • /
    • 2000
  • As a case hardening process for stainless steels, nitriding is more preferred and widely used than carburizing which deterioates corrosion resistance severely. In order to add the nitrogen into the stainless steels, passive film on the surface must be removed effectively before nitriding. Conventional gas nitriding process is performed in the temperature range of 500 to $600^{\circ}C$ with $NH_3$ gas, which often leads to sensitization of stainless steels. In this study, we tried to activate passive film of austenitic stainless steels by heating at low pressure. ($900^{\circ}C$, $5{\times}10^{-2}$ Torr.) Nitriding was performed at the solution treatment temperature of $1100^{\circ}C$ with nitrogen molecules instead of $NH_3$ gas. An attainable nitrogen content in a case depends on the nitrogen gas pressure at constant nitriding temperature. A case depth is proportional to the square root of solution time, which suggests that inward diffusion of nitrogen follows the Fick's 2nd law. Surface nitrogen atoms are dissolved as interstitial solutes, or precipitated in the form of MN, $M_2N$ nitrides, which increase the case hardeness. Dissolved nitrogen in the case enhances the cavitation resistance of austenitic stainless steels dramatically.

  • PDF

AN EVALUATION OF THE APERIODIC AND FLUCTUATING INSTABILITIES FOR THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN INTEGRAL REACTOR

  • Kang Han-Ok;Lee Yong-Ho;Yoon Ju-Hyeon
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.343-352
    • /
    • 2006
  • Convenient analytical tools for evaluation of the aperiodic and the fluctuating instabilities of the passive residual heat removal system (PRHRS) of an integral reactor are developed and results are discussed from the viewpoint of the system design. First, a static model for the aperiodic instability using the system hydraulic loss relation and the downcomer feedwater heating equations is developed. The calculated hydraulic relation between the pressure drop and the feedwater flow rate shows that several static states can exist with various numbers of water-mode feedwater module pipes. It is shown that the most probable state can exist by basic physical reasoning, that there is no flow rate through the steam-mode feedwater module pipes. Second, a dynamic model for the fluctuating instability due to steam generation retardation in the steam generator and the dynamic interaction of two compressible volumes, that is, the steam volume of the main steam pipe lines and the gas volume of the compensating tank is formulated and the D-decomposition method is applied after linearization of the governing equations. The results show that the PRHRS becomes stabilized with a smaller volume compensating tank, a larger volume steam space and higher hydraulic resistance of the path $a_{ct}$. Increasing the operating steam pressure has a stabilizing effect. The analytical model and the results obtained from this study will be utilized for PRHRS performance improvement.

국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구 (Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses)

  • 이충국;이정철;김상수;서승직
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

제로에너지타운 내 주택 에너지 성능 평가에 관한 연구 (A Study on the Energy Performance Evaluation of Zero Energy House in Zero Energy Town)

  • 이왕제;백남춘;이경호;허재혁
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.85-91
    • /
    • 2015
  • In this study, energy performance analysis of houses in zero energy demonstration town(ZeT) was carried out using the monitoring results. This ZeT was composed 29 zero energy individual houses(ZeH) which were applied passive as well as active technologies. The results are as follows. (1) Residents are generally considered to have been lacking basic mind to save energy, (2) In particular, average yearly total energy consumption per house is 12,834 kWh and specific heating energy is $53.2kWh/m^2{\cdot}yr$ which is higher than that of passive house. This is because of one of the reason just pointed out in subsection (1). (3) Most part of the residual energy load are supplied with only renewable energy, but not operating energy for geothermal heat pump which is use of cheap electricity.

Abnormal Winter Melting of the Arctic Sea Ice Cap Observed by the Spaceborne Passive Microwave Sensors

  • Lee, Seongsuk;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권4호
    • /
    • pp.305-311
    • /
    • 2016
  • The spatial size and variation of Arctic sea ice play an important role in Earth's climate system. These are affected by conditions in the polar atmosphere and Arctic sea temperatures. The Arctic sea ice concentration is calculated from brightness temperature data derived from the Defense Meteorological Satellite program (DMSP) F13 Special Sensor Microwave/Imagers (SSMI) and the DMSP F17 Special Sensor Microwave Imager/Sounder (SSMIS) sensors. Many previous studies point to significant reductions in sea ice and their causes. We investigated the variability of Arctic sea ice using the daily sea ice concentration data from passive microwave observations to identify the sea ice melting regions near the Arctic polar ice cap. We discovered the abnormal melting of the Arctic sea ice near the North Pole during the summer and the winter. This phenomenon is hard to explain only surface air temperature or solar heating as suggested by recent studies. We propose a hypothesis explaining this phenomenon. The heat from the deep sea in Arctic Ocean ridges and/or the hydrothermal vents might be contributing to the melting of Arctic sea ice. This hypothesis could be verified by the observation of warm water column structure below the melting or thinning arctic sea ice through the project such as Coriolis dataset for reanalysis (CORA).

SMA-based devices: insight across recent proposals toward civil engineering applications

  • Casciati, Sara
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.111-125
    • /
    • 2019
  • Metallic shape memory alloys present fascinating physical properties such as their super-elastic behavior in austenite phase, which can be exploited for providing a structure with both a self-centering capability and an increased ductility. More or less accurate numerical models have been introduced to model their behavior along the last 25 years. This is the reason for which the literature is rich of suggestions/proposals on how to implement this material in devices for passive and semi-active control. Nevertheless, the thermo-mechanical coupling characterizing the first-order martensite phase transformation process results in several macroscopic features affecting the alloy performance. In particular, the effects of day-night and winter-summer temperature excursions require special attention. This aspect might imply that the deployment of some devices should be restricted to indoor solutions. A further aspect is the dependence of the behavior from the geometry one adopts. Two fundamental lacks of symmetry should also be carefully considered when implementing a SMA-based application: the behavior in tension is different from that in compression, and the heating is easy and fast whereas the cooling is not. This manuscript focuses on the passive devices recently proposed in the literature for civil engineering applications. Based on the challenges above identified, their actual feasibility is investigated in detail and their long term performance is discussed with reference to their fatigue life. A few available semi-active solutions are also considered.

LTCC 기판의 일 방향 소결 (Unidirectional Sintering in LTCC Substrate)

  • 선용빈;안주환;김석범
    • 마이크로전자및패키징학회지
    • /
    • 제11권4호
    • /
    • pp.37-41
    • /
    • 2004
  • 이동 통신 기기의 광대역화에 따라 기존의 인쇄 회로 기판에 비해 양호한 전기적 특성과 수동형 부품을 내장할 수 있는 LTCC(Low Temperature Co-fired Ceramic)에 대한 많은 연구 개발이 진행되고 있으나 불 균일한 수축으로 인해 적용에 한계를 보여 왔다. 본 연구에서는 짧은 시간내에 온도를 균일하게 올릴 수 있는 혼합 가열 방식을 개발하여 하부에서부터 시편의 얇은 층이 순차적으로 소결 되도록 하는 일 방향 소결의 조건을 제공하여 시편 상부 표면의 배선 형상이 종래의 전기로 가열보다 안정적으로 형성되는 결과를 얻었다. 기판의 소결 특성, 배선의 전기적 특성, 그리고 배선의 기계적 특성 등을 비교한 결과, 기판의 소형화와 배선의 고밀도화에 전기로 가열 보다 혼합 가열이 적용 가능성이 높음을 알 수 있었다.

  • PDF

가열처리에 따른 우유와 달걀의 Allegenicity의 변화와 소화율에 관한 연구 (Changes in Allergenicity and Digestibility of Egg and Milk by Heat Treatment)

    • 동아시아식생활학회지
    • /
    • 제11권2호
    • /
    • pp.104-111
    • /
    • 2001
  • The first purpose of this study was to determine the changes in the allergenicity of milk and egg with heat treatment. The allergenicity of milk and egg is known to have a strong antigen. The second purpose of this study was to observe changes of disestibility of milk and egg after heat treatment. For this study, passive cutaneous anaphylaxis(PCA) inhibition experiment by using guinea pig and nonprotein nitrogen(NPN)experiment were attempted. The result were following: 1. The allergenicity of both milk and egg was reduced by heat treatment. 2. The degree of hydrolysis and PCA inhibition increased with longer heating time. 3. The increse in both the degree of hydrolysis and PCA inhibition of milk was higher than that of egg. 4. Egg contained a greater amount of allergen than milk after heat treatment. 5. The digestibility of both milk and egg was reduced by heat treatment. 6. The digestibility was reduced further by increasing heating time. 7. The digestibility of egg was lower than that of milk after the treatment.

  • PDF

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

재실 감지 센서를 이용한 다용도 스마트 센서 개발 (Development of Multi-purpose Smart Sensor Using Presence Sensor)

  • 차주헌;용흥
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.103-109
    • /
    • 2015
  • This paper introduces a multi-purpose smart fusion sensor. Normally, this type of sensor can contribute to energy savings specifically related to lighting and heating/air conditioning systems by detecting individuals in an office building. If a fire occurs, the sensor can provide information regarding the presence and location of residents in the building to a management center. The system consists of four sensors: a thermopile sensor for detecting heat energy, an ultrasonic sensor for measuring the distance of objects from the sensor, a fire detection sensor, and a passive infrared sensor for detecting temperature change. The system has a wireless communication module to provide the management center with control information for lighting and heating/air conditioning systems. We have also demonstrated the usefulness of the proposed system by applying it to a real environment.