• 제목/요약/키워드: Passive filter

검색결과 359건 처리시간 0.025초

형광물질을 이용한 대기 중 오존 Passive Sampler의 개발 (Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone)

  • 임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

오차의 허용범위를 고려한 수동형 필터의 특성 해석 (Performance Analysis for Passive Filter Considering Allowable Limits of Tolerance)

  • 김종겸;김일증
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.38-43
    • /
    • 2009
  • Reactors are connected with capacitors to passive filter circuits for reducing harmonics caused by power conversion application. This passive filter frequently gets out of order by voltage and current stress. Especially filter reactor has too much voltage harmonics components, its trouble rate is higher than capacitor. In this paper, we analyzed voltage and current of reactor and capacitor used for passive filter by simulation and measurement. If reactor has a tolerance on variation of reactance value, series resonance frequency is different from originally filter design frequency and parallel resonance can be generated at the close point of the former. Because filter absorbs harmonic component of non-linear load, much of harmonic voltage has been impacted on reactor.

개선된 Chebyshev 함수와 DDA를 이용한 연속시간 필터 설계 (Design of a Continuous-Time Filter Using the Modified Chebyshev Function and DDA)

  • 최석우;윤창훈;김동용
    • 전자공학회논문지B
    • /
    • 제32B권12호
    • /
    • pp.1572-1580
    • /
    • 1995
  • In this paper, a modified Chebyshev low-pass filter function is proposed. The modified Chebyshev filter function exhibits ripples diminishing toward .omega. = 0 in the passband. So, the modified filter function is realizable in the passive doubly-terminated ladder network for the order n even or odd, thus lending itself amenable to active RC or switched capacitor filters through the simulation techniques. Besides the passive doubly-terminated ladder realizability, lower pole-Q values of the modified function are accountable for improved phase and delay characteristics, as compared to classical function. We have designed the 6th order passive doubly-terminated network using the modified function. And then a continuous-time DDA(Differential Difference Amplifier) filter, which has no matching requirement, is realized by leap-frog simulation technique for fabrication. In the HSPICE simulation results, we confirmed that the designed continuous-time DDA filter characteristics are agreement with the passive filter.

  • PDF

An Active Output Filter with a Novel Control Strategy for Passive Output Filter Reduction

  • Choi, Kyusik;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1036-1045
    • /
    • 2016
  • This paper presents a novel control strategy for passive output filter reduction using an active output filter. The proposed method achieves the dual-function of regulating the output voltage ripple and output voltage variation during load transients. The novel control strategy allows traditional simple voltage controllers to be used, without requiring the expensive current sensors and complex controllers used in conventional approaches. The proposed method is verified with results from a 125-W forward converter.

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.

Design and Application of a Passive Filter Control System

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.152-158
    • /
    • 2004
  • The passive filter is economic and efficient in suppressing harmonics but it may cause resonance problems and its performance is constantly dependent on power system impedance or working conditions of loads. This paper presents the DSP (Digital Signal Processor)-based control system, which automatically controls the passive filter in order to solve these problems. The control system can automatically control the passive filter according to working conditions of loads and measured harmonics, reactive power, power factor and so on. Experimental results in the power system using the 100HP DC motor drive are presented in order to verify the performance of the control system.

A Study on the Design and Characteristics of thin-film L-C Band Pass Filter

  • Kim In-Sung;Song Jae-Sung;Min Bok-Ki;Lee Won-Jae;Muller Alexandru
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.176-179
    • /
    • 2005
  • The increasing demand for high density packaging technologies and the evolution to mixed digital and analogue devices has been the con-set of increasing research in thin film multi-layer technologies such as the passive components integration technology. In this paper, Cu and TaO thin film with RF sputtering was deposited for spiral inductor and MOM capacitor on the $SiO_2$/Si(100) substrate. MOM capacitor and spiral inductor were fabricated for L-C band pass filter by sputtering and lift-off. We are analyzed and designed thin films L-C passive components for band pass filter at 900 MHz and 1.8 GHz, important devices for mobile communication system. Based on the high-Q values of passive components, MOM capacitor and spiral inductors for L-C band pass filter, a low insertion loss of L-C passive components can be realized with a minimized chip area. The insertion loss was 3 dB for a 1.8 GHz filter, and 5 dB for a 900 MHz filter. This paper also discusses a analysis and practical design to thin-film L-C band pass filter.

릴레이 구동회로 및 수동필터를 이용한 단상 전원의 부하 적응형 고조파 전류 제거 기법 (The Method for Harmonics Elimination of a Single Phase Current by the Analog Relay Control Circuit and Passive Filters)

  • 박종연;이후찬;이봉진;최원호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권6호
    • /
    • pp.292-298
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to eliminate harmonic currents of nonlinear load and can also improve the power factor. They are not often optimal filters because the passive filters are designed under the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. We presents the new control method of passive filter selection type with the relay control circuit which is consist of analog GIC, comparater, flip-flop and etc. By the experimental results using the proposed system for the rectifier load, we concluded that the researched method is cost effective and the performance is better than the passive filter.

수동형 필터의 리액터 및 커패시터 특성 해석 (Characteristics Analysis of Reactor and Capacitor for Passive Filter)

  • 김일중;김종겸
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.82-88
    • /
    • 2009
  • 전력용 커패시터는 유도성 부하의 낮은 역률을 보상하기 위해 설치하는 경우가 많지만, 전력변환장치에서 발생하는 고조파를 줄이기 위해 수동형 필터로서 리액터와 함께 사용되는 경우도 있다. 수동형 필터는 커패시터와 리액터를 직렬로 연결하여 사용한다. 필터는 비선형 부하에서 발생하는 고조파를 흡수하는 역할을 하기 때문에 전압 및 전류 스트레스를 받아 소손 또는 열화되어 정상적인 수명을 보장받지 못하는 경우가 많다. 본 논문에서는 PWM 인버터의 전원측에 설치된 수동형 필터가 고조파를 저감할 때 받는 영향을 해석하였다.

고 전력 RF-Filter의 수동혼변조 저감방안에 대한 연구 (Study on Passive Intermodulation Reduction for High Power RF-Filter)

  • 박종철;이강훈;이영철
    • 한국전자통신학회논문지
    • /
    • 제3권4호
    • /
    • pp.282-288
    • /
    • 2008
  • 본 연구에서는 고출력 RF 필터의 도금상태에 따른 수동혼변조왜곡(PIMD)을 측정하였으며 RF-filter의 PIMD를 저감시키기 위한 방안을 제시하였다. PIMD의 표준측정방안에 따라 Wibro 중계기용 고출력 RF-필터의 PIMD 특성를 측정하였다. Wibro용 고 전력-RF 필터의 설계에서 통과대역의 에지(edge)에서 삽입손실 및 지연 특성의 평탄도가 저하될 경우, PIMD의 발생되므로 본 연구에서는 고 전력 필터의 PIM을 감소시키기 위하여 필터의 내부 도금 재료의 종류와 방안을 제시하였다.

  • PDF