• Title/Summary/Keyword: Passive design method

Search Result 373, Processing Time 0.025 seconds

Mitigation of Transmission Line Magnetic Field by Installation of Passive Shield-Loop. (수동루프 설치에 의한 송전선로 자계 저감)

  • Kim Jeong-Boo;Shin Koo-Yong;Shin Myung Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.2
    • /
    • pp.59-61
    • /
    • 2006
  • In our country most of transmission lines are double-circuit lines. In these lines, the combining method of increasing conductor height and installation of passive shield-loop to mitigate magnetic field near a transmission line, is a good and feasible method. The basic principle of passive shield loop is that the field from the current induced in the shield loop conductors counteracts the field from the phase conductors. This method applied to domestic transmission lines to meet the magnetic field level, 100, 30, 10 and 4 mG, respectively. In each magnetic field level, the minimum conductor height and passive loop height are presented for the implementation of the practical design.

Design Method Development of Smart TMD for Retractable-Roof Spatial Structure (개폐식 대공간 구조물을 위한 스마트 TMD 설계기법 개발)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.3
    • /
    • pp.107-115
    • /
    • 2017
  • In this paper, a structural design method of a smart tuned mass damper (TMD) for a retractable-roof spatial structure under earthquake excitation was proposed. For this purpose, a retractable-roof spatial structure was simplified to a single degree of freedom (SDOF) model. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. This condition was considered in the numerical simulation. A magnetorheological (MR) damper was used to compose a smart TMD and a displacement based ground-hook control algorithm was used to control the smart TMD. The control effectiveness of a smart TMD under harmonic and earthquake excitation were evaluated in comparison with a conventional passive TMD. The vibration control robustness of a smart TMD and a passive TMD were compared along with the variation of natural period of a simplified structure. Dynamic responses of a smart TMD and passive TMD under resonant harmonic excitation and earthquake load were compared by varying mass ratio of TMD to total mass of the simplified structure. The design procedure proposed in this study is expected to be used for preliminary design of a smart TMD for a retractable-roof spatial structure.

Strain Characteristics of Reinforcing materials in the transition zone of slopes (사면의 변이영역에서 보강재의 변형률 특성)

  • 김경태;장대수;장기태;한희수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

Wheeled Blimp: Hybrid Structured Airship with Passive Wheel Mechanism for Tele-guidance Applications

  • Kang, Sung-Chul;Nam, Mi-Hee;Kim, Bong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1941-1948
    • /
    • 2004
  • This paper presents a novel design of indoor airship having a passive wheeled mechanism and its stationary position control. This wheeled blimp can work both on the ground using wheeled vehicle part and in the air using the floating capability of the blimp part. The wheeled blimp stands on the floor keeping its balance using a caster-like passive wheel mechanism. In tele-guidance application, stationary position control is required to make the wheeled blimp naturally communicate with people in standing phase since the stationary blimp system responds sensitively to air flow even in indoor environments. To control the desired stationary position, a computed torque control method is adopted. By performing a controller design through dynamic analysis, the control characteristics of the wheeled blimp system have been found and finally the stable control system has been successfully developed. The effectiveness of the controller is verified by experiment for the real wheeled blimp system.

Strain Distribution of transition zone in a nailed wall (네일로 보강된 구조물에서의 변이영역과 변형률 분포)

  • 장기태;남궁한;유병선;김경태;권병근;이선경
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.235-239
    • /
    • 2000
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

Strain Distribution of Transition Zone in a Nail Wall (네일로 보강된 구조물에서의 변이영역과 변형률 분포)

  • Chang, Ki-Tae;NamGung, Han;Yoo, Byung-Sun
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2005
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain istribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

Application of Experimental Design Methods for Minimum Weight Design and Sensitivity Evaluation of Passive-Type Deck Support Frame for Offshore Plant Float-Over Installation (해양플랜트 플로트오버 설치 공법용 수동형 갑판 지지 프레임의 최소중량설계와 민감도 평가를 위한 실험계획법 응용)

  • Kim, Hun Gwan;Lee, Kangsu;Song, Chang Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.161-171
    • /
    • 2021
  • This paper presents the findings of a comparative study on minimum weight design and sensitivity evaluation using different experimental design methods for the structural design of an active-type deck support frame (DSF) developed for the float-over installation of an of shore plant topside. The thickness sizing variables of the structural members of a passive-type DSF were considered the design factors, and the output responses were defined using the weight and strength performances. The design of the experimental methods applied in the comparative study of the minimum weight design and the sensitivity evaluation were the orthogonal array design, Box- Behnken design, and Latin hypercube design. A response surface method was generated for each design of the experiment to evaluate the approximation performance of the design space exploration according to the experimental design, and the accuracy characteristics of the approximation were reviewed. Regarding the minimum weight design, the design results, such as numerical costs and weight minimization, of the experimental design for the best design case, were evaluated. The Box- Behnken design method showed the optimum design results for the structural design of the passive-type DSF.

A Study of Sustainable Architectural Design Elements Based on the Classification of Natural Elements (자연요소 중심으로 분류한 친환경 건축계획 요소에 관한 연구)

  • Yim, Su Hyun;Park, Hyeon Soo
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.3-12
    • /
    • 2010
  • Sustainable design is getting to be controversial issue in all industries over the world particularly, in architecture as the amount of energy usage in architecture occupies 40%. Therefore, it is essential to make the standard for the sustainable design. In order to construct the sustainable design, firstly it should be considered that sustainable design elements based on natural resources to increase building energy efficiency is established and classified. The method of sustainable design divides into passive design and active design. Passive design method should be examined with active one simultaneously for more efficient usage of energy. Next, the study is followed how the sustainable design elements is adopted in buildings through the comparison of cases study of domestic and oversea. The result of case study shows similar adoption of sustainable design elements between oversea and domestic. However, the difference is shown in the building orientation and shape and the window size and position in Solar energy as well as high performance structure in Heat energy. These elements are the most significant elements in order to reduce energy load. In oversea, sustainable design is generated by architects, a client, and consultants based on the close cooperation in the beginning of early design phase before deciding building shape and envelope while in the domestic field adoption for sustainable design is conducted after deciding building shape and material. In order to design sustainable architecture more study is necessary in early stage for Zero Carbon and reducing building energy load through relation with specialists, a client and architects.

Spring Modeling for the Passive Earth Pressure Acting on the Integral Abutment Bridge (일체식교대 교량에 작용하는 수동토압의 스프링 모델링)

  • 정재호;홍정희;유성근;윤순종
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.420-427
    • /
    • 2002
  • In this paper, a simplified structural spring model of integral abutment bridge is proposed to account for the passive earth pressure due to the change of temperature. The magnitude of earth pressure acting on integral bridge abutment mainly depends on the amount and shape of displacement of abutment according to the thermal expansion of superstructure. The proposed simplified model is developed based on the possible displacement shape of integral abutment bridge. Performing the direct stiffness method, the analysis is done by using the proposed method and the results of new model is compared with those of conventional design approach. The study show that it may be possible to obtain more rational and economical design values for integral abutment bridge by applying the proposed design method.

  • PDF

Application of Chernoff bound to passive system reliability evaluation for probabilistic safety assessment of nuclear power plants

  • So, Eunseo;Kim, Man Cheol
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2915-2923
    • /
    • 2022
  • There is an increasing interest in passive safety systems to minimize the need for operator intervention or external power sources in nuclear power plants. Because a passive system has a weak driving force, there is greater uncertainty in the performance compared with an active system. In previous studies, several methods have been suggested to evaluate passive system reliability, and many of them estimated the failure probability using thermal-hydraulic analyses and the Monte Carlo method. However, if the functional failure of a passive system is rare, it is difficult to estimate the failure probability using conventional methods owing to their high computational time. In this paper, a procedure for the application of the Chernoff bound to the evaluation of passive system reliability is proposed. A feasibility study of the procedure was conducted on a passive decay heat removal system of a micro modular reactor in its conceptual design phase, and it was demonstrated that the passive system reliability can be evaluated without performing a large number of thermal-hydraulic analyses or Monte Carlo simulations when the system has a small failure probability. Accordingly, the advantages and constraints of applying the Chernoff bound for passive system reliability evaluation are discussed in this paper.