• Title/Summary/Keyword: Passive cooling

Search Result 178, Processing Time 0.021 seconds

Derivation of a Simplified Heat Transfer Correlation for AP 600 Passive Containment Cooling System

  • Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.122-130
    • /
    • 1998
  • A simplified heat transfer model for the cooling capability of the AP 600 PCCS is proposed I this paper. As the PCCS domain is covered with very thin and long water film, it is phenomenologically divided into 3 regions; water entrance effect region, asymptotic region, and air entrance effect region. As the length of the asymptotic region is estimated to be over 90% of the whole domain, the phenomena in the asymptotic region is focused. Using the analogy between heat and mass transfer phenomena in a turbulent situation, a new dependent variable combining temperature and vapor mass fraction was defined. The similarity between the PCCs phenomena in the asymptotic region and the buoyant air flow phenomena on a vertical heated plate is derived. Using the similarity, the simplified heat transfer correlations for the interfacial heat fluxes and the ratios of latent heat transfer to sensible heat transfer were established. To verify the accuracy of the correlation, the results of this study were compared with those of other numerical analyses performed for the same configuration and they are well within the range of 15% difference.

  • PDF

Research of Energy Efficiency for Power Plant Performance Improvement (발전성능 향상을 위한 에너지 효율 연구)

  • Lee, Jae-Keun;Moon, Jeon-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.220-226
    • /
    • 2010
  • The heat transfer performance improvement in closed cooling water system of an electric power generation can be achieved by a corrosion control using corrosion inhibitors. The effect of trisodium phosphate and sodium nitrite upon carbon steel at various $Cl^{-1}$ ion containing water concentrations was examined by an integrated corrosion monitoring system. Nitrite was found to be the most effective inhibitor among tested inhibitors for carbon steel. The inhibiting process is considered as adsorption of nitrite ions in oxide layer which form a passive film on the carbon steel surface.

EVALUATION OF METHODOLOGY FOR AXISYMMETRIC SIMULATION OF RCCS IN VHTR (초고온가스로의 RCCS 해석을 위한 축대칭 모사 방법론 평가)

  • Kim, S.H.;Cho, B.H.;Tak, N.I.;Kim, M.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • RCCS is a passive safety-related system that removes the decay heat of VHTR when normal decay heat removal systems are in failure. Understanding thermo-hydraulics of RCCS is important to design a safer VHTR. RCCS consists of 292 cooling panels, which are placed in the reactor cavity. The layout of RCCS gives an idea that, for CFD simulations, cooling panels can be assumed to be one annulus tube. This assumption can reduce significantly the computational time, especially for the unsteady simulation. To simulate RCCS in an axisymmetric manner, three models were suggested and compared. Each model has (1) the same outer radius, (2) the same cross-sectional area (3) the same pressure drop, respectively, as the RCCS cooling panels. The steady-state simulation was conducted with these three models and the DO radiation model. It is found that over 90% of the heat from the outer wall of the reactor pressure vessel is transported to the RCCS by radiative heat transfer. The simulation with the third model, which has the same pressure drop as the design, estimates the closest wall temperature profiles to a thermo-hydraulic code, GAMMA+, result.

The Effect of Post Oxidation on Corrosion Characteristics of Gas Nitrocarburised Carbon Steels (Nitrocarburising 처리된 탄소강의 내식특성에 미치는 Post Oxidation 효과)

  • Kim, Y.H.;Jung, K.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.1
    • /
    • pp.9-20
    • /
    • 1999
  • The effect of post oxidation, water-quenched after holding in air for 5~420 seconds or cooling or furnace cooling, on corrosion resistance and phase formation characteristics of the surface layer of SM20C and SM45C carbon steels after gas nirtrocarbursing in the $NH_3-5%CO_2-N_2$ gas atmosphere at $580^{\circ}C$ for 3hours is studied. The compound layers of two steels consist of ${\varepsilon}-Fe_{2-3}N$, ${\gamma}^{\prime}-Fe_4N$ and $Fe_3O_4$, phases, however, the quantity of ${\gamma}^{\prime}-Fe_4N$ phase increases for the furnace cooled specimen compared to that of air cooling specimen. With increasing $NH_3$ content in the gas mixture and also increasing the keeping time in the air after gas nitrocarburising, the ${\varepsilon}-Fe_{2-3}N$ phase of compound layer increases, while the decreased current density recognizing the improvement of corrosion resistance are shown. the passive current density of SM45C steel is lower than that of SM20C steel at the same nitrocarburising conditions.

  • PDF

자연 에너지 이용과 환경건축을 위한 신기술

  • Lee, Gyeong-Hoe
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.107-119
    • /
    • 1993
  • This paper is to refine the concept of utilizing natural energy, and to introduce new technologies of building energy control. For the global environment protection, it is essential to turn attention to latent capacity of natural renewable energy. Especially the concept of 'Environmental Architecture' is very important from this viewpoint. This paper reviews many of new technologies for environmental architecture developed recently : TIM, high effective solar radiation control strategy of glazing, new passive cooling and heating system etc. The design application of the technology has been introduced.

  • PDF

Development of Liquid Metal Passive Cooling Flow Simulation System (액체금속 피동냉각유동모사 실증설비의 개발)

  • Ryu, Kyung-Ha;Kim, Jae-Hyoung;Lee, Tae-Hyun;Lee, Sang-Hyuk;Bahn, Byoung-Min
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.257-264
    • /
    • 2015
  • To maintain sustainability of nuclear energy as an important energy source, both safety problem and Spent Nuclear Fuels(SNFs) problem should be solved. In case of Gen-IV reactors such as fast reactor, SNFs can be used as fuels by using fast neutrons. It can be a suitable treatment method of high-level waste in near future. Liquid metals such as Sodium or Lead-Bismuth Eutectic (LBE) can be possibly used as a coolant to use fast neutrons. In this paper, it was described that natural circulation parameter studies, design analyses, material selections and a completion of facilities. To develop a natural circulation facility, thermal hydraulic analyses were performed. Installation technique of liquid metal natural circulation were secured.

CFD Analysis of a Concept of Nuclear Hybrid Heat Pipe with Control Rod (원자로 제어봉과 결합된 하이브리드 히트파이프의 CFD 해석)

  • Jeong, Yeong Shin;Kim, Kyung Mo;Kim, In Guk;Bang, In Cheol
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.109-114
    • /
    • 2014
  • After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of $B_4C$ pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type $B_4C$ pellet has an increasing tendency as heat input increases.

Heat Transfer in the Passive Containment Cooling System (수동형 격납용기 냉각계통에서의 열전달)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.281-291
    • /
    • 1995
  • The objective of this work is to obtain the experimental data for the heat transfer processes occurring both on the inside and outside surfaces of containment steel wall with dry and wet outer surface conditions in the passive containment cooling system. The test model represented a 60$^{\circ}$ section of a containment vessel based on the AP 600 geometry. Major linear dimensions of the test model ore reduced tv a factor of ten. To simulate the decay heat a steam generator heated by electricity was placed in the test model. The maximum heat flux was 8.91 kW/$m^2$. Two types of tests were performed. The one was the tort on the natural convection of air without water film flow. The other was the evaporative heat transfer test with the falling water film flow and natural air draft. no test result shooed that the heat transfer capability by the natural convection from the containment to the air without oater film flow was limited at about 1.48 kW/$m^2$ heat flux. It was found that the heat removal capability was remarkably enhanced in the tests with the waster film flow and air draft. The obtained heat transfer data ore compared with the existing correlations.

  • PDF

Experimental Investigation of Steam Condensation Heat Transfer in the Presence of Noncondensable Gas on a Vertical Tube (수직 튜브 외벽에서의 증기-비응축성 기체 응축 열전달 실험 연구)

  • Lee, Yeon-Gun;Jang, Yeong-Jun;Choi, Dong-Jae;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.42-50
    • /
    • 2015
  • To evaluate the heat removal capability of a condenser tube in the PCCS of an advanced nuclear power plant, a steam condensation experiment in the presence of noncondensable gas on a vertical tube is performed. The average heat transfer coefficient is measured on a vertical tube of 40 mm in O.D. and 1.0 m in length. The experiments covers the pressures of 2-4 bar, and the mass fraction of air ranges from 0.1 up to 0.7. From the experimental results, the effects of the total pressure and the concentration of air on the condensation heat transfer coefficient are investigated. The measured data are compared with the predictions by Uchida's and Tagami's correlations, and it is revealed that these models underestimate the condensation heat transfer coefficient of the steam-air mixture.

Numerical simulation of natural convection around the dome in the passive containment air-cooling system

  • Chunhui Dong;Shikang Chen;Ronghua Chen;Wenxi Tian;Suizheng Qiu;G.H. Su
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2997-3009
    • /
    • 2023
  • The Passive containment Air-cooling System (PAS) can effectively remove the decay heat of the modular small nuclear reactor after an accident. The details of natural convection around the dome, which is a key part of PAS, were investigated numerically in the present study. The thermal dynamics around the dome were studied through the temperature, pressure and velocity contours and the streamlines. Additionally, the formation of the buoyant plume at the top of the dome was investigated. The results show that with the increase of Ra, the lift-off point moves toward the bottom of the dome, and the eddy under the buoyant plume grows larger gradually, which enhances the heat transfer. And the heat transfer along the dome surface with different truncation angles was investigated. As the angle increases, the heat transfer coefficient becomes stronger as well. Consequently, a newly developed heat transfer correlation considering the influence of truncation angle for the dome is proposed based on the simulated results. This study could provide a better understanding of natural convection around the dome of PAS and the proposed correlation could also offer more predictive value in the improvement of nuclear safety.