• Title/Summary/Keyword: Passive and Active

Search Result 2,169, Processing Time 0.033 seconds

Antigenicity Studies of the Aqueous Extract of Red Ginseng in Guinea Pigs

  • Lee, Jong-Wha;Rhee, Man-Hee;Park, Ki-Hyun
    • Archives of Pharmacal Research
    • /
    • v.17 no.3
    • /
    • pp.154-160
    • /
    • 1994
  • The antigenicity of the aqueous extract of red ginseng (ARG) was evaluated using the following assay procedures : 1. active systemic anaphylaxis (ASA) in guinea pigs, 2 active cutaneous anaphylaxis (ACA) in guinea pigs, 3 passive cutaneous anaphylaxis (PCA) in guinea pigs, 2.active cutaneous anaphylaxis (ACA) in guinea pigs, 3. passive cutanepous anaphylaxis (PCA) in guina pigs with serum for guina pigs sensitized with ARG and 4. passive hemagglutination (PHA) with serum from guinea pigs sensitized with ARG. 1. ASA : No anaphylaxis reaction was observed in any of the sensitized guinea pigs by elictitation with ARG. 2. ACA : No skin reaction was observed in sensitized guinea pigs after intrademal injection of ARG. 3. PCA in guinea pigs : PCA titer of sera from all the sensitized animals was less than 10 in eliciation with ARG. 4. PHA reaction : When eythrocytes coated with challenge antigen were added to sensitized sera, the hemagglutination titer was less than 1. These results suggest that ARG has no antigenicity under the conditions used. And the dose levels of ARG employed in the present experiment were confirmed not to suppress immune reactions.

  • PDF

Coping Patterns in Chronic Low Back Pain : Relationship with Locus of Control and Self-Efficacy (만성 요통 환자의 대처 유형과 건강 통제위, 자기효능감과의 관계)

  • Kim, In-Ja;Lee, Eun-Ok
    • Journal of muscle and joint health
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • Coping patterns were investigated in a sample of 126 patients with chronic low back pain by means of self-reported questionnaire. Based on the previous researches, coping pat terns were divided into the active cognitive coping, the active behavioral coping, the passive cognitive coping, and the passive behavioral coping. While all the above coping patterns were used, the passive behavioral coping was found to be used most frequently. Six subgroups were identified by cluster analytic procedure using their scores of the coping scale : active cognitive coper, general active coper, passive behavioral coper, general passive coper, multidimensional coper, and multi dimensional non-coper. Six subgroups were compared regarding locus of control, self-efficacy, pain and demographic variables. Distinct differences appeared among subgroups in internal locus of control, self-efficacy, and pain. General active coper and active cognitive coper had higher internal locus of control, higher self-efficacy, and lower pain. General passive coper and multidimensional non-coper had lower internal locus of control, lower self-efficacy, and higher pain. Passive behavioral coper had higher internal locus of control, lower self-efficacy, and higher pain. It supports the concept of learned helplessness due to prior experiences. Multi dimensional coper had higher internal, higher powerful others, and higher self-efficacy. So it corresponds to 'believer in control' group Identified by Wallston et at(1982). Unexpectedly this group also complained more pain. It could be interpreted in two ways. The more coping methods they use, the more they complain pain ; which is the result of Folkman et al (1986). Or they might be typical 'yea sayers'. These unique groups-passive behavioral coper and multidimensional coper-identified by this study supports the suggestion of Wallston et al(1982), about locus of control : individual's pattern of responses across the three scales may be more predictive than his or her scores on each of the scale seperately. The fact that passive coping was used more than active coping also suggests that self controlled active co ping is encouraged to chronic patients as well as acute patients. And it is necessary to articulate the coping scale and self-efficacy scale. It is also necessary to study the relationship of coping and adjustment by experimental design.

  • PDF

Performance analysis of vehicle suspension systems with negative stiffness

  • Shi, Xiang;Shi, Wei;Xing, Lanchang
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.141-155
    • /
    • 2019
  • This work evaluates the influence of negative stiffness on the performances of various vehicle suspension systems, and proposes a re-centering negative stiffness device (NSD). The re-centering NSD consists of a passive magnetic negative stiffness spring and a positioning shaft with a re-centering function. The former produces negative stiffness control forces, and the latter prevents the amplification of static spring deflection. The numerical simulations reveal that negative stiffness can improve the ride comfort of a vehicle without affecting its road holding abilities for either passive or semi-active suspension systems. In general, the improvement degree of ride comfort increases as negative stiffness increases. For passive suspension system, negative stiffness brings in negative stiffness feature in the control forces, which is helpful for the ride comfort of a vehicle. For semi-active suspensions, negative stiffness can alleviate the impact of clipped damping in semi-active dampers, and thus the ride comfort of a vehicle can be improved.

Experimental Study on the Performance of a Semi-Active Orificed Fluid Damper (반능동형 오리피스 유체댐퍼의 성능 실험)

  • 문석준;김병현;정종안
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.387-394
    • /
    • 2003
  • A compromise between passive and active control systems has been developed recently in the form of semi-active control systems. Semi-active control systems maintain the reliability of passive control systems while taking advantage of the adjustability of an active control system. This paper presents the results of an experimental study to evaluate the performance of a semi-active orificed fluid damper. The semi-active orificed fluid damper considered is a two-stage damper with normally open solenoid valve. Through a series of experimental tests, characteristics and performance of the damper is investigated.

  • PDF

Target Motion Analysis for Active/Passive Mixed-Mode Sonar Systems

  • Taek, Lim-Young;Lyul, Song-Taek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.172.5-172
    • /
    • 2001
  • Target Motion Analysis(TMA) for Passive Sonar Systems with bearing-only measurements needs to enhance system observability to improve target tracking performance by ownship maneuvering. However, tracking problem incurred by weak observaility result in slow convergence of the target estimates. On the other hand, active sonar systems do not have problem associated with system observaility. However, it drawback related to system survivability. In this paper, the algorithm that could be used in Active/passive Mixed-Mode Sonar Systems is proposed to analyze maneuvering target motion and to improve TMA performance. The proposed TMA algorithm is tested by a series of computer simulation runs and the results ...

  • PDF

Antigenicity Studies of the Aqueous Extract of Fresh Ginseng in Guinea Pigs

  • Lee, Jong-Wha;Rhee, Man-Hee;Park, Jong-Il;Han, Sang-Seop
    • Korean Journal of Pharmacognosy
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 1994
  • Aqueous extreact of fresh ginseng (AFG) was examined for the antigenicity in Hartley guinea pigs in comparision with ovalbumin (OVA). When guinea pigs were sensitized with AFG emulsified with complete Freund's adjuvant (CFA), these animals showed negative reactions in active systemic anaphylaxis (ASA), active cutaneous anaphylaxis (ACA) and passive cutaneous anaphylaxis (PCA) tests and passive hemagglutination (PHA) reaction. On the contrary, when guinea pigs were sensitized with OVA emulsified with CFA as positive controls, these animals disclosed positive reactions in ASA, ACA and PCA tests and PHA reaction. From these results, AFG was considered not to possess antigenic properties in guinea pigs. In addition, the dose levels of AFG empolyed in the present experiment were confirmed not to suppress immune reactions.

  • PDF

Series Hybrid Active Filter

  • Kim, Won-Ho;Kim, Jong-Soo;Kang, Iou-Ri;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.271-273
    • /
    • 1995
  • Hybrid active filters utilize passive filters to reduce the voltage rating and hence the VA rating of the active filter converter. A novel hybrid active filter topoloty to minimize utility current harmonics at high power levels is presented in this paper. The proposed topology combines both passive and active filters to obtain the lowest converter VA rating as compared to the converter rating in the active filter and the series-active hybrid filter configurations. This is demonstrated with experimental results from a laboratory model. Simulation results showing the effect of passive filter impedance are presented.

  • PDF

Seismic response control of elastic and inelastic structures by using passive and semi-active tuned mass dampers

  • Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan
    • Smart Structures and Systems
    • /
    • v.8 no.3
    • /
    • pp.239-252
    • /
    • 2011
  • In this study, the performances of a passive tuned mass damper (TMD) and a semi-active TMD (STMD) were evaluated in terms of seismic response control of elastic and inelastic structures under seismic loads. First, elastic displacement spectra were obtained for damped structures with a passive TMD and with a STMD proposed in this study. The displacement spectra confirmed that the STMD provided much better control performance than passive TMD and the STMD had less stroke requirement. Also, the robustness of the TMD was evaluated by off-tuning the frequency of the TMD to that of the structure. Finally, numerical analyses were conducted for an inelastic structure of hysteresis described by the Bouc-Wen model. The results indicated that the performance of the passive TMD whose design parameters were optimized for an elastic structure considerably deteriorated when the hysteretic portion of the structural responses increased, and that the STMD showed about 15-40% more response reduction than the TMD.

Active and Passive Protective Effect of CFC-101 (Pseudomonas Vaccine) in Mice (CFC-101(녹농균 백신)의 능동 및 수동면역 효과)

  • 박완제;조양제;김영지;김제학;박관하;김유삼;함경수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.326-330
    • /
    • 1994
  • The treatment of pseudomonal infection is a perplexed problem because of its modest susceptibility to most of the major antibiotics. A novel Pseudomonas vaccine(CFC-101) was prepared from the outer membrane protein fractions of several Pseudomonas strains. In this study, we examined CFC-101's effectiveness in both active and passive immunization models. CFC-101 in mice at 0.2 mg/kg, i.p., given three times at two-day intervals, completely prevented the death caused by Pseudomonas aeruginosa. Antibody titer, in accordance with the protective effect in this active immunization, was elevated to its peak level following three consecutive administrations of CFC-101. Thereafter, antibody titer stayed at a constantly high level. Each outer membrane protein fraction from the four CFC-101 producers, exhibited good cross-protective effects in mouse infection models against different Fisher types of P. aeruginosa. In the passive immunization model, 21~336 $\mu\textrm{g}$/kg of anti-rabbit IgG to CFC-101, when mice being infected with a challenge strain, prevented the Pseudomonhas-induced death up to 60%. Therefore, the preventive effect of CFC-101 was verified in both the active and passive immunization models.

  • PDF

Development of the Passive-Active Vibration Absorber Using Piezoelectric Actuators (수동-능동 압전형 진동흡수장치의 개발)

  • Kwak, Myung-Hoon;Heo, Seok;Kwak, Moon-K
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.308-312
    • /
    • 2001
  • This research is concerned with development of the passive-active vibration absorber using piezoelectric actuators. This active-passive isolation system consists of 4-pairs of PZT actuators bonded on accordion type of mounting bracket and a spring-damper located in center. Hence, the active system is connected in parallel to the passive system. In this paper, we discuss the dynamic characteristics of the addressed system. Based on the series of experiment, it is found that the proposed system can cope with the external disturbances. The controller design is currently under investigation.

  • PDF