단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

수동형 필터 적용시 무효전력의 변화에 관한 연구 (Study on the Variation of Reactive Power When Applying the Passive Filter)

  • 김지명;김종겸
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

Factor Graph-based Multipath-assisted Indoor Passive Localization with Inaccurate Receiver

  • Hao, Ganlin;Wu, Nan;Xiong, Yifeng;Wang, Hua;Kuang, Jingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권2호
    • /
    • pp.703-722
    • /
    • 2016
  • Passive wireless devices have increasing civilian and military applications, especially in the scenario with wearable devices and Internet of Things. In this paper, we study indoor localization of a target equipped with radio-frequency identification (RFID) device in ultra-wideband (UWB) wireless networks. With known room layout, deterministic multipath components, including the line-of-sight (LOS) signal and the reflected signals via multipath propagation, are employed to locate the target with one transmitter and a single inaccurate receiver. A factor graph corresponding to the joint posterior position distribution of target and receiver is constructed. However, due to the mixed distribution in the factor node of likelihood function, the expressions of messages are intractable by directly applying belief propagation on factor graph. To this end, we approximate the messages by Gaussian distribution via minimizing the Kullback-Leibler divergence (KLD) between them. Accordingly, a parametric message passing algorithm for indoor passive localization is derived, in which only the means and variances of Gaussian distributions have to be updated. Performance of the proposed algorithm and the impact of critical parameters are evaluated by Monte Carlo simulations, which demonstrate the superior performance in localization accuracy and the robustness to the statistics of multipath channels.

형광등용 전자식 안정기에서 수동 역율 보상회로의 특성 및 개선 (Characteristic and Improvement of Passive PFC with Electronic Ballast for Fluorescent lamp)

  • 박종연;이혁순
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.311-314
    • /
    • 2002
  • In recent years, various power factor correction(PFC) circuits for the electronic ballasts have been proposed. In this paper, we have studied several passive PFC and compared with their characteristics, used in the electronic ballast for fluorescent. Especially, Improved Valley Fill Circuit (IVF) and the circuit IVF PFC combined with Charge Pumping Capacitors(CPCs) have been reaserched for High Power Factor. In conclusion, we have researched characteristics of Passive PFC and proposed the most effective PFC method.

  • PDF

폐광지역에서의 싱크홀 발생 규명을 위한 Active-Passive-Active 유한요소 기법 연구 (Analysis of Sinkhole Formation over Abandoned Mine using Active-Passive-Active Finite Elements)

  • ;신희순;최성웅
    • 터널과지하공간
    • /
    • 제14권6호
    • /
    • pp.411-422
    • /
    • 2004
  • 폐광지역에서 흔히 발생하는 싱크홀 형태의 지반침하는 인근 지역 주민의 안전은 물론, 지상구조물에 심각한 위해 요소로 작용할 수 있다. 본 연구에서는, 이러한 싱크홀의 발생양상을 수치해석적으로 규명하기 위해, 아주 특별한 형태의 유한요소해석을 실시하였다. 특히, 갱도 천반의 붕락에 의해 야기되는 공간이나, 파쇄된 암반이 쌓여서 이루는 폐석더미 등 기존의 수치해석기법으로서는 쉽사리 표현할 수 없었던 현실적인 문제들을 수치적으로 모사하기 위해 active-passive-active 유한요소를 사용하였다. Active 요소 즉 고체 요소는 싱크홀이 형성되는 영역 내에서 인장파괴 기준식을 만족하게 되면 passive 요소 즉 공간 요소로 전환될 수 있다. 싱크홀이 완전히 형성되게 되면 이들 passive요소들은 다시 active요소로 바뀌면서 폐석더미를 수치적으로 모사할 수 있게 된다. 채굴적의 폭, 심도, 천반의 상태 및 붕락 암반의 부피팽창율 등이 싱크홀에 미치는 영향을 검토하기 위해 여러 가지 조건에 의한 유한요소모델이 해석되었다. 본 연구는, 이와 같이 싱크홀이 발생하는 과정이나 천반이 붕락하는 현상 등을 해석하기 위해 수치해석상에서 active-passive-active유한요소들이 효과적으로 사용될 수 있음을 보여준다.

고조파 저감을 위한 수동필터의 제어시스템에 관한 연구 (A Study on the Control System of Passive Filter to Reduce Harmonics)

  • 전정채;유재근;이상익
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.124-130
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 개$.$폐할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 개ㆍ폐 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 개$.$폐하게 된다. 이러한 제어시스템을 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 전동기 운전조건에 따라 수동필터를 개$.$폐시키며 고조파 및 무효전력 등을 측정함으로써 성능을 입증하였다.

Tobacco Smoke Exposure and Breast Cancer Risk in Thai Urban Females

  • Pimhanam, Chaisak;Sangrajrang, Suleeporn;Ekpanyaskul, Chatchai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7407-7411
    • /
    • 2014
  • The incidence of urban female breast cancer has been continuously increasing over the past decade with unknown etiology. One hypothesis for this increase is carcinogen exposure from tobacco. Therefore, the objective of this study was to investigate the risk of urban female breast cancer from tobacco smoke exposure. The matched case control study was conducted among Thai females, aged 17-76 years and living in Bangkok or its surrounding areas. A total of 444 pairs of cases and controls were recruited from the Thai National Cancer Institute. Cases were newly diagnosed and histologically confirmed as breast cancer while controls were selected from healthy women who visited a patient, matched by age ${\pm}5$ years. After obtaining informed consent, tobacco smoke exposure data and information on other potential risk factors were collected by interview. The analysis was performed by conditional logistic regression, and presented with odds ratio (ORs) and 95% confidence intervals(CI). From all subjects, 3.8% of cases and 3.4% of controls were active smokers while 11.0% of cases and 6.1% of controls were passive smokers. The highest to lowest sources of passive tobacco smoke were from spouses (40.8%), the workplace (36.8%) and public areas (26.3%), respectively. After adjusting for other potential risk factors or confounders, females with frequent low-dose passive smoke exposure (${\leq}7$ hours per week) from a spouse or workplace had adjusted odds ratio 3.77 (95%CI=1.11-12.82) and 4.02 (95%CI=1.04-15.50) higher risk of breast cancer compared with non-smokers, respectively. However, this study did not find any association of breast cancer risk in high dose passive tobacco smoke exposure, or a dose response relationship in cumulative passive tobacco smoke exposure per week, or in the active smoker group. In conclusion, passive smoke exposure may be one important risk factor of urban female breast cancer, particularly, from a spouse or workplace. This risk factor highlights the importance of avoiding tobacco smoke exposure as a key measure for breast cancer prevention and control.

에너지재생 수동스너버를 갖는 고역율 부스트 정류기 (High-Power-Factor Boost Rectifier with a Passive Energy Recovery Snubber)

  • 김만고;백승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.428-432
    • /
    • 1998
  • A passive energy recovery snubber for high-power-factor boost rectifier, in which the main switch is implemented with a MOSFET, is described in terms of the equivalent circuits that are operational during turn-on and turn-off sequences. The main switch combined with proposed snubber can be turned on with zero current and turned off at limited voltage stress. The high-power-factor boost rectifier with proposed snubber is implemented, and the experimental results are presented to confirm the validity of proposed snubber.

  • PDF

LC 병렬공진을 이용한 고효율 장수명 LED 구동회로 설계 (The Design of Long-life and High-efficiency Passive LED Drivers using LC Parallel Resonance)

  • 이은수;최보환;천준필;김봉철;임춘택
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.397-402
    • /
    • 2013
  • This paper proposes a new passive type LED driver which satisfies the standard of power factor (PF) and total harmonic distortion (THD). The proposed passive LED driver also has high-efficiency and long-life time characteristics compared to active LED driver which is composed of op-amp, switches and so on. By using just passive components such as inductor, capacitor, and diode, it has resolved extremely short-life time and low-efficiency problems of previous LED drivers. It has achieved PF of 0.99, THD of 16.4 %, and the total efficiency of 95 %. The proposed passive LED driver is fully analyzed and verified by simulations and experiments, which results are in good agreement each other.