• Title/Summary/Keyword: Passive Balancing

Search Result 34, Processing Time 0.032 seconds

A Study on the Healing Interface around Void space of Contemporary Houses (현대주택의 허공간 주변의 치유적 인터페이스에 관한 연구)

  • Kim, Jinhee;Kim, Kwangho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2016
  • Purpose: Planning space of the house is important as a universal place to relieve stress of contemporary people. Void space is easy to perform mental and cultural programs in aspect of affording the healing behavior. The "Interface" accommodates healing behaviors through mutual interchange between void space and solid space as the edge of the solid space around void space. This study presents a efficient theory of healing space through combining space theory with the Kitwood's theory of psychiatry used for the art therapy. Methods: Spatial elements based on Kitwood's theory converges towards 2 behavioral elements; Meditation(-), Sense of Community(+). Balancing with reciprocal complement between behaviors of passive and stable "Meditation(-)" and active and released "Sense of Community(+)" was analysed. Results: "Faciliation" can be used in combination with "Flow(+)" as active factor. "Validation" is combined with "Prospect(+,-)", and divides into 2 factor ; "Recognition-Refreshment(-)", "Reaction-Social Exchange(+)". "Holding" is combined with "Refuge(-)" as passive factor. Implications: This study established concept of spatial healing elements in connection with theory of Psychiatry about Alzheimer that is extreme situation of stress. This study is expected to enhance the validity and efficiency in analysis of healing space.

Relationships between optimal number of wavelenghs and tuning time in WDM/TDM passive star network (WDM 수동성형성망에서의 TDM 스케쥴링시 최적파장수와 파장조정시간과의 관계)

  • 신홍섭;신용식;박구현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1785-1796
    • /
    • 1998
  • This paper is concerned with the relationships between optimal number of wavelengths and tuning time in time division multiplexing(TDM) scheduling on wavelength division multiplexing(WDM) optical passive star networks. We assume that the traffic is nonuniform and each node has a tunable transmitter and a fixed receiver. Each node transmits spckets to all other nodes. Most of the earlier protocols on TDM based scheduling for WDM star networks [7, 8, etc.] use whold given wavelength chnnels. But in this paper, we investigate the optimal number of wavelengths that yidels minimum frame length when tuning time exists. It appears within the availble number of wavelengths that yields minimum frame length when tuning time exists. It appears within the available number of wavelengths. We analyze the relationships between optimal number of wavelengths and tuning time by experiments. We analyze the reationships between optimal number of wavelengths and tuning time by experiments. We also discuss on the possibility of reduction of frame length by increasing the number of nodes trans-mitters and receivers.

  • PDF

Numerical Study on the Effect of Cavity Vanes to Control the Axial Thrust of a Turbopump (터보펌프 축추력 조절용 캐비티 베인에 대한 수치해석적 연구)

  • Choi, Chang-Ho;Kim, Jin-Han;Noh, Jun-Gu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.39-43
    • /
    • 2006
  • The magnitude of the axial force acting on turbopump bearings has a great influence on the operational reliability and service life of a turbopump. In the turbopump under current investigation the cavity vanes are introduced to the pump shroud casing to control the axial thrust of the turbopump. To investigate the effect of the cavity vanes, 3D computational flow analyses for a propellant pump stage including an inducer, impeller, volute and secondary flow passages are performed with and without the vanes. The results show that the cavity vanes are very effective in reducing the magnitude of axial thrust without notable changes on the overall performance of the turbopump.

회전체 진동감소를 위한 마그네틱 댐퍼 설계 및 응용

  • 이봉기;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.769-772
    • /
    • 1995
  • Most turbo machines, which operate at high speeds, such as gas turbines, jet engines, pumps, and compressors are prone to perrturbing vibrations. The best vibration control method for rotors is to eliminate destabilizing factors. Careful balancing application of "more stable" oil-lubricated bearing, such as tilting pad bearings or use of anti-swirl devices in seals, are examplse of passive vibration control methods. the use of magnetic bearing is an active control method. An obvious advantage of active control is that it provides damping (or modifies system stiffness or other parameters) only when there is a need for that, i.e., in emergency states, while not affecting the rotor normal operational conditions. Moreover, active control methods provide exact position control through on-line control. In this study, a magnetic actuator, digital contrliier using DSP, and bipolar operational power supply/amplifiers were developed to show the effectiveness of reducing robot vibration. Also the curve fitting procedure to obtain the transfer function of frequency dependent component was developed. Results presented in this dissertation will provide a well-defined technical parameters in designing magnetic damper system.er system.

  • PDF

Development of Balancer for Reduced Vibration of Washing Machine (세탁기의 진동 감소를 위한 밸런서 개발)

  • 폴위즈바;웨이지아카오;박정수;김형균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.602-607
    • /
    • 1997
  • Ball balance belong to a kind of automatic balancers opten referred to as direct balancer or passive mass systems. In such systems the balancing is achieved with free masses. One of the most prevalent problems encountered in washing is the vibration during spin cycle. The primary cause of this vibration is mass unbalance associated with non unform distribution of clothes. Front loading type machine of European style, especially, has inherent unbalance mass due to its shape and this then makes the vibration worse than top loading type machine, which is more popular in Korea. Since the mass distribution of cloths is random and can not be predicted in advance, direct automatic balances appear to be the only feasible alternative. The results form computer simulation and experimental testing will be presented together with stability implications.

  • PDF

Numerical Study on the Effect of Cavity Vanes to Control the Axial Thrust of a Turbopump (터보펌프 축추력 조절용 캐버티 베인에 대한 수치해석적 연구)

  • Noh, Jun-Gu;Choi, Chang-Ho;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.354-358
    • /
    • 2005
  • The magnitude of the axial force acting on turbopump bearings has a great influence on the operational reliability and service life of a turbopump. In the turbopump under current investigation the cavity vanes are introduced to the pump shroud casing to control the axial thrust of the turbopump. To investigate the effect of the cavity vanes, 3D computational flow analyses for a propellant pump stage including an inducer, impeller, volute and secondary flow passages are performed with and without the vanes. The results show that the cavity vanes are very effective in reducing the magnitude of axial thrust without notable changes on the overall performance of the turbopump.

  • PDF

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.

Study on the Pressure Balance of the Hybrid Safety Injection Tank (피동충수용 혼합형 안전주입탱크의 압력평형에 관한 이론적 해석 및 시험적 연구)

  • Ryu, Sung Uk;Ryu, Hyobong;Byun, Sun-Joon;Jeon, Woo-Jin;Park, Hyun-Sik;Lee, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.185-191
    • /
    • 2016
  • The Hybrid Safety Injection Tank is a passive safety injection system that enables the safety injection water to be injected into the reactor pressure vessel throughout all operating pressures by connecting the top of the SIT and the pressurizer(PZR). In this study, the condition for balancing the pressure between the Hybrid SIT and PZR was derived theoretically. The pressure balancing condition was set at the point where the velocity of the Hybrid SIT coolant injected into the Direct Vessel Injection(DVI) line was at or above zero. If the condition was derived from a pressure network for the Hybrid SIT, pressurizer, and reactor pressure vessel, the pressure difference between the pressurizer and SIT is less than 0.07 MPa.

A Study of Evaluation Model for RPG Combat Balance in Mobile (RPG 전투밸런스 평가모델 연구 : 모바일 게임 중심으로)

  • Jeon, Joon Hyun;Jeong, Eui Jun
    • Journal of Korea Game Society
    • /
    • v.15 no.4
    • /
    • pp.49-58
    • /
    • 2015
  • Due to the improving mobile environments, we can play RPG in not only computer online field but also mobile field. It is difference from hardware environment between them so that mobile RPG has been changed and modified to play in mobile environment except RPG's frame and basic element. This Study has investigated the model to evaluate the balance of battle that is based on the RPG. Although there is an assessment model studied with a focus on the MMORPG, It is difficult to apply to the entire balance in RPG especially mobile RPG. Former model has used only basic element because there were so many kinds of variables such as user's controls, other players and objects in game. The reason why that model just gave a guide line about battle balance. In this paper, the new assessment model to include the balance factors such as BUFF, NURF and PASSIVE could be possible for applying the balance of mobile RPG on recent trends. As a result, the new model can measure numerical calculations compared to the previous model.

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.