• Title/Summary/Keyword: Passive & Active Elements

Search Result 96, Processing Time 0.037 seconds

Combination Effects of Self-Volar Gliding Using a Strap and Wrist Distraction on Pain and Wrist Extension Range of Motion in Subjects with Dorsal Wrist Pain

  • Kim, Ki-Song;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.5
    • /
    • pp.286-291
    • /
    • 2019
  • Purpose: This study examined the effects of self-volar gliding combined with a strap and wrist distraction on pain and the active and passive wrist extension range of motion (ROM) in subjects with dorsal wrist pain during partial weight bearing of the hand. Methods: Thirty subjects (14 males and 16 females) with dorsal wrist pain during partial weight bearing through the hand participated in this study. The two different self-volar gliding techniques were performed for each group. Self-volar gliding using a strap (SVGS) and SVGS and wrist distraction (SVGSD) were performed five times for one week for each group. The active and passive ROM of wrist extension and the peak pressure pushed by the hand at pain (PPHP) were measured. An independent t-test was used to compare the improvements of these elements between the two different self-volar gliding techniques. The level of statistical significance was at ${\alpha}=0.05$. Results: The active and passive ROM of wrist extension and PPHP were greater in both self-volar gliding groups after the one week intervention. On the other hand, these parameters were greater in the SVGSD group than in the SVGS group (p<0.05) Conclusion: SVGSD is recommended to improve the active and passive ROM of wrist extension and PPHP in subjects with dorsal wrist pain during partial weight bearing of the hand.

A Comparative Study on the Dynamic Characteristics and Control Performances of Hybrid Mounts According to Element Configuration (배치형식에 따른 복합형 마운트의 동특성 및 제어성능에 대한 비교연구)

  • Cho, H.Y.;Moon, S.J.;Shin, Y.H.;Jung, W.J.;Won, M.C.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.6
    • /
    • pp.556-563
    • /
    • 2012
  • This study focuses on the element configuration of hybrid mounts which are combined with passive elements and active elements. The seven configurations are presented according to connection of an active element to a passive element. The dynamic characteristics and control performance of them are investigated qualitatively using Bode plots. With reference to the transmitted force from internal to external, three cases are selected. In addition, some numerical simulations for the three cases are carried out to confirm the performance quantitatively. Based on this research results, a novel hybrid mount with excellent performance will be able to be developed.

Deriving Priorities Based on Combination of Green Remodeling Application Elements in Old Public Libraries (노후 공공도서관의 그린리모델링 적용 요소 조합에 따른 우선순위 도출)

  • Sung Jin Sim;Se Hyeon Lim;Seong Eun Kim;Yong Woo Song
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2024
  • The Ministry of Land, Infrastructure, and Transport has been promoting strengthening energy efficiency of old buildings through public green building remodeling projects since 2020. Green remodeling includes both essential and optional construction of passive and active elements. However, there is a lack of integrated designs of passive and active systems and no standards for prioritizing these systems according to the building's age. Therefore, this study examined six public libraries in central region 2 that were expected to be high energy consuming. Remodeling strategy priorities were selected based on potential energy reduction. The libraries were divided into three groups based on their year of construction, completed in the 1980s (Model 1), 1990s (Model 2), and 2000s (Model 3). ECO2-OD, based on ISO 13790 and DINV 18599, was used as the primary energy consumption analysis tool. Simulation results indicated Model 1 and Model 2 benefited most from higher insulation and replacement of mechanical equipment. Model 3 benefited most from upgrading to more energy efficient windows.

The Effect of Alloying Elements and Heat Treatment on the Uniform Corrosion of 440A Martensitic Stainless Steel(I) (440A 강의 균일부식에 미치는 합금원소와 열처리의 영향(I))

  • Kim, Y.C.;Kang, C.Y.;Jung, B.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.42-48
    • /
    • 2011
  • 440A martensitic stainless steels which were modified with reduced carbon content(~0.5%) and addition of small amount of nickel, vanadium, tungsten and molybdenum were manufactured. Effects of alloying elements and tempering temperatures on the uniform corrosion in the solution of lN H2S04 were investigated through the electrochemical polarization test. When tempering temperature is constant, corrosion current density in active-passive transition point, Icorr, decreased a little with an increase of austenitizing temperature. In addition to this, when austenitizing temperature is constant, longer holding time showed a little lower Icorr and Ipass, passive current density. And when austenitized at $1050^{\circ}C$ and tempered in a range of $350{\sim}750^{\circ}C$, best anti-corrosion properties were obtained at $350^{\circ}C$ tempering temperature while worst at $450^{\circ}C$ or $550^{\circ}C$. The specimens tempered at below $450^{\circ}C$ and above $550^{\circ}C$, similar and good anti-corrosion characteristics were obtained regardless of alloying elements added, showing anti-corrosion characteristics are influenced more by tempering temperature than by alloying elements.

A Study on the Investment Review of Passive and Active Elements through Comparison of Energy Demand and Generation Variation of Zero Energy Building (제로에너지건축물의 에너지 소요량과 생산량 비교를 통한 패시브와 액티브 요소의 투자 검토 연구)

  • Lee, Soon-Myung;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.13-22
    • /
    • 2018
  • At the time when zero energy building is expected to be generalized, this study examines whether the investment in the passive element or the active element is more effective in terms of energy in the construction process of zero energy building. In other words, the effect of energy demand by passive element and the change of energy generation by active element are examined in terms of the same investment cost. The purpose of this study is to examine the change of energy demand by passive element and the change of energy generation by active element in zero energy building and to make reasonable investment decision by comparing energy with cost aspect. For this purpose, we selected the buildings to be subjected to energy simulation and derive the required energy amount and energy generation amount by using meteorological data of four regions in Korea. The change of energy demand and energy generation according to the change of application condition was derived. In order to compare and analyze the changes in energy demand and generation at the same cost standard through price survey and quotation of window and photovoltaic power generation equipment.

A Study on the Healing Interface around Void space of Contemporary Houses (현대주택의 허공간 주변의 치유적 인터페이스에 관한 연구)

  • Kim, Jinhee;Kim, Kwangho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2016
  • Purpose: Planning space of the house is important as a universal place to relieve stress of contemporary people. Void space is easy to perform mental and cultural programs in aspect of affording the healing behavior. The "Interface" accommodates healing behaviors through mutual interchange between void space and solid space as the edge of the solid space around void space. This study presents a efficient theory of healing space through combining space theory with the Kitwood's theory of psychiatry used for the art therapy. Methods: Spatial elements based on Kitwood's theory converges towards 2 behavioral elements; Meditation(-), Sense of Community(+). Balancing with reciprocal complement between behaviors of passive and stable "Meditation(-)" and active and released "Sense of Community(+)" was analysed. Results: "Faciliation" can be used in combination with "Flow(+)" as active factor. "Validation" is combined with "Prospect(+,-)", and divides into 2 factor ; "Recognition-Refreshment(-)", "Reaction-Social Exchange(+)". "Holding" is combined with "Refuge(-)" as passive factor. Implications: This study established concept of spatial healing elements in connection with theory of Psychiatry about Alzheimer that is extreme situation of stress. This study is expected to enhance the validity and efficiency in analysis of healing space.

Shock Absorbing Safe Mechanism Based on Transmission Angle of a 4-bar Linkage (4절링크의 전달각에 기초한 충격흡수식 안전 메커니즘)

  • 박정준;김병상;송재복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.180-185
    • /
    • 2004
  • Unlike industrial manipulators, the manipulators mounted on the service robots are interacting with humans in various aspects. Therefore, safety has been the important design issue. Many compliant robot arm designs have been introduced for safety. It is known that passive compliance method has faster response and higher reliability than active ones. In this paper, a new safe mechanism based on passive compliance has been proposed. Passive mechanical elements, specifically transmission angle of the 4-bar linkage, springs and shock absorbing modules are incorporated into this safe mechanism. This mechanism works only when the robot arm exerts contact force much more than the human pain tolerance. Validity of the safe mechanism is verified by simulations and experiments. In this research, it is shown that the manipulator using this mechanism provides higher performance and safety than those using other passive compliance mechanisms.

  • PDF

Study on Performance Improvement and Size Reduction Using Active Inductors in MMIC Frequency Converter (능동인덕터 사용에 따른 MMIC 주파수 변환기의 성능향상과 면적축소에 관한 연구)

  • 구현철;박정호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1296-1303
    • /
    • 1994
  • In this paper, a design of active inductors and their application in a frequency converter are proposed. In MMIC design, passive spiral inductor takes larger area than any other passive and active elements. A conventional spiral inductor generates undesired crosstalk, and its performance cannot have certainty and reproducibility. Meanwhile the active inductor eliminates these drawbacks, and operates for much wider bandwidth. Furthermore, its size is smaller and nearly independent of inductance. the performance of MMIC frequency converter with active inductors is directly compared with that of the frequency converters with spiral inductors. The size is 28.6% smaller with better performance in MMIC frequency converter.

  • PDF

Current-Mode Electronically Tunable Universal Filter Using Only Plus-Type Current Controlled Conveyors and Grounded Capacitors

  • Minaei, Shahram;Turkoz, Sait
    • ETRI Journal
    • /
    • v.26 no.4
    • /
    • pp.292-296
    • /
    • 2004
  • In this paper we present a new current-mode electronically tunable universal filter using only plus-type current controlled conveyors (CCCII+s) and grounded capacitors. The proposed circuit can simultaneously realize lowpass, bandpass, and highpass filter functions - all at high impedance outputs. The realization of a notch response does not require additional active elements. The circuit enjoys an independent current control of parameters $\omega_0$ and $\omega_0/Q$. No element matching conditions are imposed. Both its active and passive sensitivities are low.

  • PDF

An Active-Only Voltage-Mode Integrator and Its Applications

  • Shinji, Ohyama;Kim, Doh-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.158.4-158
    • /
    • 2001
  • This paper presents a novel circuit configuration for realizing the continuous-time active-only voltage-mode integrator. The proposed integrator consists only of internally compensated type operational amplifier (OA) and operational transconductance amplifiers (OTAs). Since no external passive elements are required, the integrator is suitable for integrated circuit implementation in either bipolar or CMOS technologies. Moreover, the integrator gain can be electronically tuned by adjusting the bias currents of the OTAs. The characteristics of the proposed integrator and the effectiveness of the design procedure in realizing various analog transfer functions have been examined by PSPICE simulation.

  • PDF