• 제목/요약/키워드: Passed tests

검색결과 148건 처리시간 0.019초

어깨가슴운동과 등뼈가동운동이 어깨돌림근띠 파열을 가진 환자들의 통증과 기능장애에 미치는 영향 (The Effect of Scapulothoracic Exercise and Thoracic Mobilization on Shoulder Pain and Function in Shoulder Partial Thickness Rotator Cuff Tear)

  • 김동현;김명철
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.41-51
    • /
    • 2020
  • Purpose : The purpose of this study was to determine the effect of scapulothoracic exercise and thoracic mobilization on shoulder pain and function in individulas with shoulder partial- thickness rotator cuff tear. Methods : Forty-five subjects were recruited and randomly divided into 3 groups of 15 subjects each : Scapulothoracic exercise with Thoracic mobilization (STwTM), Scapulothoracic exercise (ST), and Thoracic mobilization (TM) groups. All subjects were assessed for pain and disability of shoulder, thoracic angle base on the Shoulder Pain and Disability Index (SPADI) and Thoracic kyphosis assessment (TKA) using Baseline Bubble Inclinometer. All groups performed 50 minutes of the intervention twice a week for a total of six weeks. These tests were evaluated Three times : prior to the start of the intervention, after three weeks and, after six weeks had passed. Results : The SPADI score showed that pain and dysfunction in the STwTM group decreased compared to those in the other two groups. The TKA score showed a decrease over time in the ST, TM, and STwTM groups, in increasing order. However, the TKA score decreased significantly in the STwTM group compared to that in the oher two groups. Conclusion : ST and TM are effective in improving pain and dysfunction in patients. However, STwTM may be more effective for patients.

대형 트럭용 경량 알루미늄 I형 래디어스 로드 개발 (Development of Lightweight Aluminum I Type Radius Rod for Heavy Trucks)

  • 최규재;이기녕;하태수
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.58-64
    • /
    • 2008
  • An aluminum radius rod using rheo-forging method has been developed for heavy commercial vehicles to decrease vehicle unsprung weight. To design the shape of the rod, structural simulations are performed using two load cases. To evaluate durability performance of the rods, a test system which has simultaneous 3 axes actuating system is developed. And 3 axes durability test conditions are established based on vehicle field tests. Using the test systems and the conditions, the durability test is carried out and the rods have passed the test conditions of 700,000 cycles. The weight of a developed aluminum radius rod is 4.2kg and it was drastically reduced by 48.8 percent in comparison with the weight of a steel radius rod.

틸팅열차 주행시 곡선부 궤도에서의 동적상호작용 (Dynamic Interaction Analysis of Tilting Train and Curved Track)

  • 정근영;고태훈
    • 한국철도학회논문집
    • /
    • 제15권2호
    • /
    • pp.162-171
    • /
    • 2012
  • 본 연구에서는 곡선부를 주행하는 틸팅열차와 궤도와의 동적상호작용을 고려한 동적해석을 수행하기 위한 해석기법을 제시하였다. 본 연구에서는 3차원 차량요소를 이용하여 틸팅열차를 모형화하였으며, 틸팅열차의 곡선부 주행시 차량의 주행방향이 크게 변화하는 상황에서 주행속도 및 원곡선 반경에 상응하는 원심력의 표현, 선로의 캔트량, 차륜-레일의 접촉각 및 열차의 틸팅각 등을 고려한 동적상호작용해석 방법을 제안하였다. 제안된 해석방법은 기본적인 검증예제들에서 만족할만한 결과를 보여주었으며, 실제적인 문제에 적용이 가능할 것으로 기대된다.

Evaluation Criteria of Reliability on Transmission Control Unit for Passenger Car

  • Choi, M.;Ryu, S.;Lim, J.H.;Jeong, H.S.
    • International Journal of Reliability and Applications
    • /
    • 제11권1호
    • /
    • pp.55-67
    • /
    • 2010
  • There has been a recent upsurge in demand for the improvement of car reliability in the Northern American which is the primary market of South Korea automobile industry. It has been required that the warranty for transmission control unit for passenger cars directly related to passenger safety or security should be extended for 10 years and 160,000 km. In this paper, the test method for reliability and evaluation criteria is presented to evaluate the reliability on the automatic transmission controller. Reliability certification test can be roughly divided into two types: a quality test and life assessment test and a quality test can be subdivided into a basic performance test and environmental resistance test. There are 3 types of tests on the performance test for automatic transmission controller and environmental resistance test is composed of 14 items. Life test is performed with only the product passed this quality test. In this study, operation limit test at the high-temperatures, accelerated life test under specific temperature and accelerated life test for 2 or 3 stress levels are shown as a way for life test.

  • PDF

Solaris K4 방화벽에 대한 기능별 운영체제(32비트, 64비트)별 성능비교 연구 (A study on performance evaluation for Solaris K4 Firewall by functions and operating systems(32bit, 64bit))

  • 박대우
    • 한국통신학회논문지
    • /
    • 제28권12B호
    • /
    • pp.1091-1099
    • /
    • 2003
  • 국가정보원에서 방화벽(Firewall)의 인증을 하고 있고, 여기에서 K4 등급을 받은 방화벽이 모든 공공기관에 설치되고 있다. Solaris를 운영체제로 하는 K4 방화벽의 기능에서 패킷필터링과 NAT, 프락시 및 인증서비스 기능 등에 관해 기능 설정 전과 기능 설정 후의 성능을 비교 평가한다. 그리고 기존 32비트 체제 방화벽성능에 비해 최근 인증을 받고 있는 64비트 체제의 Solaris 방화벽을 비교 평가하여. 32비트에 비해 64비트 체제의 방화벽이 2배 이상 성능 개선이 나타남을 평가한다. 그리고, 결론에서 K4 방화벽 및 대한민국 방화벽의 연구 및 개발에 방향을 제시하여 세계에서 경쟁력 있는 시스템으로 도움이 되고자 한다.

에어챔버가 설치된 송수관로에서의 수격현상 (Waterhammer in the Transmission Pipeline with an Air Chamber)

  • 김경엽
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.177-183
    • /
    • 2002
  • The field tests on the waterhammer were carried out in the pump pipeline system with an air chamber. The effects of the input variables and the design parameters for the air chamber were investigated by both the numerical calculations and the experiments. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully studied. Among the input variables used in the waterhammer analysis, the polytropic exponent, the discharge coefficient and the wavespeed had influence on the simulated results in that order, and were calibrated in comparison with the experimental results. As the initial air volume in a vessel increased, the period of waterhammer increased and the pressure variation decreased, resulting from the reduction of the rate of pressure change in the air chamber. Using smaller orifice in the bypass pipe, the pressure rise was suppressed in some degree and the pressure surge was dissipated more rapidly as time passed. The simulations were in fairly good agreement with the measured values until 1∼2 periods of waterhammer. Not only the maximum and minimum pressures in the pipe1ine but also those occurring times were reasonably predicted. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system.

고압용기의 계장선 통과부위 밀봉기술 개발 (Development of Sealing Technology for Instrumentation Feedthrough of High Pressure Vessel)

  • 정황영;홍진태;안성호;정창용;이종민;이철용
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.137-143
    • /
    • 2011
  • Fuel Test Loop(FTL) is a facility which could conduct a fuel irradiation test at HANARO(High-flux Advanced Neutron Application Reactor). FTL simulates commercial NPP's operating conditions such as the pressure, temperature and neutron flux levels to conduct the irradiation and thermo-hydraulic tests. The In-Pile Test Section(IPS) installed in HANARO FTL is designed as a pressure vessel design conditions of $350^{\circ}C$, 17.5MPa. The instrumentation MI-cables for thermocouples, SPND and LVDT are passed through the sealing plug, which is in the pressure boundary region and is a part of instrumentation feedthrough of MI-cable. In this study, the brazing method and performance test results are introduced to the sealing plug with BNi-2 filler metal, which is selected with consideration of the compatibility for the coolant. The performance was verified through the insulation resistance test, hydrostatic test, and helium leak test.

Fast fabrication of amphibious bus with low rollover risk: Toward well-structured bus-boat using truck chassis

  • Mehrmashhadi, Javad;Mallet, Philippe;Michel, Paul;Yousefi, Amin Termeh
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.427-434
    • /
    • 2019
  • This study investigates the structural integrity of the amphibious tour bus under the rollover condition. The multi-purpose bus called Dual Mode Tour Bus (DMTB) which explores on land and water has been designed on top of a truck platform. Prior to the fabrication of new upper body and sailing equipment of DMTB, computational analysis investigates the rollover protection of the proposed structure including superstructure, wheels, and axles. The Computer-Aided Design (CAD) of the whole vehicle model is meshed and preprocessed under high performance using the Altair HyperMesh to attain the best mesh model suited for finite element analysis (FEA) on the proposed system. Meanwhile, the numerical model is analyzed by employing LS-DYNA to evaluate the superstructure strength. The numerical model includes detail information about the microstructure and considers wheels and axles as rigid bodies but excludes window glasses, seats, and interior parts. Based on the simulation analysis and proper modifications especially on the rear portion of the bus, the local stiffness significantly increased. The vehicle is rotated to the contact point on the ground based on the mathematical method presented in this study to save computational cost. The results show that the proposed method of rollover analysis is highly significant not only in bus rollover tests but in crashworthiness studies for other application. The critical impartments in our suggested dual-purpose bus accepted and passed "Economic Commission for Europe (ECE) R66".

A Study on the Change of Heavy Snow Strength by SST in Influence of Continental Polar Air Mass

  • Park, Geon-Young;Ryu, Chan-Su
    • 통합자연과학논문집
    • /
    • 제7권1호
    • /
    • pp.39-44
    • /
    • 2014
  • The results of the synoptic meteorological analysis showed that when the cold and dry continental high pressure was extended, heavy snow occurred at dawn when the upper atmosphere cooled. In particular, when the continental high pressure was extended and the upper pressure trough passed through, heavy snow occurred due to the convergence region formed in the west coast area, sometimes in the inland of the Honam area. In addition, it was verified that the changes in the humidity coefficients in the upper and lower layers are important data for the determination of the probability, start/end and intensity of heavy snow. However, when the area was influenced by the middle-latitude low pressure, the heavy snow was influenced by the wind in the lower layer (925 hPa and 850 hPa), the equivalent potential temperature, the convergence field, the moisture convergence and the topography. In Case 2010 (30 December 2010), OSTIA had the best numerical simulation with diverse atmospheric conditions, and the maximum difference in the numerically simulated snowfall between NCEP/NCAR SST and OSTIA was 20 cm. Although there was a regional difference in the snowfall according to the difference in the SST, OSTIA and RTG SST numerical tests, it was not as significant as in the previous results. A higher SST led to the numerical simulation of larger snowfall, and the difference was greatest near Buan in the west coast area.

후물재 용접부의 용착금속과 열영향부의 파괴 인성 비교 연구 (Fracture Toughness Comparison of Weld Metal and Heat-Affected Zone of Brittle Crack Arrest Steel Welding Joint)

  • 최경신;공석환;설상석;정원지
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.8-14
    • /
    • 2021
  • Even welds that have passed non-destructive testing in the case of brittle crack arrest steel materials will actually have very fine weld defects. Based on studies showing that these defects adversely affect the structure if subjected to a certain period of load, the following conclusions were obtained by conducting CTOD tests on welding joints of high-strength BCA materials, structures comprising the upper decks of a large container vessel. First of all, the fatigue pre-cracking in the weld metal and heat affected areas was tested and the behavior was identified. Both parts of the welding joint are allowable range for the class regulations. In addition, CTOD results showed that the CTOD value in the heat affected area was more than 0.5 times higher than in the weld metal area.