• Title/Summary/Keyword: Pass-by noise test

Search Result 66, Processing Time 0.022 seconds

Active Control Experiments on High-speed Elevator Vibrations (고속 엘리베이터 능동진동제어 실험)

  • Kim, Ki-Young;Kwak, Moon-K.;Baek, Kwang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.325-332
    • /
    • 2011
  • This paper is concerned with the active control experiments on elevator vibrations by means of the active roller guide. To this end, a roller guide was designed using a voice-coil actuator and linear guide. A simple proportional control algorithm combined with the band-pass filter was implemented using the DSP. Based on the initial experiments, a new control system which can handle lateral and front-back vibrations of elevator was built and tested using the elevator test tower. The experimental results show that the elevator vibrations are reduced by the active control technique.

An Experimental Study of the Cochlea-inspired Artificial Filter Bank(CAFB) for Compressed Sensing (압축센싱을 위한 달팽이관 원리기반 인공필터뱅크의 실험적 검증)

  • Heo, Gwanghee;Jeon, Joonryong;Jeon, Seunggon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.11
    • /
    • pp.787-797
    • /
    • 2015
  • In this paper, a cochlea-inspired artificial filter bank(CAFB) was developed in order to efficiently acquire dynamic response of structure, and it was also evaluated via dynamic response experiments. To sort out signals containing significant modal information from all the dynamic responses of structure, it was made to adopt a band-pass filter optimizing algorithm(BOA) and a peak-picking algorithm (PPA). Optimally designed on the basis of El-centro and Kobe earthquake signals, it was then embedded into the wireless multi-measurement system(WiMMS). In order to evaluate the performance of the developed CAFB, a vibration test was conducted using the El-centro and Kobe earthquake signals, and structural responses of a two-span bridge were obtained and analyzed simultaneously by both a wired measurement system and a CAFB-based WiMMS. The test results showed that the compressed dynamic responses acquired by the CAFB-based WiMMS matched with those of the wired system, and they included significant modal information of the two-span bridge. Therefore this study showed that the developed CAFB could be used as a new, economic, and efficient measurement device for wireless sensor networks(WSNs) based real time structural health monitoring because it could reconstruct the whole dynamic response using the compressed dynamic response with significant modal information.

Study of Flow Characteristics behind a Sunroof Wind Deflector for Wind Noise Reduction (바람소리 저감을 위한 선루프 디플렉터 주위의 유동에 관한 연구)

  • Lee, Dug-Young;Yoon, Jong-Hwan;Shin, Jae-Hyuk;Kim, Sang-Kon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.182-189
    • /
    • 2009
  • The noise from the sunroof can be divided into the low frequency buffeting noise and the high frequency turbulence noise generated when a car runs at the high driving speed. The wind deflector suppresses the buffeting noise generation by accelerating the vortex shedding from the front edge of sunroof opening, and guides the flow direction so that air can pass smoothly over the sunroof opening. To reduce the buffeting noise and the high frequency noise, it is very important to locate a deflector in a proper position depending on the driving speed and the sunroof opening width. The deflector's sectional shape also plays an important role in efficiently reducing the buffeting and high frequency noise. In this paper, we determined the optimum deflector's sectional shape and examined the flow characteristics behind a sunroof deflector through CFD analysis with changing the deflector height, the driving speed and the sunroof opening width. It is found that the deflector needs to be located in the higher location to control the buffeting noise by shedding the higher frequency vortices to accelerating vortices from the sunroof front edge. The deflector may act as a new noise source at the high driving speed, then it is desirable to put the deflector at the proper height to reduce the flow fluctuations and the noise generation. We also made a road test to verify CFD analysis results in this study.

Correlation between Proximity Noise Measurement Method (CPX) and Roadside Measurement Method (SPB) for Road Traffic Noise (도로교통소음에 대한 근접소음 측정법(CPX)과 통과소음 측정법(SPB)의 상관관계)

  • Yoo, In-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.310-319
    • /
    • 2020
  • Korea estimates the traffic noise by measuring the total traffic noise when the traffic passes (SPB; Statistical Pass-By). Another method (CPX; Close Proximity) directly measures the tire/road noise by installing a microphone near the tire. The CPX method is not a formal test method in Korea. There has been little research between CPX and SPB. This study proposes a method for estimating SPB, using the CPX, which is easy to measure. This study used the results of a large-scale test conducted by Korea Expressway Corporation (KEC) and a research paper on CPX in this section. The results by the KEC showed that the low noise pavement has a noise reduction of 10.4dB. In CPX research, the noise reduction was 10.7dB and was similar to 10.4dB in SPB. This study shows why the noise reduction is the same regardless of the position, the reason that the amount of noise reduction is similar, the difference of the noise according to the position of the microphone using the concept of noise summation and distance reduction. This study shows that including the CPX as a variable in the traffic noise prediction program is very important to improve noise prediction reliability.

Application Technique of PZT Patches to Estimation of Crack Location and Size in Structures (구조물 손상 위치 및 크기 평가를 위한 압전소자 응용기술)

  • Hong, Dong-Pyo;Hong, Yong;Wang, Gao-Ping;Han, Byeong-Hee;Hwang, Seung-Ho;Kim, Young-Moon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.315-318
    • /
    • 2007
  • Non-Destructive Health Monitoring using PZT sensors is a major concern and has great significance for research about NDT (Non-Destructive Test). In this paper, we study about the guided wave measurement method using PZT sensors to find cracks and estimate locations. Two aluminum beams bonded with PZT sensors were tested for estimating about the guided wave propagation characteristics and shape of each beam are decided in terms of analytical purpose. NI Signal Acquisition Device and specially designed LabVIEW VI program were used for data acquisition and analysis. The measured data were progressed by using a high-pass filtering.

  • PDF

An Experimental Study on the Pump Operating Characteristics with Low Flow Operation (펌프의 저 유량 운전특성에 관한 실험적 연구)

  • 오광석;신필권;박종호;심우건;조두연
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

Load Control Device for VVVF Inverter Testing (인버터 시험을 위한 부하제어 장치)

  • Kim, Gil-Dong;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.675-679
    • /
    • 2007
  • The control method of programmable dynamometer for overall test of machine is to load reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for moter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

Improved Programmable-Dynamometer Control For Traction Drive System Testing (견인구동시스템 시험을 위한 개선된 프로그램어블 다이나모메터 제어)

  • Kim G.D;Hong J.S;Shin J.R;Lee W.D;Han S.Y
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.427-432
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

Programmable-Dynamometer Control For Traction Motor Testing (전동기 시험을 위한 프로그램어블 다이나오메터 제어)

  • Kim, G.D.;Hong, J.S.;Ahn, T.K.;Lee, H.Y.;Shin, J.R.;Han, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1108-1110
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

A Study on the Improvement of the Drive-License Test Course using the Hough Transform (허프변환을 이용한 운전면허시험 코스의 개선)

  • Lee, Joon-Taik;Chung, Dong-Keun;Chung, Chang-Hwa
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • This article presents a method that improve the drive-license test system, especially the course-driving by using the image processing. Decision(pass or not) is recorded and informed to test-driver after the image processing such as image capture, grayscaling, normalization, Hough transform and decision. That result system enables us to manage much more economically and effectively.