• Title/Summary/Keyword: Partition wall

Search Result 84, Processing Time 0.026 seconds

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

A Study of Investigation the Actual conditions on Housing and Facilities for Korean Native Goat (흑염소 축사시설에 관한 실태조사 연구)

  • 최순호;정광화;조영무;강희설;김원호;김영근
    • Journal of Animal Environmental Science
    • /
    • v.7 no.1
    • /
    • pp.13-20
    • /
    • 2001
  • This study was conducted to investigate the actual conditions on housing and facilities for goat. This investigation of the actual conditions was investigated by the style of farm which was divided into sideline scale and speciality scale included 47 farms. The results are summarized as follows: Rearing scale was 48.9% for 50-100 heads per farm. Rearing type was 46.8% for grazing type and 53.2% for barn type. Housing type was 27.7% for simple frame housing and 72.3% for permanent housing. Pipe was used 80.8% with Pillar and Girder as the housing frame at farm. For the pipe used in farm, 27.7% of them was used for simple frame housing. Side wall was composed of cement and winch curtain to be 29.8%, slate roof to be 40.4%, pipe partition to be 38.3%, and cement floor to be 51.1%. Materials of feeding trough were wood and Zinc grater to be 41.5%, respectively. Type of feeding trough was square to be 70.2%. The feeding trough was located in barn to be 48.9%. Material of water supply facilities was plastic to be 87.2%. Type of water supply facilities was mostly square to be 76.6%. Water-trough was located in playground to be 48.9%. Parturition facilities were consisted of partition structure by group to be 42.5% and were mainly composed of pipe and wood. 46.8% of the barn did not have delivery room in the farm.

  • PDF

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Behaviour and design of bolted endplate joints between composite walls and steel beams

  • Li, Dongxu;Uy, Brian;Mo, Jun;Thai, Huu-Tai
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.33-47
    • /
    • 2022
  • This paper presents a finite element model for predicting the monotonic behaviour of bolted endplate joints connecting steel-concrete composite walls and steel beams. The demountable Hollo-bolts are utilised to facilitate the quick installation and dismantling for replacement and reuse. In the developed model, material and geometric nonlinearities were included. The accuracy of the developed model was assessed by comparing the numerical results with previous experimental tests on hollow/composite column-to-steel beam joints that incorporated endplates and Hollo-bolts. In particular, the Hollo-bolts were modelled with the expanded sleeves involved, and different material properties of the Hollo-bolt shank and sleeves were considered based on the information provided by the manufacture. The developed models, therefore, can be applied in the present study to simulate the wall-to-beam joints with similar structural components and characteristics. Based on the validated model, the authors herein compared the behaviour of wall-to-beam joints of two commonly utilised composite walling systems (Case 1: flat steel plates with headed studs; Case 2: lipped channel section with partition plates). Considering the ease of manufacturing, onsite erection and the pertinent costs, composite walling system with flat steel plates and conventional headed studs (Case 1) was the focus of present study. Specifically, additional headed studs were pre-welded inside the front wall plates to enhance the joint performance. On this basis, a series of parametric studies were conducted to assess the influences of five design parameters on the behaviour of bolted endplate wall-to-beam joints. The initial stiffness, plastic moment capacity, as well as the rotational capacity of the composite wall-to-beam joints based on the numerical analysis were further compared with the current design provision.

A Study on the Plane Type of House in Unified Silla Period - Focused on the Capital Remains of Silla in Gyeongju - (통일신라시대 주택의 평면유형 분석 - 경주 신라왕경 발굴유구를 중심으로 -)

  • Lee, Jeong-Mee
    • Journal of the Korean housing association
    • /
    • v.26 no.6
    • /
    • pp.139-146
    • /
    • 2015
  • In this study, the plane type of main building relics of unified Silla period house site which excavated in Gyeongju city after 1990s was classified and the architectural characteristic of them was investigated. The chronology of building relics in Silla capital city site was mostly known as 8-9th century, and by standard of column arrangement, the plane types of them could be classified as grid type, front veranda-grid type, outer column type. The outstanding characteristic of plane is wide span and open front veranda. In most relics the span were over 4 meters, and inner foundations for small post and strip foundation were found between columns. The front veranda added type buildings were composited of enclosed main room and open front veranda, and column arrangement of them dose not fall into line in most case. Thus it thought that the structures of enclosed main room and open front veranda were independent. The interior space of enclosed main room were divided two rooms by partition wall in some case. In this case, one room is enclosed by wall, and the other room has open front side. This plane is considered for the pleasant life in cold winter and hot summer.

A Study on the Commercial Streetscape Design Guideline of the Historic and Cultural Environmental Districts in Ancient Capital Gyeongju (고도(古都) 경주의 역사문화환경지구 내 상업가로경관 디자인가이드라인에 관한 연구)

  • Hyun, Taek-Soo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.1
    • /
    • pp.87-94
    • /
    • 2014
  • The objective of this study is to provide a townscape design guideline that harmonized with a historic landscape via condition investigation and landscape analysis of the cultural /commercial environment district where an improvement is a necessity. The followings are the conclusions: 1.To enhance the identity of Gyeongju, should pursue diversity in unity by making the image of architectural landscape a similar peculiarity. 2.The central commercial district where the tradition is valued and contemporary figures meet the tradition needs a landscape formation by CONTEXT. 3.Since a characteristic of the target area is a regional commercial center, to reduce its congestion, reforming the area to simple environment is required. 4.Induce buildings located on the streets with cultural properties to have Korean traditional tiled roof in order to fit in with their surroundings. 5.Make it a rule to partition a wall into tripartition, the wall surface exposed should be the same finishing materials. 6.Consider the visual aspect of pedestrians and a building's width, the recommendable height of the facade should be 3~3.6m. 7.For the design archetype of cornice, four traditional types based on Korean traditional eaves are suggested. 8.The design of signboards should break existing square-shapes, and seek a design to take advantage of icons that historicity and traditionalist of the city are expressed.

A Study on the Structure Behavior of Dry-assembled Wall with Concrete Blocks subjected to Cyclic Lateral Load (콘크리트블록으로 건식조립된 벽체의 수평반복하중에 대한 구조거동 연구)

  • Lee, Joong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.440-447
    • /
    • 2020
  • Masonry structures are used as bearing walls in small buildings, but they are generally considered non-bearing walls. They are used as partition walls that divide the interior spaces of the frame structures of buildings. In addition, wetting techniques that use mortar as an adhesive between blocks or bricks in construction are vulnerable to climatic conditions, especially cracks in mortar, which can cause conduction collapse of the walls in seismic loading. The purpose of this research was to propose a dry concrete block construction method that complements the weak axial shear stiffness and improves the weakness of the wet construction method as well as to investigate its structural behavior. In this study, the material properties of concrete blocks were examined, and the seismic performance of the proposed dry assembly structure was verified by structural behavior tests on horizontal cyclic loads. First, in these study results, concrete blocks can be applied to the dry block construction method instead of wet construction methods because they secure more than C-type blocks in KS regulations. Second, the structural performance of the wall against a horizontal cyclic load indicates that the resisting force of the assembly block wall is increased by increasing the horizontal length of the wall, forming several diagonal cracks. Finally, the proposed dry block wall structure requires a seismic performance assessment considering that the ratio of the shape of the wall by height and length is considered a major influence variable on the structural behavior under a horizontal load.

A Study on the Sound Insulation performance Survey Estimation in Apartment house (공동주택의 소음성능 실측평가에 관한 연구)

  • 함진식;박명길
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

Effects of Boundary Damping in the Prediction of Sound Insulation Performance of the Double Partition with Air-gap (중공 이중판의 차음손실 예측에 있어서 경계손실이 미치는 영향)

  • 이종화;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.873-876
    • /
    • 2002
  • It has been reported that discrepancies exist in the case of double panels with an air layer when the measured sound transmission loss is compared with the calculated values. It has been known that the cause of this discrepancy is in major from the unavoidable dips associated with the double wall resonances. In this work, several correction methods to make up for such resonances are studied. In particular, the ‘boundary damping’concept is revisited and its effects are discussed by comparing with measured values. It is shown that the correction methods are necessary for the sound insulation analysis of double partitions with an air layer, in order to ascertain the quantitative correlation between measured and predicted values.

  • PDF

A Study on the Technical Method of the Apartment Remodeling Types (공동주택 리모델링 유형별 적용 가능한 공범에 관한 연구)

  • 신교영;이정수;송용호
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.135-146
    • /
    • 2003
  • The purpose of this study is to provide the technical methods of apartment remodeling. To gather information, a survey of the technical methods of apartment remodeling in domestic and foreign was conducted. As a case study, three types will be applicable to apartment remodeling: Horizontally expanding remodeling, combining remodeling, conversion remodeling. The results of the study are as follows: 1. Horizontally expanding remodeling type will be applied the dry construction and anchor pile foundation at skeleton and the double flooring at infill. 2. Combining remodeling type will be applied the dry wall construction in order to establish or remove the partition walls. 3. Conversion remodeling type will be applied that converting building equipments and interior finish materials conversion of old to new materials.