• 제목/요약/키워드: Partition wall

검색결과 84건 처리시간 0.033초

Safety Evaluation of Fire Resistant Extruded Panel for Partition Wall System

  • Choi, Duck-Jin;Kim, Jin-Man
    • 한국건축시공학회지
    • /
    • 제12권6호
    • /
    • pp.586-595
    • /
    • 2012
  • While the extruded cement panel has many advantages compared to drywall, it has limited applicability in buildings due to its low fire resistance. However, an extruded panel in which the fire resistance has been dramatically enhanced through the addition of a-hemihydrate gypsum is expected to become widely applied as a partition wall or interior material for buildings. To ensure its applicability, certain safety requirements for use, such as the leaning load by residents, the impact by indoor articles, and the fire, need to be taken into consideration. The purpose of this study is to review the impact load resistance, horizontal load resistance, and fire resistance as required safety properties for the partition wall and interior materials of the extruded panel that includes a-hemihydrate gypsum. The results of this study show that the impact load resistance of the extruded panel that includes a-hemihydrate gypsum achieves SD grade for industrial buildings, and the horizontal impact load resistance achieves HD grade for public buildings. In addition, it provides fire-resistance for approximately 7 minutes longer than the existing extruded cement panel. Based on this result, it is confirmed the extruded panel incorporating a-hemihydrate gypsum has adequate safety properties for use as partition wall or interior material.

국내 프랜차이즈 미용실의 공간 특성에 관한 연구-세트부스를 중심으로- (A Study on the Spatial Characteristics of Franchise Beauty Salon in Korea)

  • 홍승대;이상호;신은주
    • 한국실내디자인학회논문집
    • /
    • 제22호
    • /
    • pp.16-22
    • /
    • 2000
  • The purpose of this study is to analyze characteristics of set-booth in beauty salon as well as to suggest the basic design data for franchise beauty salon. The method of this research was based on field observation of the franchise beauty salon in Seoul. The results of this research are as follows. 1) In set-booth type analysis, set-mirror wall type and set-mirror partition type are mainly used, but set-mirror table type is not showed in this research. 2) In terms of scale, wall type and partition type are classified as large scale, wall type and partition type are used as meduim scale. In shop front analysis, the result is shown in two things. If it is type, they used partition type and if it is close type, they used wall type. 3) Set-mirror is consisted of mirror and drawer and it is classified by 4 types with combination method. In a result, most of them used separated mirror type because they want to emphasize the separation between set booth and its layout. 4) Lighting method has 4 types; corniced type, bracket type, pendant type and downlight type. Among them, downlight is showed as the most-used.

  • PDF

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

소형 창문의 차음성능 측정에 관한 고찰 (Measurement of sound Insulation of small-size windows)

  • 김상렬;강현주;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.942-945
    • /
    • 2006
  • In order to measure the sound transmission loss(STL) of a test specimen such as windows, which is smaller than the test opening, a special partition is built into the test opening and the specimen is placed in that partition. This paper discusses how the measured STL is changed by the partition when a small-size window of high sound insulation is mounted. Theoretical and experimental investigations are carried out to quantify the effect of the filler wall. The results reveal that the smaller the window size is, the higher sound insulation performance of the filler wall is required in order to measure the accurate STL of the specimen. It is found that the insufficient sound insulation of the filler wall leads to the lower measured value of the window's STL.

  • PDF

다중이용업소의 소방안전기준에 관한 연구 (A Study on the Fire Protection Safety of the Public-utilization Shops)

  • 김엽래
    • 한국재난정보학회 논문집
    • /
    • 제5권2호
    • /
    • pp.10-21
    • /
    • 2009
  • This study contains the fire protection safety of the public-utilization shops. The toll of fires in the public-utilization shops is so heavy in spite the less occurency. The shops are mostly compartmented into small rooms by partition wall which hinders the evacuation of the people on fire. This study provides additional requirements on the fire safety of the public-utilization shops needed for human life and property.

  • PDF

선박용 창의 차음성능 측정용 충진벽체 설치에 관한 실험적 고찰 (Experimental discussion on the installation of filler wall for sound insulation measurements of shipboard windows)

  • 김상렬;강현주;김현실
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.276-279
    • /
    • 2008
  • In order to measure sound transmission loss (STL) of a shipboard window of small size, a special partition is built into the test opening between two reverberation rooms and the specimen is placed in that partition. For high sound insulation, the filler wall often has multi-layered structure such as double-brick wall or buckhead structure with thick steel plate, absorptive material, and sandwich panels. This paper discusses the installation method of a multi-layered filler wall that consist of gypsum boards, lead plates, and glass wool. The experimental results of various wall structures are introduced. The comparison between the results show that the sound bridge effect plays a significant role in lowering the maximum STL of the filler wall. It is also found that the higher the sound insulation performance of the filler wall is, the more important the franking transmission through other side wall of the test facility is.

  • PDF

저층 RC 건물의 내진성능 보강에 관한 실험적 연구 (An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • 한국재난정보학회 논문집
    • /
    • 제12권2호
    • /
    • pp.144-149
    • /
    • 2016
  • 현재 우리나라에서 5층 이하로 건축된 저층 철근콘크리트 건물의 대부분은 2005년 국내건축구조물의 내진설계기준이 강화되기 이전에 설계 및 시공이 이루어졌음으로, 더 이상 지진의 안전지대가 아닌 것으로 인식된 우리나라도 이들에 대한 내진성능 보강방안에 대한 연구가 필요한 실정이다. 저층 구조물의 기본 골조는 대부분 보와 기둥에 칸막이 벽으로 이루어져 있으므로 강성이 커서 지진의 횡파에 매우 취약하다. 칸막이 벽은 채광 과 환기를 위한 개구부와 그 아래 허리벽으로 구성되어 있다. 허리벽은 기둥의 강성을 증가시키지만 유효길이를 감소시켜 단주효과를 유발시키며 지진발생 시 기둥의 전단파괴를 야기할 수 있다. 그러나 현재 국내에서는 칸막이 벽에 대한 연구가 많지 않고 적합한 설계기준도 없는 실정이므로 이에 대한 연구가 필요하다고 사료된다.

빌라 사보아의 재료 패턴 및 색채 사용 연구 (A Study on the Usage of the Color and the Pattern of Materials in Villa Savoye)

  • 김소희
    • 한국실내디자인학회논문집
    • /
    • 제17권5호
    • /
    • pp.133-140
    • /
    • 2008
  • This study is purposed to understand the usage of the color and the material pattern in detail and to apply for interior architecture. Many documents have prescribed the color and the pattern at random. While the usage of the color and the materials was ignored rather than architectural form, the importance of the color and the materials stands out in modern interior space. The villa, the weekend home of the Savoye family, was built between 1928 and 1931. Particularly, the villa Savoye was focused for this study. Le Corbusier viewed case pieces for storage and wall partition for division as architecture, and he units furniture and architecture by developing partition that could be painted either the wall color to become part of the wall or in contrasting colors to stand out as wall partition. He loved white and lie believed in using it for interiors, but noted that it should also be balanced with a wall related polychromy. Color became an integral part of white structure of the villa savoye that was raised on stilt with an exterior wall at the base painted green as a visual connection with the lawn. Color was used architecturally in the interior as well, with white walls interrupted by planes of pink, blue and red ocher and it gives the space an unexpected playfulness with tile color of the finishing materials. the various usage of the color and material patterns constitute an element of great architectural richness. They have a unique principle based on emotional order and make the man move to another space and experience the spacial connection.

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

개별공간의 자외선 살균 시스템 (UV Immune System of Personalized Space)

  • 정기범;최상곤
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.