• Title/Summary/Keyword: Particulates

Search Result 335, Processing Time 0.024 seconds

Pollution of Pb in paddy field soil and rice plants at roadside areas;I. Pollution of Pb in paddy field soil and its chemical forms (도로변(道路邊)에 인접(隣接)한 경작지(耕作地) 토양(土壤) 및 작물체중(作物體重)의 연오염(鉛汚染) 제(第)1보(報) 경작지(耕作地) 토양중(土壤中)의 연오염(鉛汚染) 및 화학적(化學的) 형태(形態))

  • Lee, Seog-June;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 1991
  • The object of this stduy was to investigate the pollution of Pb in paddy field soil with different distance from roadside and to find out the relationship between the ratio of chemical fractions of total Pb and soil characteristics. Lead from automobiles is exhausted as particulates composed primarily of halide compounds (PbBrCl, $PbBr_2$, $PbCl_2$). The samples of soil were collected directly from the paddy fields with different distance from the roadside of highway and expressway which are located in Kyungpook province. A sequential extraction procedure was used to fractionate Pb in paddy field soil into the disignated forms of water soluable, exchangeable, organically bounded, carbonate, sulfide, and residual Pb. Results obtained are summerized as follows. 1. The content of Pb in paddy field soil was the highest in Chungdo, 30.0 ppm, the lowest in Koryung, 14.8 ppm, and the total average content was 21.9 ppm. The effect of traffic volume was not clear, but a slight difference according to the order of opened year of roads was showed. 2. The effect of distance from roadside was not clear. The content of Pb in paddy field soil with different distance from roadside was 22.2 ppm within l0m, 22.1 ppm in 10∼30m, 22.2 ppm in 30∼50m. and 21.3 ppm beyond 50m. 3. The distribution of Pb fractions in soil showed a wide difference depending on soil properties. The average content of exchangeable. organically bounded, carbonate, sulfide, and residual Pb was 8.6%, 33.6%, 29.8%, 21.5%, and 6.7%, of total Pb in the soil, respectively. 4. The content of organically bounded Pb in soil showed highly positive correlation with organic matter and CEC, while the content of exchangeable Pb was highly negative correlation. 5. With higher soil organic matter and CEC, organically bounded Pb fraction tend to be higher but exchangeable Pb fraction tend to be lower. Other forms of Pb showed no difference with soil organic matter contend and CEC. The distribution of Pb fraction related to CEC showed similiar tendency with that of organic matter content.

  • PDF

Characterization of Low-Temperature Pyrolysis and Separation of Cr, Cu and As Compounds of CCA-treated Wood (CCA (Chromated Copper Arsenate) 처리 목재의 저온 열분해와 CCA 유효 성분분리 특성)

  • Lim, Kie-Pyo;Lee, Jong-Tak;Bum, Jung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • This study was carried out to separate the heavy toxic metals in eco-building materials by low-temperature pyrolysis, especially arsenic (As) compounds in CCA wood preservative as a solid in char. The pyrolysis was carried out to heat the CCA-treated Hemlock at $280^{\circ}C$, $300^{\circ}C$, $320^{\circ}C$, and $340^{\circ}C$ for 60 mins. Laboratory scale pyrolyzer composed of [preheater$\rightarrow$pyrolyzer$\rightarrow$1st water scrubber$\rightarrow$2nd bubbling flask with 1% $HNO_3$ solution$\rightarrow$vent], and was operated to absorb the volatile metal compound particulates at the primary water scrubber and the secondary nitric acid bubbling flask with cooling condenser of $4^{\circ}C$ under nitrogen stream of 20 mL/min flow rate. And the contents of copper, chromium and arsenic compounds in its pyrolysis such as carbonized CCA treated wood, 1st washing and 2nd washing liquors as well as its raw materials, were determined using ICP-AES. The results are as follows : 1. The yield of char in low-temperature pyrolysis reached about 50 percentage similar to the result of common pyrolytic process. 2. The higher the pyrolytic temperature was, the more the volatiles of CCA, and in particular, the arsenic compounds were to be further more volatile above $320^{\circ}C$, even though the more repetitive and sequential monitorings were necessary. 3. More than 85 percentage of CCA in CCA-treated wood was left in char in such low-temperature pyrolytic condition at $300^{\circ}C$. 4. Washing system for absorption of volatile CCA in this experiment required much more contacting time between volatile gases and water to prevent the loss of CCA compounds, especially the loss of arsenic compound. 5. Therefore, more complete recovery of CCA components in CCA-treated wood required the lower temperature than $320^{\circ}C$, and the longer contacting time of volatile gases and water needed the special washing and recovery system to separate the toxic and volatile arsenic compounds in vent gases.

Analysis of the Phosphate Movement Using the Mesocosm in the Wetland (Mesocosm을 이용한 습지에서의 인 거동 분석)

  • Son, Jang-Won;Yoon, Chun-G.;Kim, Hyung-Chul;Haam, Jong-Hwa
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • This study used a mesocosm which presumes movement of the nutrient (especially $PO_{4^-}P$) in the wetland. After setting up the mesocosm inside the wetland and adding the $PO_{4^-}P$, observed the movement of the $PO_{4^-}P$ every hour. We analyzed the variables which had the possibility of affecting $PO_{4^-}P$ concentration in the wetland-flora, absorbing rate of algae, settling rate, release rate. Immediately after adding $PO_{4^-}P$, the concentration of the TP in water column at each mesocosm was 0.48, 12.4, 20.4, $23.6\;mg\;L^{-1}$, after 21 days they were 0.6, 1.92, 6.97 and $6.94\;mg\;L^{-1}$ respectively. The concentration of the TP in water column at the mesocosm decreased on average 73.7%. The concentration of the $PO_{4^-}P$ inside reed, algae and sediment in the mesocosm was increased from $0.73mg\;gDW^{-1}$, $3.81mg\;gDW^{-1}$, $466.1mg\;kg^{-1}$ to $0.83mg\;gDW^{-1}$, $4.57mg\;gDW^{-1}$ and $813.3mg\;kg^{-1}$ respectively. Algae is more sensitive than reeds in absorption of the nutrient. TP removal by settling was highest. Budgeting of TP indicated that P moved from particulates in the water column to sediment and algae. Immediately after adding $PO_{4^-}P$, water column (24.2%) and sediment (49.0%) dominated TP storage, with algae (10.3%) and reed (16.4%) holding smaller proportions of TP. After 21 days, Sediment (59.0%) and algae (17.9%) dominated TP storage, with water column (7.1%) and reed (15.8%) holding smaller proportions of TP. Estimation of phosphate movement using mesocosms is an appropriate method because wetlands have many controlling factors. Analysed data can be compared to background data for wetland construction and management.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.