• Title/Summary/Keyword: Particulate filtration

Search Result 110, Processing Time 0.029 seconds

Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion (그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구)

  • Cho, Kyungil;Kang, Giwon;Shin, Jiyoon;Kim, Changhyuk
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection

  • Lee, Ji Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.4
    • /
    • pp.234-240
    • /
    • 2016
  • Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

Separation and Extraction of Hot Particulate from contaminated Perfluorocarbon solution

  • Kim Gye-Nam;Narayan Mathuresh;Wou Hui-Jun;Jung Chong-Hun;Oh Won-Zin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.70-71
    • /
    • 2005
  • It was an idea to develop a system to remove the contaminated hot particulate to make clean nuclear research facilities to the clear visibility for researcher. In order to clean micron and sub micron size particulates from used PFC solution as a decontamination tool. Since PFC solution is very expensive so it was a high recommendation to develop the some filtration equipment to purify PFC for next decontamination process, in additionally, reduce the secondary waste. However, we developed an easy and economic filter system to purify the PFC solution. The major advantage of the process operates in closed loop under near ambient conditions, thus minimizing the potential for fugitive TRU emissions and reduces the secondary waste. This has very significant safety and cost impacts. Here we proposed the two types PFC filter systems.

  • PDF

Effect of inlet structure of filtration system on the removal characteristics of iron particles by ceramic candle filters (집진장치의 유입구조에 따른 세라믹필터의 철입자 제거특성에 미치는 영향)

  • Park, Young-Ok;Jeong, Ju-Yeong;Seo, Yong-Chil
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.189-197
    • /
    • 2009
  • Wet-type particulate removal system is employed in most of ironmaking processes. These de-dusting systems require additional downstream aggregates for treatment of water and for drying of the collected slurry. Thus dried slurry can be pressed in shape of briquettes and recycled in the steelmaking process. Different from the wet-type, the dry-type particulate removal systems generate no slurry. A high-temperature, high-pressure de-dusting system with inertial inlet was developed. The target application of this system was to remove particulate matter generated from the novel ironmaking process and other steelmaking processes. In this study we conducted tests with this newly developed system to evaluate the performance of the silica-carbide (SiC) ceramic filters. In addition, for purpose of comparison, we also conducted tests with a unit which has conventional direct inlet. Fe-Particles collected from the novel ironmaking process were used in our tests as test dusts. The temperature and the pressure were kept constant at their respective values $800^{\circ}C$ and $3kg_f/cm^2$.

  • PDF

A periodic case study of diesel vehicle drivers exposed to diesel particulate matter in an underground coal mine

  • Lee, Sugil;Jankewicz, Ganyk;Kim, Jung-Hee;Chung, Kwang Bo
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.265-270
    • /
    • 2018
  • This study was to measure the exposure of diesel vehicle drivers to elemental carbon (EC) as an indicator of diesel particulate matter (DPM) emitted from diesel vehicles in an underground coal mine over 3 years as per NIOSH Method 5040. Our study results (range $10{\mu}g/m^3-377{\mu}g/m^3$ for the loader drivers, $19{\mu}g/m^3-162{\mu}g/m^3$ for the SMV drivers) were similar or less than previous study results (range $5{\mu}g/m^3-2,200{\mu}g/m^3$) for normal mine operations. From this study results, it appeared that the exposures decreased in the second and the third year. It is thought that the reasons for the decreased personal DPM (EC) exposures over the 3 years were related to the following recommendations; more frequent monitoring and maintenance of the diesel vehicles and their DPM filtration systems, more consistent monitoring of the mine's ventilation system and changes of work practices such as minimizing the opening of diesel vehicle windows. An educational program on adverse health effects of exposure to DPM and use of respiratory protection (P2 respirators) also assisted in minimizing driver exposure to DPM.

Flow Analysis of Yellow Dust Multi-Layer Mask for Maximization of Filtration Area (여과면적이 극대화된 황사용 주름마스크의 유동해석)

  • Jang, Sung-Cheol;Kim, Han-Joo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.4
    • /
    • pp.339-343
    • /
    • 2017
  • Masks are a portable functional product for daily use. They can protect user health by filtering harmful fine particles in the air. In the past decade, there have been approximately 10 yellow dust incidences per year, amounting to a total duration of 20 days, and they continue to increase year after year. In addition, the frequency of yellow dust incidences in Korea has increased by more than four times compared to levels from the 1970s. Statistical reports indicate that annual damages caused by yellow dust amount to more than six trillion KRW. This study developed a zero-fog multi-layer mask with a collection efficiency and yellow dust and particulate matter filtration areas that are at least thrice as effective as existing masks. The new mask also reduces pressure drag by half.

The Filtrational Characteristics of Magnetic Fibrous Polymeric Filter as an Oil Filter for Automotive (자동차용 자성폴리머 오일필터의 여과특성 연구)

  • 안병길;최웅수;권오관;문탁진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.179-186
    • /
    • 1996
  • The magnetic fibrous polymeric oil filter for automotive was obtained by pneumoextrusion processing prepared from thermoplastic polymer(polyamide) containing magnetic particulate filer (Ba ferrite), and treated subsequently in a magnetic fields. Using an oil filter tester and particle quantifier, the dependence of filtrational characteristics of the magnetic oil filter on the parameters of mean pore sizes and magnetic properties were analyzed. Also experimental engine-bed test of oil filters was investigated. The magnetic fibrous polymeric filter was shown to possess a highly filtration efficiency in filtering the fine metal particles with increasing the magnetic force of filter element. In this study, we knew that efficiency of magnetic fibrous polymeric filter was dependent on the magnetic strength of the filter elements.

  • PDF

Processing Methods for the Preparation of Porous Ceramics

  • Ahmad, Rizwan;Ha, Jang-Hoon;Song, In-Hyuck
    • Journal of Powder Materials
    • /
    • v.21 no.5
    • /
    • pp.389-398
    • /
    • 2014
  • Macroporous ceramics with tailored pore size and shape could be used for well-established and emerging applications, such as molten metal filtration, biomaterial, catalysis, thermal insulation, hot gas filtration and diesel particulate filters. In these applications, unique properties of porous materials were required which could be achieved through the incorporation of macro-pores into ceramics. In this article, we reviewed the main processing techniques which can be used for the fabrication of macroporous ceramics with tailored microstructure. Partial sintering, replica templates, sacrificial fugutives, and direct foaming techniques was described here and compared in terms of microstructures and mechanical properties that could be achieved. The main focus was given to the direct foaming technique which was simple and versatile approach that allowed the fabrication of macro-porous ceramics with tailored features and properties.

A Study on Development of the Wet Type Filter for Combustion Air of Diesel Engine (디젤엔진 연소공기 습식여과기의 개발에 관한 연구)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.158-164
    • /
    • 2008
  • In this paper, the performance of wet type filter for diesel engine combustion air has been studied with effects of air temperature, humidity, and pressure. After experiments are performed without diesel engine, it has been investigated the applicability to diesel engine. Wet type filter for diesel engine combustion air had advantages that it is not necessary to change air filter and that engine exhaust gas is environmentally friendly due to low NOx and particulate emission. Also, the filtration performance has been carried out with smoke shell.

Filtration Characteristics of Metal Foam Filters for DPF Combined with Electrostatic Precipitation Mechanism (전기집진 기제를 조합시킨 DPF용 금속 폼 필터의 여과 특성)

  • Park, Seok-Joo;Lee, Dong-Geun;Kim, Jin-Hyun;Cho, Gyu-Baek;Kim, Hong-Suk;Jeong, Young-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • Filtration studies, using simulated test nanoparticles or diesel nanoparticles, have been performed about Inconel foam filters for DPF combined with electrostatic precipitation. The simulated test particles were synthesized by laser ablation in the nitrogen atmosphere at the standard condition. The diesel particles were exhausted from the diesel engine driven on the condition of idle or load mode. Filtration efficiency of the metal foam filter is very low because most of particles are penetrated through the large pores of filter. However, the efficiency was considerably improved by applying the electric field to the filter and/or charging the nanoparticles. Nevertheless, the pressure drop of filter hardly increased because the filter-pores were not clogged by deposited particles and kept open.