• 제목/요약/키워드: Particulate filter

검색결과 381건 처리시간 0.023초

공동주택 전열교환기 필터종류 및 두께에 따른 미세먼지 제거율 평가 (Evaluation of Particulate Matter Removal Rate according to Filter Type and Thickness of Total Heat Exchanger in Apartment Houses)

  • 송용우
    • 토지주택연구
    • /
    • 제11권4호
    • /
    • pp.93-98
    • /
    • 2020
  • This study examined the particulate removal performance of three different types of air filters inside a heat exchanger. Of interest was the ability of each filter type in reducing the transmission of outdoor particulate matter of PM10 from entering an apartment while the heat exchanger was in operation. The study tested one commonly used medium filter (E11 grade) and two HEPA filters (H13 grade) of different thicknesses. Two different concentrations of particulate matter were used in the experiment to address different ambient air quality conditions in Korea, 32.75 ㎍/㎥ and 67.26 ㎍/㎥. Study results indicated that under the particulate matter concentration of 32.75 ㎍/㎥, all three filters were capable of removing more than 95% of the fine dust. However at a particulate matter concentration of 67.26 ㎍/㎥, the medium E11 grade filter was only able to remove about 90% of the particulates whereas the HEPA H13 grade filters were able to remove 95% or more of the particulates. The thicker HEPA filter (40T) was also more effective in removing particulates than the thinner HEPA filter (20T) by about 1.6 to 3 percentage points. Based on the findings of this study, it is recommended that HEPA filters of 20T thickness or greater be used during the high air pollution seasons of winter and spring in Korea while medium filters can be used during the other seasons to reduce outdoor air pollution transmission indoors.

DPF내 포집된 입자상 물질의 산화율 산출을 위한 실험적 연구 (Experimental Study on Estimation of Oxidation Rate of PM inside of Diesel Particulate Filter)

  • 심범주;박경석;조규희;이형준;민병두
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.98-103
    • /
    • 2013
  • Conventional method to estimate mass of particulate matter accumulated in diesel particulate filter is to use pressure difference between upstream and downstream of the filter. Then measured pressure difference should be compared that of clean condition which is no particulate matter accumulated in DPF. During regeneration soot oxidation is also estimated by same method. This methodology, however, has demerit on accuracy because of pressure difference deviation of clean DPFs and pressure difference caused by non-carbon based PM which is different from that of caused by carbon based PM. This study suggests new methodology to estimate accumulated soot oxidation rate through exhaust gas characteristics during regeneration. Results, more high accuracy of soot oxidation was obtained by analysis of relationship between fuel mass and concentration of carbon dioxide and oxygen.

디젤기관의 성능과 배기관 특성에 의한 필터트랩의 열재생에 관한 실험적 연구 (An Experimental Study on Thermal Regeneration of Filter Trap by Diesel Engine Performance and Characteristics of Exhaust Pipe)

  • 오용석
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.50-55
    • /
    • 1999
  • The exhaust emissions from diesel vehicle are known to be harmful to human health and environment. Recently, one of the most environment problems is particulate matter. In this study, through the actual exper iment and heat transfer of exhaust pipe in light duty diesel engine equipped with the ceramic filter trap of throttling type, following results are obtained. 1. In case of light duty diesel engine equipped with ceramic filter trap of throttling type, Power and torque of engine were decreased about 5%, compared with the case without trap system. It means that was not so much effect on base engine performance.2. If the length of exhaust pipe when equipping with ceramic filter trap is suitably controlled, the range of regeneration will be expand much more.3. Particulate matter reduction efficiency of ceramic filter trap system was about 70%-80%, so it was proved a good system to reduce particulate matter.In experiment, test was conducted to estimate engine emission in 2,476cc light duty diesel engine which was equipped with ceramic filter trap.

  • PDF

금속 DPF를 이용한 입자상물질의 저감효율에 관한 연구 (PM Reduction Efficiency using Metal Type DPF)

  • 나완용
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.176-180
    • /
    • 2013
  • After-treatment apparatus ceramic DPF (diesel particulate filter) have been applied to reduce harmful particulate matters(PM) among emissions from diesel engines so far, but they are easy to be fragile and weak in thermal shock. This research aims to investigate a metal type filter which is superior in mechanical strength and heat conduction rate and is beneficial economically in manufacturing. Basic performance of metal DPF such asloading test, temperature gradient test, thermal shock test, heat resistant test and back pressure was carried out. And then their experimental data provided key informations in designing and manufacturing such as detailed structures of metal mesh filter. Also diesel engine and vehicle of 2957cc displacement was tested under lug-down 3 mode and CVS-75 mode. PM reduction efficiency was 54.5% using metal DPF without loss of performance and fuel consumption.

희석터널을 사용한 디젤엔진 미립자상 배출물 측정에 관한 연구 (An experimental study on measurement of diesel particulate emission using dilution tunnels)

  • 채재우;김희수;오신규
    • 오토저널
    • /
    • 제9권1호
    • /
    • pp.40-48
    • /
    • 1987
  • A Mini-Dilution Tunnel is described as a scaled down comparision of a Standard Tunnel. The paper presents the result of experimental investigations on measuring the particulate emission of a diesel engine in a Mini and a Standard Dilution Tunnel. The result offers a contribution to understanding about the influence of several parameters including dilution ratios, mixture temperatures, mixture conditions, filter temperatures, and flow conditions. In the experiment either increasing the filter temperature and mixture temperature at a fixed dilution ratio or increasing the dilution ratio at a fixed filter temperature and mixture temperature resulted in a decrease in the total particulate mass. These changes in total particulate mass were attributed to the changes in the soluble organic fraction of the particulate sample. Also, mass differences between the Mini and the Standard Dilution Tunnel for the same engine conditions were within approximately 15% of each other.

  • PDF

환경 대기중 Nitrate의 생성에 관한 연구 (A Study on the Formation of Nitrate in the Atmosphere)

  • 천만영;강공언;김희강
    • 한국대기환경학회지
    • /
    • 제8권1호
    • /
    • pp.68-73
    • /
    • 1992
  • A study on the formation of particulate nitrate$(NO_3^-)$ and gaseous nitrate$(HNO_3)$ in the atmosphere was carried out in Seoul from Oct 8 to 11 1991. To collect $NO_3^-$ and $HNO_3$ in the ambient air, dual filter pack sampler (47mm$\phi$) was used. In the dual filter pack sampler, the first filter was Teflon filter (poresize 1$\mum$) for collection of $NO_3^-$ and the second filter was Nylon filter (poresize 0.45 $\mum$) for $HNO_3$. Particulate nitrate$(NO_3^-)$ and Sulfate ions were analysed by Ion chromatography. $HNO_3$ concentration was higher in the day time $(9.93\mug/m^3)$ than the night time$(3.50\mug/m^3)$, and Particulate nitrate$(NO_3^-)$ concentration was higher in the night time and early morning$(6.21\mug/m^3)$ than the day time$(4.31\mug/m^3)$. The conversion rate of $NO_x$ to total nitrate$(NO_3^-, HNO_3)$ was 7.57%/hr in the day time and 4.79%/hr in the night time, and total average conversion rate was 5.60%/hr.

  • PDF

석탄화력발전시설에서의 하이브리드 집진기 적용 시 수은화합물 제어성능 평가 (Performance of Removal Efficiency for Mercury Compounds using Hybrid Filter System in a Coal-fired Power Plant)

  • 성진호;장하나;백승기;정법묵;서용칠;강연석;이철규
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.261-269
    • /
    • 2014
  • This study focused on the performance of the newly developed hybrid filter system to capture fine particulate matter and mercury compounds in a coal-fired power plant. The hybrid filter system combining bag-filter and electrostatic precipitator had been developed to remove fine particulate matter. However, it would have a good performance to control mercury compounds as well. In Hybrid filter capture system, the total removal efficiency of total mercury compounds consisting of particulate mercury ($Hg_p$), oxidized mercury ($Hg^{2+}$), and elemental mercury ($Hg^0$) was 66.2%. The speciation of mercury compounds at inlet and outlet of Hybrid filter capture system were 1.3% and 0% of $Hg_p$, 85.2% and 68.1% of $Hg^0$, and 13.5% and 31.9% of $Hg^{2+}$, respectively. In hybrid filter capture system injected with 100% of flue-gas, the removal efficiency of total mercury was calculated to increase to 93.5%.

미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구 (A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.

연속재생 DPF의 재생 성능에 미치는 차량 운행패턴의 영향 (Influence of Driving Pattern on Regeneration Performance of Continuously Regenerating Diesel Particulate Filter)

  • 황진우;이창식
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.358-364
    • /
    • 2009
  • This paper is to investigate the influence of driving patterns of slow and high speed vehicles on the performance of continuously regenerating diesel particulate filter(DPF) system matched with operating conditions in field application. The DPF performance test for field application was carried out for two identical DPFs installed to slow and high speed vehicles. A slow speed vehicle was selected among local buses which have driving patterns to repeat running and stop frequently, while a high speed vehicle was prepared to have long route of high speed over 60km/h like inter-city buses. In this test, the regeneration performance on the DPF of slow speed vehicle deteriorated because of high soot load index(SLI) in spite of same balance point temperature(BPT) distribution for high speed vehicle. The DPF of slow speed vehicle melted in the end because the rapid increase of back pressure caused high temperature over $1200^{\circ}C$ in the ceramic wall of DPF. The PM components like ash collected to the filter in the DPF were analyzed in order to investigate the cause of the defect and provide an operation performance of DPF system. In the result of the analysis, high levels of lubrication oil ash(Ca, Mg, P, Zn) were detected.

금속폼을 이용한 Partial DPF의 설계 및 전산유체해석 연구 (Study of Design & CFD Analysis for Partial DPF Utilizing Metal Foam)

  • 윤천석;조규백
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.24-34
    • /
    • 2009
  • DPF(Diesel Particulate Filter)s have been used to reduce the most of PM(particulate matters) from the exhaust emissions of diesel engine vehicles. Metal foam is one of promising materials for the DPFs due to its cost effectiveness, good thermal conductivity and high mechanical strength. It can be fabricated with various pore sizes and struct thickness and coated with catalytic wash-coats with low cost. In order to design metal foam filter and analyze the flow phenomena, pressure drop and filtration experiment are carried out. Partial DPF which has PM reduction efficiency of more than 50 % is designed in this paper. Also, CFD analysis are performed for different configurations of clean filters in terms of pressure drop, uniformity index, and velocity magnitude at face of filter. Filter thickness and the gap between front and rear filters are optimized and recommended for manufacturing purpose.