• 제목/요약/키워드: Particulate exposure concentration

검색결과 95건 처리시간 0.025초

사업장 내 사무실의 $PM_{2.5}$ 노출 평가 (Exposure Assessment of $PM_{2.5}$ in Manufacturing Industry Office Buildings)

  • 남미란;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제23권4호
    • /
    • pp.356-366
    • /
    • 2013
  • Objectives: This study was conducted in order to evaluate $PM_{2.5}$ concentrations at 20 offices connected to the manufacturing industry from the beginning of September to the end of November 2012. Methods: A total of 20 samples were collected from 20 office buildings. Each $PM_{2.5}$ sample was collected by a 37 mm PTFE filter attached to a Personal Environment Monitor. Results: The geometric mean concentrations of $PM_{2.5}$ in the offices was $23.47{\mu}g/m^3$, and the mean $PM_{2.5}$ concentrations measured in smoking offices were much higher than those of measured in non-smoking offices($24.83{\mu}g/m^3$ and $21.55{\mu}g/m^3$, respectively). $PM_{2.5}$ was revealed to be higher in small offices($39.52{\mu}g/m^3$) than in medium or large offices($22.69{\mu}g/m^3$ and $11.04{\mu}g/m^3$, respectively). The mean $PM_{2.5}$ concentration of offices located on the 1st floor was higher than that of those on the 2nd floor, and those of offices located in the workplace were higher than those out of the workplace. The multiple regression model showed that concentration of $PM_{2.5}$ was positively associated with the method of ventilation. Conclusions: Smoking, ventilation method, location, and inflow of outdoor particulate matter are the most important factors for office $PM_{2.5}$ concentrations.

Spatial Heterogeneity and Long-term Changes in Bivalve Anadara broughtoni Population: Influence of River Run-off and Fishery

  • Silina, Alla V.
    • Ocean Science Journal
    • /
    • 제41권4호
    • /
    • pp.211-219
    • /
    • 2006
  • A comparison was made of population of the economically important cockle Anadara (=Scapharca) broughtoni (Bivalvia, Arcidae) inhabiting different areas of the Razdolnaya River estuary at the head of Amurskii Bay (Peter the Great Gulf, East Sea). Also, changes in cockle population density and structure, as well as in cockle growth rates during the last 20 years were studied. In all years of investigation, the morphometrical parameters and growth rates of cockles were smaller at the sites located close to the River mouth than farther down-estuary. The differences can be attributed to higher concentration of suspended particulate matter, decreased salinity and water temperature, as well as a longer exposure to these unfavorable environmental factors at sites located close to the River mouth, compared to farther sites. For two decades, cockle population density had decreased by almost 30 times at some sites in the River estuary. The main reason for this population decline is commercial over-fishing of the cockle. Besides, for the last 20 years, linear parameters of the cockles in the population decreased approximately by 30% and weight parameters, almost two times. Cockle growth rates also decreased for this period. Evidently, these facts are due to the damaging effect of dredging.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • 한국환경과학회지
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

서울지역 미세먼지가 호흡기계 질환으로 입원한 환자에 미치는 영향 (The Effects of PM10 on the Hospital Admission of Patients with Respiratory Disease in Seoul, Korea)

  • 박해용;박윤숙
    • 융합정보논문지
    • /
    • 제9권6호
    • /
    • pp.194-201
    • /
    • 2019
  • 서울지역의 호흡기질환으로 입원한 환자를 대상으로 미세먼지 노출에 대한 건강영향을 평가하였다. 건강보험공단의 2002-2010년 동안 표본코호트의 만성폐쇄성 폐 질환(COPD), 천식 및 폐렴과 같은 호흡기 질환으로 입원한 13,974명의 환자를 대상자로 하였다. 추적관찰 기간동안 미세먼지 농도가 50ug/m3 이상에서 10ug/m3 증가할 때 15세 미만의 연령층에서는 1.38%, 65세 이상의 연령층에서는 1.62%, 75세 이상 연령층에서는 2.87% 호흡기질환으로 입원이 증가하였고, 폐렴환자는 1.50%, COPD 환자는 1.51%, 폐렴 및 천식환자는 1.55% 입원이 증가하였다. 또한 미세먼지가 80ug/m3 이상에서는 65세 이상 연령층에서 3.71%, 75세 이상 연령층에서 4.25% 입원환자가 증가하였다. 높은 미세먼지농도와 호흡기 질환으로 입원한 환자들과, 특히 노인에서 관련성이 높게 나타났다. 이미 호흡기 질환이 있었던 사람들, 특히 나이가 많은 환자는 고농도의 미세먼지에 노출되지 않도록 주의해야 한다.

부산시 항만 및 산단 인근 주거지역 대기질 모니터링과 분기별 특성확인 (Air Quality Monitoring in Residential Areas near Ports and Industrial Complexes in Busan)

  • 주현지;이승호;김민정;이가빈;홍영습
    • 한국환경보건학회지
    • /
    • 제50권3호
    • /
    • pp.181-190
    • /
    • 2024
  • Background: Air pollutants have been reported to have harmful effects on human health. Busan is a vulnerable area in terms of air quality due to the installation of various industrial complexes, particularly the port industry. However there is limited research data on the ambient air quality of residential areas near ports and industrial complexes. Objectives: This study aimed to determine the quarterly levels of air pollutants near industrial complexes and ports and to identify trends and characteristics of air pollutant exceedances. Methods: Air measurements were conducted quarterly. The measured air pollutants included O3, SO2, CO, NO2, PM10, and PM2.5. PM10 and PM2.5 were measured using BAM-1020 equipment, while O3, SO2, CO, and NO2 were measured using AP-370 Series equipment. The quarterly concentration levels of air pollutants were determined, and the influence of precipitation and commuting hours on fine particulate matter was examined. Analysis of variance (ANOVA) was conducted to determine if there was significance between the concentrations of fine particulate matter during commuting hours and non-commuting hours. Results: The concentrations of air pollutants were generally higher in the first and second quarters. Furthermore, the concentrations of PM10 and PM2.5 tended to decrease continuously following consecutive rainfall, with concentrations at the end of rainfall periods lower than those observed at the beginning. The frequency of exceeding average concentrations of PM10 and PM2.5 was higher on weekdays. Moreover, the average concentrations of PM10 and PM2.5 during weekday commuting hours were higher compared to non-commuting hours. Conclusions: The concentrations of air pollutants in the survey area were found to be higher than the overall average in Busan. Based on this study, continuous air quality monitoring is necessary for residential areas near industrial complexes and ports. For further research, health biomonitoring of residents in these areas should be conducted to assess their exposure levels.

대구 안심연료단지 환경오염물질 노출 평가(III) - 원소 탄소, 결정형 실리카 및 안정동위원소비를 이용한 오염원 기여율 및 분포특성 - (Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(III) - Contribution and distribution characteristics of air pollutants according to elemental carbon, crystalline silica, and stable isotope ratio -)

  • 정종현;피영규;손병현;배혜정;양원호;김지영;김근배;최종우;박성준;이관;임현술
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.392-404
    • /
    • 2015
  • Objectives: This study measured and analyzed the concentrations of crystalline silica, elemental carbon and the contribution ratio of pollutants which influence environmental and respiratory disease around the Ansim Briquette Fuel Complex in Daegu, Korea. Methods: We analyzed the crystalline silica and elemental carbon in the air according to FTIR(Fourier Transform Infrared Spectroscopy) and NIOSH(National Institute of Occupation Safety and Health) method 5040, respectively. In addition, lead stable isotopes, and carbon and nitrogen stable isotopes were analyzed using MC-ICP/MS(Multi Collector-Inductively Coupled Plasma/Mass Spectrometer), and IRMS(Isotope Ratio Mass Spectrometer), respectively. Results: The concentration of crystalline silica in the direct exposure area around the Ansim Briquette Fuel Complex was found to be $0.0014{\pm}0.0005mg/Sm^3$, but not to exceed the exposure standards of the ACGIH(American Conference of Governmental Industrial Hygienists). In the case of the autumn, the direct exposure area was found to show a level 2.5 times higher than the reference area, and on the whole, the direct exposure area was found to have a level 1.4 times higher than the reference area. The concentration of elemental carbon in the direct exposure area and in the reference area were found to be $0.0014{\pm}0.0006mg/Sm^3$, and $0.0006{\pm}0.0003mg/Sm^3$, respectively. This study confirmed the contribution ratio of coal raw materials to residentially deposited dusts in the area within 500 meters from the Ansim Briquette Fuel Complex and the surrounding area with a stable isotope ratio of 24.0%(0.7-62.7%) on average in the case of carbon and nitrogen, and 33.9%(26.6-54.1%) on average in the case of lead stable isotopes. Conclusions: This study was able to confirm correlations with coal raw materials used by the Ansim Briquette Fuel Complex and the surrounding area. The concentration of some pollutants, crystalline silica, and elemental carbon emitted to the direct-influence area around the Ansim Briquette Fuel Complex were relatively higher than in the reference area. Therefore, we need to impose continuous and substantive reduction countermeasures in the future to prevent particulate matter and coal raw materials in the study area. It is time for the local government and authorities to prepare active administrative methods such as the relocation of Ansim Briquette Fuel Complex.

서울지역 교통수단별 이동시간과 호흡량을 고려한 미세먼지 흡입량 추정에 관한 연구 (Estimation of PM10 and PM2.5 inhalation dose by travel time and respiratory volume in common transport microenvironments in Seoul, Korea)

  • 이용일;정원석;황도연;김태성;박덕신
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.97-105
    • /
    • 2018
  • Recently, people's interest in particulate matter (PM) has been increasing, due to its hazardous health effects. The purpose of this study was to investigate the concentrations and as well as the inhaled weight of PM, correlated with person's heart rate in subway, bus, vehicle and bicycle in the major public transportation (Sadang - Jamsil and Nowon - Dongdaemun) in Seoul. The concentration of $PM_{10}$ and $PM_{2.5}$ were measured from each of transportation means and calculated the average concentrations which were 87.2 and $57.8{\mu}g/m^3$ for subway, 62.8 and $42.5{\mu}g/m^3$ for vehicle, 61.5 and $36.8{\mu}g/m^3$ for bus and 53.0 and $29.4{\mu}g/m^3$ for bicycle in $PM_{10}$ and $PM_{2.5}$ respectively. Inhalation dose for $PM_{10}$ and $PM_{2.5}$ were estimated at 248.1 and $139.4{\mu}g$ for bicycle, 56.7 and $39.3{\mu}g$ for vehicle, 49.4 and $29.9{\mu}g$ for bus and 44.3 and $29.1{\mu}g$ for subway, respectively. Even though subway had the highest concentration, the highest inhalation dose was the bicycle. It was due to the long travel time-exposure and breathing rate which leads to maximum of $PM_{10}$ 5.6 and $PM_{2.5}$ with 4.8 times inhalation dose comparing with other modes of transportation. With regards to future studies, the amount of inhalation in each transportation means should be considered in risk assessments of PM.

이차 에어러솔 생성 잠재력 평가를 위한 Potential Aerosol Mass (PAM) 챔버의 제주도 고산 대기분석 적용 (A Preliminary PAM Measurement of Ambient Air at Gosan, Jeju to Study the Secondary Aerosol Forming Potential)

  • 강은하;;김상우;윤순창;정무현;이미혜
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.534-544
    • /
    • 2011
  • The secondary aerosol forming potential of ambient air was first measured with the Potential Aerosol Mass(PAM) chamber at Gosan supersite on Jeju island from October 22 to November 5, 2010. PAM chamber is a small flowthrough photo-oxidation chamber with extremely high OH and $O_3$ levels. The OH exposure in the PAM chamber was $(2{\pm}0.4){\times}10^{11}{\sim}(6{\pm}1.2){\times}10^{11}$ molecules $cm^{-3}$ s and was similar to 2 to 5 days of aging in the atmosphere. By periodically turning on and off UV lamps in the PAM chamber, ambient aerosol and newly formed aerosol (e.g. called as PAM aerosol) was alternately measured. Aerosol number and mass concentration in the range of 10~487 nm in diameter was measured by SMPS 3034. With UV lamps on, the nucleation mode particles smaller than 50 nm in diameters were formed. Their number concentration was greater than 105 $cm^{-3}$, leading to increase in aerosol mass by 0~8 ${\mu}gm^{-3}$. The variations of PAM and ambient aerosols were greatly dependent on characteristics of air masses such as precursor concentrations and degree of aging. This preliminary results suggests that PAM chamber is useful to assess the aerosol formation potential of air mass and its impact on the air quality. The further analysis of data with gaseous and particulate measurements will be done.

일부 학교 내 총부유세균 및 미세먼지의 상관성 비교 (Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces)

  • 서혜경;안하림
    • 한국산업보건학회지
    • /
    • 제34권2호
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

Pulmonary Toxicity and Recovery from Inhalation of Manual Metal Arc Stainless Steel Welding Fumes in Rats

  • Yang, Mi-Jin;Kim, Jin-Sung;Yang, Young-Su;Cho, Jae-Woo;Choi, Seong-Bong;Chung, Yong-Hyun;Kim, Yong-Bum;Cho, Kyu-Hyuk;Lim, Chae-Woong;Kim, Choong-Yong;Song, Chang-Woo
    • Toxicological Research
    • /
    • 제24권2호
    • /
    • pp.119-127
    • /
    • 2008
  • The objectives of this study were to examine the lung injury and inflammation caused by manual metal arc stainless steel(MMA-SS) welding fume inhalation and to evaluate the recovery process. Sprague-Dawley rats were exposed to MMA-SS welding fumes for 2 h per day in a whole-body exposure chamber, with a total suspended particulate(TSP) concentration of $51.4{\pm}2.8mg/m^3$(low dose) or $84.6{\pm}2.9mg/m^3$(high dose) for 30 days. The animals were sacrificed after 30 days of exposure as well as after a 30-day recovery period. To assess the inflammatory or injury responses, cellular and biochemical parameters as well as cytokines were assayed in the bronchoalveolar lavage fluid(BALF). MMA-SS welding fume exposure led to a significant elevation in the number of alveolar macrophages(AM) and polymorphonuclear cells(PMN). Additionary, the values of $\beta$-n-acetyl glucosaminidase($\beta$-NAG) and lactate dehydrogenase(LDH) in the BALF were increased in the exposed group when compared to controls. After 30 days of recovery from exposure, a significant reduction in inflammatory parameters of BALF was observed between the exposed and recovered groups. Slight, but significant elevations were noted in the number of AM and PMN in the recovered groups, and AM that had been ingested fume particles still remain in the lungs. In conclusion, these results indicated that welding fumes induced inflammatory responses and cytotoxicity in the lungs of exposed rats. Fume particles were not fully cleared from lungs even after a 30-day recovery period.