• 제목/요약/키워드: Particulate emissions

검색결과 340건 처리시간 0.024초

중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교 (Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas)

  • 이용기;김웅수;홍순모;신은상
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.

농업지역(밭) 암모니아 등 대기오염물질 계절별 모니터링 연구 (Study on the Emission Characteristics of Air Pollutants from Agricultural Area)

  • 김민욱;김진호;김경식;홍성창
    • 한국환경농학회지
    • /
    • 제40권3호
    • /
    • pp.211-218
    • /
    • 2021
  • BACKGROUND: Fine particulate matter (PM2.5) is produced by chemical reactions between various precursors. PM2.5 has been found to create greater human risk than particulate matter (PM10), with diameters that are generally 10 micrometers and smaller. Ammonia (NH3) and nitrogen oxides (NOx) are the sources of secondary generation of PM2.5. These substances generate PM2.5 through some chemical reactions in the atmosphere. Through chemical reactions in the atmosphere, NH3 generates PM2.5. It is the causative agent of PM2.5. In 2017 the annual ammonia emission recorded from the agricultural sector was 244,335 tons, which accounted for about 79.3% of the total ammonia emission in Korea in that year. To address this issue, the agricultural sector announced the inclusion of reducing fine particulate matter and ammonia emissions by 30% in its targets for the year 2022. This may be achieved through analyses of its emission characteristics by monitoring the PM2.5 and NH3. METHODS AND RESULTS: In this study, the PM2.5 concentration was measured real-time (every 1 hour) by using beta radiation from the particle dust measuring device (Spirant BAM). NH3 concentration was analyzed real-time by Cavity Ring-Down Spectroscopy (CRDS). The concentrations of ozone (O3) and nitrogen dioxide (NO2) were continuously measured and analyzed for the masses collected on filter papers by ultraviolet photometry and chemiluminescence. CONCLUSION: This study established air pollutant monitoring system in agricultural areas to analyze the NH3 emission characteristics. The amount of PM2.5 and NH3 emission in agriculture was measured. Scientific evidence in agricultural areas was obtained by identifying the emission concentration and characteristics per season (monthly) and per hour.

비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구 (A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant)

  • 윤재서;김상민;이예지;노성여
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.506-512
    • /
    • 2018
  • 가정과 요식업 사업장에서 발생하는 미세먼지는 전체 미세먼지 배출량의 약 4%정도로 낮은 비율을 차지하고 있다. 하지만 요식업 사업장에서는 일시적 미세먼지 농도가 최대 60배 가까이 측정될 만큼 오염농도의 변화율이 매우 높다. 비산업 연소 사업장에서 발생하는 오염 물질은 입자상 미세먼지와 가스상 유기화합물로 구성되며, 이 오염물질을 제거하기 위해서 여러 집진원리 중 가스상 물질과 입자상 물질의 동시 제거에 효과적인 시스템인 세정집진을 적용하였다. 이는 이류체 분무 노즐을 이용한 가압수식 액체 분사 방법으로 브라운 운동의 확산 포집의 확률을 높인 방법이다. 제작된 미세먼지 제거 장치를 이용하여 노즐 분무 기압 조건과 각도 등에 따른 미세먼지 집진 시스템의 집진 효율성을 분석하였으며, 그 결과 미세먼지와 가스상 유기화합물 제거효율이 90% 이상을 만족하는 것을 확인하였다. 개발된 시스템은 기존 사업장 후드 시스템에 별도의 설치비용 없이 미세먼지 집진 제거가 가능하여 향후 높은 활용성이 기대된다.

한반도 대기정체의 특성 및 지역기후모델 HadGEM3-RA를 이용한 미래 전망 (Characteristics of Air Stagnation over the Korean Peninsula and Projection Using Regional Climate Model of HadGEM3-RA)

  • 김도현;김진욱;김태준;변재영;김진원;권상훈;김연희
    • 대기
    • /
    • 제30권4호
    • /
    • pp.377-390
    • /
    • 2020
  • Not only emissions, but also atmospheric circulation is a key factor that affects local particulate matters (PM) concentrations in Korea through ventilation effects and transboundary transports. As part of the atmospheric circulation, air stagnation especially adversely affects local air quality due to weak ventilation. This study investigates the large-scale circulation related to air stagnation over Korea during winter and projects the climate change impacts on atmospheric patterns, using observed PM data, reanalysis and regional climate projections from HadGEM3-RA with Modified Korea Particulate matter Index. Results show that the stagnation affects the PM concentration, accompanied by pressure ridge at upper troposphere and weaken zonal pressure gradient at lower troposphere. Downscaling using HadGEM3-RA is found to yield Added-Value in the simulated low tropospheric winds. For projection of future stagnation, SSP5-8.5 and SSP1-2.6 (high and low emission) scenarios are used here. It has been found that the stagnation condition occurs more frequently by 11% under SSP5-8.5 and by 5% under SSP1-2.6 than in present-day climate and is most affected by changes in surface wind speed. The increase in the stagnation conditions is related to anticyclonic circulation anomaly at upper troposphere and weaken meridional pressure gradient at lower troposphere. Considering that the present East Asian winter monsoon is mainly affected by change in zonal pressure gradient, it is worth paying attention to this change in the meridional gradient. Our results suggest that future warming condition increase the frequency of air stagnation over Korea during winter with response of atmospheric circulation and its nonlinearity.

수도권 환경계획을 위한 초미세먼지 농도의 공간 군집특성과 고농도지역 분석 (Spatial clustering of PM2.5 concentration and their characteristics in the Seoul Metropolitan Area for regional environmental planning)

  • 임철희;박득희
    • 한국환경복원기술학회지
    • /
    • 제25권1호
    • /
    • pp.41-55
    • /
    • 2022
  • Social interest in the fine particulate matter has increased significantly since the 2010s, and various efforts have been made to reduce it through environmental plans and policies. To support such environmental planning, in this study, spatial cluster characteristics of fine particulate matter (PM2.5) concentrations were analyzed in the metropolitan area to identify high-risk areas spatially, and the correlation with local environmental characteristics was also confirmed. The PM2.5 concentration for the recent 5 years (2016-2020) was targeted, and representative spatial statistical methods Getis-Ord Gi* and Local Moran's I were applied. As a result of the analysis, the cluster form was different in Getis-Ord Gi* and Local Moran's I, but they show high similarity in direction, therefore complementary results could be obtained. In the high concentration period, the hotspot concentration of the Getis-Ord Gi* method increased, but in Local Moran's I, the HH region, the high concentration cluster, showed a decreasing trend. Hotspots of the Getis-Ord Gi* technique were prominent in the Pyeongtaek-Hwaseong and Yeoju-Icheon regions, and the HH cluster of Local Moran's I was located in the southwest, and the LL cluster was located in the northeast. As in the case of the metropolitan area, in the results of Seoul, there was a phenomenon of division between the northeast and southwest regions. The PM2.5 concentration showed a high correlation with the elevation, vegetation greenness and the industrial area ratio. During the high concentration period, the relation with vegetation greenness increased, and the elevation and industrial area ratio increased in the case of the annual average. This suggests that the function of vegetation can be maximized at a high concentration period, and the influence of topography and industrial areas is large on average. This characteristic was also confirmed in the basic statistics for each major cluster. The spatial clustering characteristics of PM2.5 can be considered in the national land and environmental plan at the metropolitan level. In particular, it will be effective to utilize the clustering characteristics based on the annual average concentration, which contributes to domestic emissions.

숯가마 배가스 중 악취물질의 배출특성 (Emission Characteristics of Odor Compounds in a Charcoal Production Kiln)

  • 박성규;최상진;황의현;이정주;김대근
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.319-326
    • /
    • 2014
  • Exhaust gas emitted as a result of the incomplete combustion of biomass in charcoal kilns includes odor compounds as well as other air pollutants such as particulate matters, sulfur and nitrogen oxides, and carbon monoxide. A number of offensive odor compounds affect quality of life. In this study, odor emissions were investigated from biomass burning in a pilot-scale charcoal kiln and a commercial-scale kiln. Complex odor from emission source reached up to 10,000 dilutions to threshold during the study period. Combustion fume was found to contain reduced sulfur compounds, aldehydes, and volatile organic compounds. Hydrogen sulfide and methyl mercaptan were the major odorants which highly contributed to the offensive odor.

Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교 (Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type)

  • 김민식;권지원;정명철;이진욱
    • 한국분무공학회지
    • /
    • 제17권4호
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

바이오 디젤 적용에 따른 대형엔진의 배출가스 특성 (The Emission Characteristics of Bio-Diesel Fuel in Heavy-Duty Engine)

  • 김선문;엄명도;홍지형
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.499-506
    • /
    • 2010
  • Recently, a great deal of attention have been directed to the use of alternative fuels as a means to reduce vehicular emissions. As one of the promising alternative fuels, bio-diesel has advantages of a wide adaptability without retrofit of diesel engine. It is also effective enough to reduce CO, THC, $SO_x$, polycyclic aromatic hydrocarbons (PAHs) and PM. In this study, we investigated the emission characteristics of biofuels between different operating conditions, i.e., engine speed (1,400 rpm and 2,300 rpm), engine load (10% and 100%), bio-diesel blending (BD0, BD5 and BD20), and recirculation (EGR) rate of exhaust gas (0% and 20%). Relative performance of the system was evaluated mainly for the greenhouse gases ($CH_4$, $N_2O$ and $CO_2$). In addition, emission characteristics of ND-13 mode were also tested against both greenhouse gases and other airborne pollutants under emission regulation. The relative composition of bio-diesel has shown fairly clear effects on the emission quantities of CO, THC, and PM emission, although it was not on $NO_x$ and greenhouse gases. EGR rate has shown trade-off characteristics between $NO_x$ and PM.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at Kwangju Area

  • Son, Bu-Soon;Song, Mi-Ra;Yang, Won-Ho;Chung, Young-Dall;Pack, Jong-An
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.373-377
    • /
    • 2005
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals and from chemicals are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCS and particulate matter($PM_{10}$) during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and PM lo were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor sources and outdoor sources. Therefore, proper management methods should be taken to improve the indoor air quality in beauty shops.

  • PDF

기계식 부압발생장치를 이용한 매연여과장치의 성능비교 (Performance Comparison of Soot Filtration Apparatus Using a Mechanical Negative Pressure Generating Device)

  • 이한성;김경현;정석호;고대권
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engines. The air pollutant emissions from the diesel engines are still significant concerns environmentally in many countries. In the present study, a novel smoke filtration system of diesel engine is proposed. This novel system is composed of filtering elements and vacuum pump driven by exhaust gases emitted from engine cylinders for capturing smoke. In order to verify the excellency of the novel filtration system, the differential pressure across the filtration system is investigated experimentally comparing with other systems which are used commercially in diesel vehicles. As a result it is founded that the differential pressure of the novel system is the smallest among them.