• 제목/요약/키워드: Particulate Matter (PM10)

검색결과 707건 처리시간 0.026초

노인의 미세먼지 관련 건강행위와 영향요인 (Factors Influencing Health Behavior Related to Particulate Matter in Older Adults)

  • 박민경;김광숙
    • 대한간호학회지
    • /
    • 제50권3호
    • /
    • pp.431-443
    • /
    • 2020
  • Purpose: This study aimed to investigate health behavior related to particulate matter (PM) in older adults and examine the factors affecting it. Methods: A cross-sectional survey design was used. Data were collected from 150 voluntary older adult participants from Songpa-gu in Seoul. The survey questions measured service perception and experience related to PM, risk perception related to PM, attitude toward risk of PM, and health behavior related to PM. Results: The average score for health behavior related to PM was 79.37, ranging from 51 to 115. There was a significant positive correlation between health behavior related to PM and risk perception related to PM (r=.58, p<.001) as well as between health behavior related to PM and attitude toward risk of PM (r=.70, p<.001). Multiple linear regression revealed that health behavior related to PM was predicted by levels of the existence of disease related to PM (β=.14, p=.019), service experience related to PM (β=.20, p=.021), risk perception related to PM (β=.20, p=.019), and attitude toward risk of PM (β=.44, p<.001). The model including these variables accounted for 47.0% of health behavior related to PM. Conclusion: Korean older adults have the low level of health behavior related to PM. The findings of this study emphasize that risk perception and attitude toward risk of PM should be evaluated, and the underlying diseases related to PM and their service experience should be considered in developing intervention to improve health behavior related to PM.

광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발 (Development of Drying Systems for Accurate Measurement of Particulate Matter by means of Optical Particle Measuring Instruments)

  • 강두수;오정은;이상열;신희준;봉하경;최주현;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.191-203
    • /
    • 2018
  • IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.

Evaluation of the microbiome composition in particulate matter inside and outside of pig houses

  • Hong, Se-Woon;Park, Jinseon;Jeong, Hanna;Kim, Minseok
    • Journal of Animal Science and Technology
    • /
    • 제63권3호
    • /
    • pp.640-650
    • /
    • 2021
  • Particulate matter (PM) produced in pig houses may contain microbes which can spread by airborne transmission, and PM and microbes in PM adversely affect human and animal health. To investigate the microbiome in PM from pig houses, nine PM samples were collected in summer 2020 inside and outside of pig houses located in Jangseong-gun, Jeollanam-do Province, Korea, comprising three PM samples from within a nursery pig house (I-NPH), three samples from within a finishing pig house (I-FPH), and three samples from outside of the pig houses (O-PH). Microbiomes were analyzed using 16S rRNA gene amplicon sequencing. Firmicutes was the most dominant phylum and accounted for 64.8%-97.5% of total sequences in all the samples, followed by Proteobacteria (1.4%-21.8%) and Bacteroidetes (0.3%-13.7%). In total, 31 genera were represented by > 0.3% of all sequences, and only Lactobacillus, Turicibacter, and Aerococcus differed significantly among the three PM sample types. All three genera were more abundant in the I-FPH samples than in the O-PH samples. Alpha diversity indices did not differ significantly among the three PM types, and a principal coordinate analysis suggested that overall microbial communities were similar across PM types. The concentration of PM did not significantly differ among the three PM types, and no significant correlation of PM concentration with the abundance of any potential pathogen was observed. The present study demonstrates that microbial composition in PM inside and outside of pig houses is similar, indicating that most microbe-containing PM inside pig houses leaks to the outside from where it, along with microbe-containing PM on the outside, may re-enter the pig houses. Our results may provide useful insights regarding strategies to mitigate potential risk associated with pig farming PM and pathogens in PM.

Effects of Antioxidant on Oxidative Stress and Autophagy in Bronchial Epithelial Cells Exposed to Particulate Matter and Cigarette Smoke Extract

  • Hur, Jung;Rhee, Chin Kook;Jo, Yong Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • 제85권3호
    • /
    • pp.237-248
    • /
    • 2022
  • Background: We evaluated the effect of particulate matter (PM) and cigarette smoke extract (CSE) on bronchial epithelial cell survival, as well as oxidative stress and autophagy levels. Moreover, we aimed to assess the effect of the antioxidant N-acetylcysteine (NAC) on the adverse effects of PM and CSE exposure. Methods: Normal human bronchial epithelial cells (BEAS-2B cells) were exposed to urban PM with or without CSE, after which cytotoxic effects, including oxidative stress and autophagy levels, were measured. After identifying the toxic effects of urban PM and CSE exposure, the effects of NAC treatment on cell damage were evaluated. Results: Urban PM significantly decreased cell viability in a concentration-dependent manner, which was further aggravated by simultaneous treatment with CSE. Notably, pretreatment with NAC at 10 mM for 1 hour reversed the cytotoxic effects of PM and CSE co-exposure. Treatment with 1, 5, and 10 mM NAC was shown to decrease reactive oxygen species levels induced by exposure to both PM and CSE. Additionally, the autophagy response assessed via LC3B expression was increased by PM and CSE exposure, and this also attenuated by NAC treatment. Conclusion: The toxic effects of PM and CSE co-exposure on human bronchial epithelial cells, including decreased cell viability and increased oxidative stress and autophagy levels, could be partly prevented by NAC treatment.

승용디젤엔진의 과도구간 입자상물질 저감 및 운전성능 향상을 위한 연료분사량 및 커먼레일압력 제어전략 (A Control Strategy of Fuel Injection Quantity and Common-rail Pressure to Reduce Particulate Matter Emissions in a Transient State of Diesel Engines)

  • 홍승우;정동혁;선우명호
    • 한국자동차공학회논문집
    • /
    • 제23권6호
    • /
    • pp.623-632
    • /
    • 2015
  • This study proposes a control strategy of the common rail pressure with a fuel injection limitation algorithm to reduce particulate matter (PM) emissions under transient states. The proposed control strategy consists of two parts: injection quantity limitation and rail pressure adaptation. The injection limitation algorithm determines the maximum allowable fuel injection quantity to avoid rich combustion under transient states. The fuel injection quantity is limited by predicting the burned gas rate after combustion; however, the reduced injection quantity leads to deterioration of engine torque. The common rail pressure adaptation strategy is designed to compensate for the reduced engine torque. An increase of the rail pressure under transient states contributes to enhancement of the engine torque as well as reduction of PM emissions by promoting atomization of the injected fuel. The proposed control strategy is validated through engine experiments. The rail pressure adaptation reduced the PM emission by 5-10% and enhanced the engine torque up to 2.5%.

초등학교 실내외 미세먼지 농도 비교 연구 (A Comparative Study on Concentrations of Indoor and Outdoor Particulate Matters in Elementary Schools)

  • 김대현;손윤석;이태정;조영민
    • 대한원격탐사학회지
    • /
    • 제36권6_3호
    • /
    • pp.1721-1732
    • /
    • 2020
  • 초등학생들은 학교에서 많은 시간을 보내고 있으며 실내 공기오염에 더 많이 노출된다. 또한 초등학생들은 신체적으로 성장기에 있으며 어른에 비해 단위체중당 호흡량이 많으므로 실내 공기오염에 대한 민감도가 큰 것으로 알려져 있다. 따라서 학교 실내공기질은 초등학생들의 건강을 위한 중요한 요소이다. 본 연구에서는 서울지역 5개 초등학교에서 측정한 실내외 미세먼지 (Particulate matter: PM) 농도를 이용하여 상관분석을 실시하였다. 이를 통해 실외 PM이 실내 PM에 미치는 영향을 평가하였다. 또한 PM ratio, I/O ratio 등과 같은 통계분석을 진행하였다. 그 결과 초등학교의 실내외 PM의 상관성은 PM10보다 PM2.5와 PM1에서 더 유의미하게 나타났다. Indoor/outdoor (I/O) ratio의 경우 PM10에서 SD를 제외한 4개 초등학교에서 모두 1보다 높게 나타났다 (BB: 2.21, NS: 1.67, IS: 1.73, SI: 1.17). 이는 실내 학생의 활동도가 PM10의 농도에 큰 영향을 미친다는 것을 의미한다.

대전 3, 4 공단지역의 미세분진에 대한 화학적 특성과 오염원 연구 (Chemical characteristics and sources of fine ambient particulate matter from the third and fourth industrial complex area of Daejeon city, Korea)

  • 임종명;이진홍;정용삼
    • 분석과학
    • /
    • 제20권1호
    • /
    • pp.33-40
    • /
    • 2007
  • 대전시 3, 4 공단지역의 대기 중 미세분진을 대상으로 기기 중성자방사화분석법을 이용하여 유해금속을 포함한 약 27종의 미량원소를 분석하였다. 원소분석에 대한 정확도를 평가하기 위해 NIST SRM 2783(air particulate on filter media)을 사용하여 동일한 조건에서 분석한 결과, Sb, Mn, V, Mg, Na, K, Ti, Co, Zn, Sm은 상대오차 5% 이내의 매우 정확한 분석결과를 보였고 Cr, Fe, Ba, Th, Ce, Al, Cu는 10% 이내로 나타났다. 유해금속인 As, Mn, Se, V, Zn의 농도는 각각 $3.26{\pm}2.72$, $9.86{\pm}4.71$, $2.18{\pm}1.25$, $4.91{\pm}2.41$, $158{\pm}78ng/m^3$로 나타났고 인자분석 결과 연구대상지역의 미세분진에 대한 오염원은 6개로 추정되었다.

INAA.ICP.AAS를 이용한 대기먼지 $(PM_{10})$의 다원소분석 (Multielement Analysis in Airborne Particulate Matter $(PM_{10})$ by INAA, ICP and AAS)

  • 정용삼;문종화;정영주;박광원;이길용;윤윤열;심상권;조경행;한명섭
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.495-503
    • /
    • 1999
  • Airborne particulate matter $(PM_{10})$ collected using high volume air sampler and silica fiber filter were analyzed by Instrumental Neutron Activation Analysis(INAA), Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) and Atomic Absorption Spectrometry(AAS), and the results were compared with each other. 30~40 trace elements in environmental standard reference materials(NIST SRM 1648 and NIES CRM No.8) were analyzed for the analytical quality control. The relative error for two-third of elements detected was less than 10%, and the standard deviation was less than 15%. During the sampling period for 24 hours, the mass concentration of total suspended particulate was 36.1$\mu\textrm{g}$/㎥ and the value is lower than the critical level in Korea. In the results of NAA, the elements of Al, As, Ba, Fe, La, Mg, Na, Sb, Zn were well agreed with those of other methods. In statistical estimation between different methods, the deviation of Al, Ba, Cr, Fe was less than 10% and quite reliable.

  • PDF

Measurement and Interpretation of Time Variations of Particulate Matter Observed in the Busan Coastal Area in Korea

  • Kim, Cheol-Hee;Son, Hye-Young
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권2호
    • /
    • pp.105-112
    • /
    • 2011
  • In order to investigate the effects of local and synoptic meteorological conditions on urban scale particulate air pollutants observed over the Busan coastal area, power spectrum analysis was applied to observed particulate matter with an aerodynamic diameter $\leq10\;{\mu}m$ ($PM_{10}$) for the period from 1 October, 1993 to 31 December, 2004. Fast Fourier Transform (FFT) analysis was used to obtain the hourly mean observed $PM_{10}$ concentrations to identify different periodicity scales of $PM_{10}$ concentrations. The results showed that, aside from the typical and well-known periodicities such as diurnal and annual variations caused by anthropogenic influences, three other significant power spectral density peaks were identified: 7-day, 21-day and 2.25-year periodicities. Cospectrum analysis indicated that the seven-day variations were closely related to the synoptic meteorological conditions such as weak wind speed, which are relevant to the stagnant high pressure system slowly passing through the Korean Peninsula. The intra-seasonal 21-day variation was negatively correlated with wind speed but was consistently positively correlated with relative humidity, which is related to aerosol formation that can be achieved as a result of the hygroscopic characteristics of aerosols. However, the quasibiennial 2.25-year variation was correlated with the frequency of Asian dust occurrence, the periodicities of which have been recorded inter-annually over the Korean Peninsula.

OXIDATION CHARACTERISTICS OF PARTICULATE MATTER ON DIESEL WARM-UP CATALYTIC CONVERTER

  • Choi, B.C.;Yoon, Y.B.;Kang, H.Y.;Lim, M.T.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.527-534
    • /
    • 2006
  • Modern passenger cars with diesel engines are equipped with DOC(diesel oxidation catalyst) for the purpose of reducing HC and CO in the exhaust stream. Cold start exhaust emissions pose troubles here as on gasoline engine vehicles. As a result, some of the diesel passenger cars roll off todays the assembly lines with WCC(warm-up catalytic converter). Oxidation characteristics of the particulates in WCC is analyzed in this study by EEPS(engine exhaust particulate size spectrometer). The maximum number of PM is found to come out of WCC in sizes near 10nm when an HSDI diesel engine is operated under the conditions of high speed and medium to heavy load. When the temperature of the WCC exceeds $300^{\circ}C$, the number of PM smaller than 30 nm in diameter sharply increases upon passing through the WCC. Total mass of emitted PM gets reduced downstream of the WCC under low speed and light load conditions due to adsorption of PM onto the catalyst. Under conditions of high speed and medium to heavy load, the relatively large PM shrink or break into fine particles during oxidation process within the WCC, which results in more mass fraction of fine particles downstream of the WCC.