Abstract
Elementary school students spend a lot of time in a school and are more exposed to indoor air pollution. Also the students are physically growing and have a relatively high respiratory rate per unit weight compared to adults, so it is known that there is a high sensitivity to indoor air pollution. Therefore, indoor air quality in a school is becoming an important factor for the student's health. In this study, a correlation analysis using levels of indoor and outdoor Particulate Matter (PM) measured from five elementary schools in Seoul was performed to evaluate the effect of outdoor PM on indoor PM. PM ratio and indoor/outdoor (I/O) ratio were also analyzed to investigate the actual condition of indoor air quality and effect of outdoor PM on indoor PM. As a result, the correlation between indoor and outdoor PM in elementary school was more significant in PM2.5 and PM1 than PM10. In the case of I/O ratio, the I/O ratio of PM10 was higher than that of 1 in four elementary schools except SD (BB:2.21, NS: 1.67, IS: 1.73, SI: 1.17). This indicates that the activity of students has a great effect on the concentration of indoor PM10.
Keywords
Indoor air quality; Particulate matter; $PM_{2.5}$; $PM_1$; I/O ratio;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Yang, W. H., J. R. Sohn, J. Kim, B. S. Son, and J. C. Park, 2009. Indoor air quality investigation according to age of the school buildings in Korea, Journal of Environmental Management, 90(1): 348-354 (in Korean with English abstract).   DOI
2 Alshitawi, M. S. and H. B. Awbi, 2011. Measurement and prediction of the effect of student's activities on airborne particulate concentration in a classroom, HVAC&R Research, 17(4): 446-464.
3 Bae, G. N. and J. H. Ji, 2013. Management policy and control technology for indoor air quality in Korea, Journal of Korean Society for Atmospheric Environment, 29(4): 378-389 (in Korean with English abstract).   DOI
4 Choi, C. K., S. Y. Yoo, and B. K. Jeon, 2000. A Study on the Characteristics of Concentrations of Atmospheric Aerosols in Pusan, Korean Journal of Environmental Health Society, 26: 41-48 (in Korean with English abstract).
5 Choi, Y. A., T. J. Lee, and D. S. Kim, 2006. Investigation of indoor air quality and characteristics of particulate matters concentration followed by indoor activities in preschool, Journal of Korean Society for Indoor Environment, 3(3): 237-284 classrooms (in Korean with English abstract).
6 Choi, Y. J., G. Y. Lee, G. H. Baek, and N. E. Kang, 2017. Difference Analysis on Indoor Air Quality by Ventilation during Sleeping Time in University Housing, Korean Journal of Human Ecology, 26(6): 609-622 (in Korean with English abstract).   DOI
7 Deng, Q., L. Deng, Y. Miao, X. Guo, and Y. Li, 2019. Particle deposition in the human lung: Health implications of particulate matter from different sources, Environmental Research, 169: 237-245.   DOI
8 Jung, Y. S., L. S. Kwon, and S. H. Kim, 2016. A study on the measurement of indoor air quality of Kindergartens located in Suwon-si, South Korea, Journal of the Korean Society of Urban Environment, 16(4): 523-529 (in Korean with English abstract).
9 Donaldson, K., X. Y. Li, and W. MacNee, 1998. Ultrafine (nanometre) particle mediated lung injury, Journal of Aerosol Science, 29(5-6): 553-560.   DOI
10 Jeung, Y. H. and S. J. Choi, 2007. Assessment of formaldehyde concentration in indoor and outdoor environments of schools in Incheon, Korean Journal of Environmental Health, 33(5): 372-378, (in Korean with English abstract).
11 Kim, J. H., T. J. Lee, I .J. Hwang, and D. S. Kim, 2008. Investigation of indoor air quality and the characteristics of particulate matter distribution in a university library, Journal of Korean Society for Indoor Environment, 5(1): 24-36 (in Korean with English abstract).
12 Klepeis, N. E., W. C. Nelson, W. R. Ott, J. P. Robinson, A. M. Tsang, P. Switzer, J. V. Behar, S. C. Hern, and W. H. Engelmann, 2001. The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants, Journal of Exposure Analysis and Environmental Epidemiology, 11(3): 231-252.   DOI
13 Sim, S. H. and Y. S. Kim, 2006. Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde-, Korean Journal of Environmental Health Science, 32(4): 275-281 (in Korean with English abstract).
14 Koenig, J. Q., T. F. Mar, R. W. Allen, K. Jansen, T. Lumley, J. H. Sullivan, C. A. Trenga, T. Larson, L. J. Liu, 2005. Pulmonary Effects of Indoor and Outdoor Generated Particles in Children with Asthma, Environmental Health Perspectives, 113(4): 499-503.   DOI
15 Oh, H. J., I. S. Nam, H. Yun, J. Kim, and J. Yang, 2014. Characterization of indoor air quality and efficiency of air purifier in childcare centers, Korea, Building and Environment, 82: 203-214.   DOI
16 Park, D. W., S. H. Kim, and H. J. Yoon, 2017. The impact of indoor air pollution on asthma, Allergy Asthma Respiratory Disease, 5(6): 312-319 (in Korean with English abstract).   DOI
17 Park, S., T. Park, S. Park, Y. Kim, M. Kwon, J. Jung, and C. Lee, 2018. Levels of the concentration of PM10 and PM2.5 in elementary school classroom at Yeongwol county, Journal of Odor and Indoor Environment, 17(1): 11-17 (in Korean with English abstract).   DOI
18 Seoul Traffic Research., 2019. https://topis.seoul.go.kr/refRoom/openRefRoom_2.do. Acessed on Dec. 5, 2020.
19 Sin, E. Y. and G. H. Kim, 2017. A study on university office worker's perception of indoor air quality (Focused on K university), The Journal of Design and Educational Environmental Research, 16(3): 69-76.
20 Son, Y. S., 2020. Particulate matter and influencing factors in domestic elementary schools, Journal of Korean Society for Atmospheric Environment, 36(2): 153-170 (in Korean with English abstract).   DOI
21 Yang, W. H., 2014. Time-activity pattern of students and indoor air quality of school, Korean Institute of Educational Facilities, 21(6): 17-22 (in Korean with English abstract).
22 Suh, J. M., B. Wang, S. H. Jang, J. H. Park, and K. C. Choi, 2014. Characteristics of Size segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings, Journal of Korean Society of Occupational and Environmental Hygiene, 24(4): 453-461 (in Korean with English abstract).   DOI
23 Yang, J., I. Nam, H. Yun, J. Kim, H. J. Oh, D. Lee, S. M. Jeon, S. H. Yoo, and J. R. Sohn, 2015. Characteristics of indoor air quality at urban elementary schools in Seoul, Korea: Assessment of effect of surrounding environments, Atmospheric Pollution Research, 6: 1113-1122.   DOI