• Title/Summary/Keyword: Particle separation

Search Result 480, Processing Time 0.026 seconds

Effect of the Particle Size and Unburned Carbon Content on the Separation Efficiency of Fly ash in the Countercurrent Column Flotation (向流컬럼浮選機에서 石炭灰의 크기 및 未燃炭素 含量이 分離特性에 미치는 영향)

  • 이정은;이재근
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.36-44
    • /
    • 2000
  • Fly ash was composed of the unburned carbon and mineral particles. The former was able to attach on the bubbles, while the latter was not. Therefore, it was possible to separate the unburned carbon and the mineral from fly ash using the froth flotation process. This study was carried out to evaluate the separation efficiency as a function of the ny ash particle properties in the column flotation. Separation efficiency was analyzed for various size fraction of -38 fm,38~125 fm and 1125 W, and for various fly ash samples containing 7, 11, and 20 wt% unburned carbon. For the size fractions of -38 fm containing 7 wt% unburned carbon, separation efficiency was 86ft, whereas separation efficiency was found to be 74% for the size fraction of +125$\mu\textrm{m}$ containing 20 wt% unburned carbon. The results indicated that separation efficiency increased with the decrease in the particle size and the unburned carbon content of the fly ash.

  • PDF

Flow Characteristics of Neutrally Buoyant Particles in 2-Dimensional Poiseuille Flow through Circular Capillaries

  • Kim, Young-Won;Jin, Song-Wan;Yoo, Jung-Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.7-10
    • /
    • 2006
  • An experimental study has been conducted to quantitatively characterize the motion of neutrally buoyant particles in 2-dimensional Poiseuille flow through the micron-sized circular capillaries in the range of Re (Reynolds number) $\approx0.1\sim100$. $A{\mu}-PTV$ (Particle Tracking Velocimetry) system is adopted, which consists of a double-headed Nd:YAG laser, an epi-fluorescence microscope and a cooled CCD camera. Since high shear rate can be induced due to the scale effect even at low Re, it is shown that in micro scale neutrally buoyant particles in Poiseuille flow drift away from the wall and away from the center of the capillary. Consequently, particles accumulate at the equilibrium position of $0.52\sim0.64R$ with R being the radius of the capillary, which is analogous to that of tube flow in macro scale. There is a plateau in equilibrium position at small Re, while equilibrium position starts increasing at $Re\approx30$. The outermost edge of particle cluster is closer to the center of the capillary than that in previous studies due to low Re effect. The present study quantitatively presents characteristics of particle motion in circular capillaries. Furthermore, it is expected to give optimum factors for designing microfluidic systems that are to be used fur plasma separation from the blood.

  • PDF

Development of Ceramic Composite Membranes for Gas Separation: II. Preparation and Coating Characteristics of Nanoparticulate $TiO_2$ Sols (기체분리용 세라믹 복합분리막의 개발: II. 극미세 입자 $TiO_2$ 졸의 제조 및 코팅 특성)

  • 현상훈;박준수;최세영
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.9
    • /
    • pp.739-749
    • /
    • 1992
  • The sols prepared by dialyzing solutions, in which the hydrolyzed precipitates of TEOT or directly Ti(OC3H7)4 were resolved, were the nanoparticulate sol with the average particle size less than 7 nm and the anatase crystal phase. In the pH range of 1.5 to 2.9, the particle size of the nanoparticulate TiO2 sols (0.09 mol/ι) increased gradually upto 15 nm~26nm with the increase of pH in the initial aging state but the sols were transparent all the time, and stable without growin any more after 30 days. When the slipcasted porous alumina tubes were coated by the sol-gel dipping method, the minimum particle size and the aging time for forming the coated gel layer at the given pH were optimized. For obtaining the very thin crack-free and reproducible membrane coating, the use of a nanoparticulate TiO2 sol (0.09 mol/ι) aged for about 30 dyas at pH=2.0 was found to be the best.

  • PDF

The Preparation of D-Phenylalanine Imprinted Microbeads by a Novel Method of Modified Suspension Polymerization

  • Khan, Hamayun;Park, Joong-Kon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.503-509
    • /
    • 2006
  • Molecularly imprinted polymeric microbeads (MIPMs) were prepared by the suspension and modified suspension polymerization methods using D-phenylalanine as the template, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, toluene as the porogen, polyvinyl alcohol as the stabilizer, and sodium dodecyl sulfate as the surfactant. The addition of a surfactant to the conventional suspension polymerization mixture decreased the mean particle size of the MIPMs and increased the adsorption selectivity. For the modified suspension polymerization method, the mean particle size of the MIPMs was smaller than the particle size of MIPMs prepared via conventional suspension polymerization. Moreover, the adsorption selectivity improved considerably compared to the adsorption selectivities of MIPs reported previously.

Nanometrology and its perspectives in environmental research

  • Kim, Hyun-A;Seo, Jung-Kwan;Kim, Taksoo;Lee, Byung-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.16.1-16.9
    • /
    • 2014
  • Objectives Rapid increase in engineered nanoparticles (ENPs) in many goods has raised significant concern about their environmental safety. Proper methodologies are therefore needed to conduct toxicity and exposure assessment of nanoparticles in the environment. This study reviews several analytical techniques for nanoparticles and summarizes their principles, advantages and disadvantages, reviews the state of the art, and offers the perspectives of nanometrology in relation to ENP studies. Methods Nanometrology is divided into five techniques with regard to the instrumental principle: microscopy, light scattering, spectroscopy, separation, and single particle inductively coupled plasma-mass spectrometry. Results Each analytical method has its own drawbacks, such as detection limit, ability to quantify or qualify ENPs, and matrix effects. More than two different analytical methods should be used to better characterize ENPs. Conclusions In characterizing ENPs, the researchers should understand the nanometrology and its demerits, as well as its merits, to properly interpret their experimental results. Challenges lie in the nanometrology and pretreatment of ENPs from various matrices; in the extraction without dissolution or aggregation, and concentration of ENPs to satisfy the instrumental detection limit.

Research and development of centrifugal classifiers: A review (회전체 분급기의 원리 및 연구 개발 동향)

  • Song, Dong Keun;Han, Bangwoo;Kim, Hakjoon;Kim, Yong Jin;Jeong, Sang Hyun;Hong, Won Seok
    • Particle and aerosol research
    • /
    • v.4 no.2
    • /
    • pp.37-50
    • /
    • 2008
  • Concerns on centrifugal classifiers, of which have cut sizes are below few micrometers, have been increased and it is prospected to be used in extensive industries, such as manufacturing the fine minerals, cosmetics, advanced electric materials, and life science. This paper reviews the recent progress of research and development on the centrifugal classifiers. General categorization of classifiers for feeds was assessed and separation mechanism of the classifiers was followed. History of centrifugal classifiers was explored and some points to be improved were briefly indicated. Fundamental theory of the classification by centrifugal classifiers was pearly studied, and advanced and further understandings on factors affecting the separation or grading efficiency are described. Factors determining the classification precision and efficiency of centrifugal classifiers, such as geometry, rotational speed and inclined angle of rotating vanes, feed and air flow rates, and rotor dimensions are reviewed.

  • PDF

A Research on the Vector Search Algorithm for the PIV Flow Analysis of image data with large dynamic range (입자의 이동거리가 큰 영상데이터의 PIV 유동 해석을 위한 속도벡터 추적 알고리즘의 연구)

  • Kim Sung Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.13-18
    • /
    • 1998
  • The practical use of the particle image velocimetry(PIV), a whole-field velocity measurement method, requires the use of fast, reliable, computer-based methods for tracking velocity vectors. The full search block matching, the most widely studied and applied technique both in area of PIV and Image Coding and Compression, is computationally costly. Many less expensive alternatives have been proposed mostly in the area of Image Coding and Compression. Among others, TSS, NTSS, HPM are introduced for the past PIV analysis, and found to be successful. But, these algorithms are based on small dynamic range, 7 pixels/frame in maximum displacement. To analyze the images with large displacement, Even and Odd field image separation and a simple version of multi-resolution hierarchical procedures are introduced in this paper. Comparison with other algorithms are summarized. A Results of application to the turbulent backward step flow shows the improvement of new algorithm.

  • PDF

Recover of gypsum from waste plaster board and the refining process

  • Song, Young-Jun;Hiroki Yotsumoto
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.342-348
    • /
    • 2001
  • This study was conducted to obtain granular crystalline gypsum that can be used as raw material for plaster boards or cements from waste Plaster board. We could disintegrate preferentially gypsum to gypsum needle in 10${\mu}{\textrm}{m}$ or less size among the contents of waste plaster board (gypsum, paper, fiber, and inorganic material .etc.) by hydration afterwards the dehydration of crushed waste plaster board. In this case, the optimum conditions for minimizing the size of gypsum were dehydration rate of 75%~ 85%, hydration concentration of 10~20%, agitation speed of 250~400rpm, crushing size of 2cm or less. Gypsum of 98.21% grade was recovered with 99.0% yield from under screenings of 325mesh wet screening which followed by the dehydration-hydration process performed in the conditions of dehydration rate of 80%, hydration concentration of 15%, agitation speed of 300rpm, crushing size of 2cm or less. Subsequently, Plate-like Crystalline gypsum of is 151${\mu}{\textrm}{m}$ size and the grade of 99.49% with the Yield of 98.0% from the upper screenings of 270mesh wet screening carried out after the re-crystallization of the recovered gypsum needle slurry.

  • PDF

Recovery and Refining Process of Gypsum from Waste Plaster Board

  • Song, Young-Jun;Hiroki Yotsumoto
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.43-52
    • /
    • 2001
  • This study was conducted to obtain granular crystalline gypsum that can be used as raw material for Plaster boards or cements from waste Plaster board. Gypsum could be Preferentially disintegrated to gypsum needle in $10\mu\textrm{m}$ or less size by hydration after the dehydration of crushed waste Plaster board. The finer the gypsum needle, it is easier to remove coarse impurities and to recover the gypsum needle. The optimum conditions for obtain the finer gypsum size were dehydration rate of 75~85%, solid concentration at hydration of 10~15%, agitation speed of 250~400 rpm, crushing size before dehydration of 2 cm or less. Gypsum of 98.21% grade was recovered with 99.0% yield as the undersize of 325 mesh wet screening followed by the dehydration-hydration process performed at the conditions of dehydration rate of 80%, solid concentration at hydration of 15%, agitation speed of 300 rpm, crushing size before dehydration of 2 cm or less. After the recrystallization of recovered gypsum, Plate-like gypsum of $151\mu\textrm{m}$ size with 99.49% grade was obtained as the oversize of 270 mesh in a wet screening.

  • PDF

Preparation and Application of Functional Microsphere (II) Formation and Characteristics of Poly(ethylene-co-vinylacetate) Microsphere with Disperse Dye (기능성 마이크로스피어의 제조와 응용(II) 분산염료를 함유한 에틸렌-비닐아세테이트 중합체의 마이크로스피어 제조와 특성)

  • Lee, Shin-Hee;Cho, Hyun;Park, Soo-Min
    • Fashion & Textile Research Journal
    • /
    • v.10 no.3
    • /
    • pp.371-376
    • /
    • 2008
  • Poly(ethylene-co-vinylacetate) (EVA) microspheres were prepared by thermally induced phase separation (TIPS) in toluene. The microsphere formation occurred by the nucleation and growth mechanism in metastable region. The effects of the concentration and component of the polymer and cooling rate on microsphere formation were investigated. The microsphere formation and growth were followed by the cloud point of the optical microscope measurement. The microsphere size distribution, which was obtained by particle size analyzer, became broader when the polymer concentration was higher, the content of vinyl acetate in EVA copolymer was higher, the cooling rate of EVA copolymer solution were lower. The content of disperse dye in EVA microsphere was obtained by TGA thermal analysis, the dye content of EVA15 and EVA18 were 3.5 and 2.0 wt% respectively.