• Title/Summary/Keyword: Particle mass concentration

Search Result 277, Processing Time 0.021 seconds

Characteristics of the Springtime Weekday/Weekend on Mass and Metallic Elements Concentrations of PM10 and PM2.5 in Busan (부산지역 봄철 주중/주말의 PM10과 PM2.5 질량농도와 금속이온농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.777-784
    • /
    • 2015
  • This study investigates weekday/weekend characteristics of $PM_{10}$ and $PM_{2.5}$ concentration and metallic elements in Busan in the springtime of 2013. $PM_{10}$ concentration on weekday/weekend were 77.54 and $67.28{\mu}g/m^3$, respectively. And $PM_{2.5}$ concentration on weekday/weekend were 57.81 and $43.83{\mu}g/m^3$, respectively. Also, $PM_{2.5}/PM_{10}$ concentration ratio on weekdays/weekend was 0.75 and 0.65, respectively. The contribution rates of Na to total metallic elements in $PM_{10}$ on weekday/weekend were 38.3% and 38.9%, respectively. It would be useful in control effectively with management of urban fine particle to understand characteristics of fine particle concentration on weekday/weekend.

The Characteristics of the Aerosol Number Concentration in Jeju Area During Asian Dust Events (황사 시 제주지역 에어로졸의 수농도 특성)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.347-358
    • /
    • 2013
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan in Jeju Island, which is known as background area in Korea, from March 2010 to February 2011. The obtained results of asian dust events and non-asian dust period have been compared. The results show that the entire averaged aerosol number concentration from APS measurement during asian dust events and non-asian dust period are about 341 particles/$cm^3$ and 240 particles/$cm^3$, respectively. During asian dust events, the number concentration in small size ranges(${\leq}0.4{\mu}m$) are similar to non-asian dust period, however, those in large size ranges(${\geq}0.7{\mu}m$) are very higher than non-asian dust period. The contributions of the size resolved number concentration(23 channel in $0.25{\sim}10.0{\mu}m$) to total number concentration in that range are dramatically decreased with increased particle size. The contributions of smaller size ranges(${\leq}0.4{\mu}m$) during asian dust events are very low compared with non-asian dust period, on the other hand, those of larger size ranges(${\geq}0.4{\mu}m$) are higher than non-asian dust period. The number concentration in each size range are strongly correlated with the concentration in adjacent size range. And the total aerosol number concentration are depended on the number concentration in range of smaller than $0.58{\mu}m$ during non-asian dust period and asian dust events. On the other hand, $PM_{10}$ mass concentration has mainly affected with the number concentration in range of smaller than $1.0{\mu}m$ during non-asian dust period, however, during asian dust events, the mass concentration has mainly affected with the number concentration in range of $0.65{\sim}3.0{\mu}m$.

Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions (측정방법 및 기상상태에 따른 PM-10 질량농도 비교)

  • Jung, Chang Hoon;Park, Jin Hee;Hwang, S.M.;Jung, Y.G.
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.

Vertical Change in Extinction and Atmospheric Particle Size in the Boundary Layers over Beijing: Balloon-borne Measurement

  • Chen, Bin;Shi, Guang-Yu;Yamada, Maromu;Zhang, Dai-Zhou;Hayashi, Masahiko;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.3
    • /
    • pp.141-149
    • /
    • 2010
  • Aerosol size and number concentration were observed in the atmospheric boundary layer over Beijing (from near the ground to 1,200 m) on March 15 (a clear day) and 16 (a dusty day), 2005. The results were further compared with lidar measurements in order to understand the dependency of extinction on the particle size distribution and their vertical changes. The boundary layer atmosphere was composed of several sub-layers, and a dry air layer appeared between 400 and 1,000 m under the influence of dust event. In this dry air layer, the concentration of the fine-mode particles (diameter smaller than $1.0\;{\mu}m$) was slightly lower than the value on the clear day, while the concentration of coarse-mode particles (diameter larger than $1.0\;{\mu}m$) was remarkably higher than that on the clear day. This situation was attributed to the inflow of an air mass containing large amounts of Asian dust particles and a smaller amount of fine-mode particles. The results strongly suggest that the fine-mode particles affect light extinction even in the dusty atmosphere. However, quantitatively the relation between extinction and particle concentration is not satisfied under the dusty atmospheric conditions since laser beam attenuates in the atmosphere with high concentration of particles. Laser beam attenuation effect becomes larger in the relation between extinction and coarse particle content comparing the relation between extinction and fine particle content. To clarify this problem technically, future in situ measurements such as balloon-borne lidar are suggested. Here extinction was measured at 532 nm wavelength. Measurements of extinction at other wavelengths are desired in the future.

Characteristics of the dry deposition fluxes and ambient particl size distributions of PCBs: The measurements on fall, 1999 (입자상 PCBs 건식침적량과 입경분포 특성: 1999년 가을 측정)

  • Shin, Hye Jung;Kim, Yong Pyo;Yi, Seung Muk
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.179-188
    • /
    • 2009
  • The dry deposition fluxes of particulate polychlorinated biphenyls (PCBs) were measured along with their mass size distributions at Seoul and Incheon in fall in 1999. The dry deposition fluxes of PCBs were in the range of $16.7{\sim}62.2ng/m^2/day$. The ambient concentrations of particulate PCBs were in the range of 0.07 to $0.20ng/m^3$. Generally, the mass size distribution of particulate PCBs shows bi-modal distribution. The mass fraction of PCBs in the fine particle fraction ($D_p<2.1 {\mu}m$) was over than 55% of the total PCBs concentrations. It was found that Seoul and Incheon were not the major source of PCBs emissions in Korea. Based on the comparison with the measurement data in summer, 1999, it is likely that both the dry deposition fluxes and ambient particulate PCBs concentrations were not site-specific.

  • PDF

Behavior Evaluation of Aluminium oxide through Measurement of Mass Concentration under Laboratory Environment (연구실 환경에서의 질량농도 측정을 통한 Aluminium oxide의 거동 평가)

  • Park, Jeong-Hwa;Kim, Dong-Hyun;Kim, Jong-Kyu;Kim, Hyung-Sik;Kim, Jeong-Hun
    • Journal of Digital Convergence
    • /
    • v.14 no.3
    • /
    • pp.279-285
    • /
    • 2016
  • With the development of nanotechnology, the amount of nanomaterials increases and the problems of environment and the toxic property associated with it have become a social problem. But regulations and laws of nanomaterials have not yet been established. The purpose of this study is to utilize as the database of safety guidelines for research activities' workers associated with nanomaterials to conduct a behavior evaluation of aluminium oxide, which is most widely used in thirteen kinds of WPMN manufactured nanomaterials in the country. The experiment proceeds in the chamber reduced to 1/6 size of the actual laboratory, the test method was performed in NIOSH 0500. As the results of the study, the mass concentration was in inverse proportion to the particle size of the nanomaterials. And the mass concentration during the operation of ventilation equipment was reduced to about 1/8 times. In the future, it can be utilized as the database of safety guidelines for research activities' workers associated with nanomaterials. However, in order to increase the reliability of the study, the experiment of the mass concentration by particle size and Condensation Particle Counters will be needed additionally.

High Resolution Fine Dust Mass Concentration Calculation Using Two-wavelength Scanning Lidar System (두파장 스캐닝 라이다 시스템을 이용한 고해상도 미세먼지 질량 농도 산출)

  • Noh, Youngmin;Kim, Dukhyun;Choi, Sungchul;Choi, Changgi;Kim, TaeGyeong;Kim, Gahyeong;Shin, Dongho
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_3
    • /
    • pp.1681-1690
    • /
    • 2020
  • A scanning lidar system has been developed. The system has two wavelength observation channels of 532 and 1064 nm and is capable of 360-degree horizontal scanning observation. In addition, an analysis method that can classify the measured particle as an indicator of coarse-mode particle (PM2.5-10) and an indicator of fine-mode particles (PM2.5) and calculate the mass concentration of each has been developed by using the backscatter coefficient at two wavelengths. It was applied to the data calculated by observation. The mass concentrations of PM10 and PM2.5, which showed a distribution of 22-110 ㎍/㎥ and 7-78 ㎍/㎥, respectively, were successfully calculated in the Ulsan Onsan Industrial Complex using the developed scanning lidar system. The analyzed results showed similar values to the mass concentrations measured on the ground around the lidar observation area, and it was confirmed that high concentrations of 80-110 ㎍/㎥ and 60-78 ㎍/㎥ were measured at points discharged from factories, respectively.

Measurement of Atmospheric Dry Deposition and Size Distribution of Particulate PCBs in 1999 at Seoul

  • Park, Seong-Suk;Shin, Hye-Joung;Yi, Seung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.35-43
    • /
    • 2006
  • Ambient particle size distributions of PCBs and their dry deposition fluxes were measured at a site in Seoul to quantify dry deposition fluxes of PCBs and size characteristics of PCBs in the air, and to estimate ambient concentrations of gaseous PCBs and dry deposition fluxes. The dry deposition plate was used to measure dry deposition fluxes of particulate mass and PCBs and a cascade impactor and rotary impactor were used to measure ambient particle size distributions for small ($D_p<9{\mu}m$) and large ($D_p>9{\mu}m$) particles, respectively. Six sample sets were collected from April to July 1999. The fluxes of particulate total PCBs (the sum of 43 congeners) ranged from 160 to $607ng\;m^{-2}day^{-1}$. The size distribution of total PCBs was bimodal with two peaks in small particle size ($D_p{\sim}0.6\;and\;6{\mu}m$, respectively) and, thus, mass concentration being dominant in small particles. The mean particulate PCBs concentration was $6.9{\mu}g$ PCBs/g. The concentrations of PCB homologues in the gas phase were estimated based on the particle/gas partition coefficient ($K_p$) with the measured values of particulate PCBs in this study and they were comparable to those observed in other previous studies. Dry deposition fluxes were estimated by calculating dry deposition velocities.