• 제목/요약/키워드: Particle image analyzer

검색결과 34건 처리시간 0.02초

분무 유동의 입경 계측 기법에 관한 연구 (Measurement Technique of Particle Sizing in Spay Flow)

  • 양창조;김정환;오종환;김만응;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.534-539
    • /
    • 2005
  • Particle image analyzer for measuring droplet size has been developed. Image processing technique was used with relaxation method. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. The measurement results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF

대전된 입자의 영상효과에 의한 필터효율 향상에 관한 실험적 연구 (An Experimental Study on Enhancement of the Filter Efficiency by the Image Effect of Charged Particle)

  • 이창선;정해영;김상수
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.760-768
    • /
    • 2000
  • Filter efficiency of electrically charged particle in uncharged fibrous filter was measured. In previous studies, the effect of charged particle on filter efficiency was investigated but there was difficulty in measuring of image effect that is appeared at the charged small particle. We could easily measure the image effect with charging small particles by photoelectric charging. The spark discharge aerosol generator and a differential mobility analyzer (DMA) were used to generate sub-micron monodisperse particles (${\leq}200$ nm). The generated particles were charged in photoelectric charging process using ultraviolet lamp and electric field. The filter efficiency of the charged particles, classified by another DMA, was measured in filter tester using a condensation nucleus counter (CNC) as function of particle diameter, particle charge and airflow velocity. It is shown that the filter efficiency increases with increasing charge number of the particle and is affected by particle size and flow velocity. Single fiber filter efficiency mainly depends on image force parameter and peclet number. The peclet number was not considered at previous other papers. We propose a modi fied experimental correlation as function of image force parameter and peclet number.

MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구 (Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System)

  • 최해만;문자수명;송정강일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

분무 액적 특성 계측을 위한 디지털 입자 홀로그래피 시스템의 개발 (Development of Digital Particle Holographic System for Measurements of the Characteristics of Spray Droplets)

  • ;강보선
    • 한국분무공학회지
    • /
    • 제15권2호
    • /
    • pp.53-60
    • /
    • 2010
  • This study presents development of digital particle holographic system and its application to spray field to measure three-dimensional velocities and sizes of spray droplets. A double exposure hologram recording system with synchronization system for time control was established and digital holograms can be recorded in a short time interval. To process recorded holograms, the correlation coefficient method was used for focal plane determination of particles. To remove noises and improve the quality of holograms and reconstructed images, the Wiener filter was adopted. The two-threshold and image segmentation methods were used in binary image transformation. For particle pairing, the match probability method was adopted. The developed system was applied to spray field and three-dimensional velocities and sizes of spray droplets were measured. The measurement results of digital holographic system were compared with those made by laser instruments, PDPA(Phase Doppler Particle Analyzer), which proved the feasibility of in-line digital particle holographic system as a good measurement tool for spray droplets.

Image Analysis of Surimi Sol and Gel in Composite System

  • Yoo, Byoung-Seung;Lee, Chong M.
    • Preventive Nutrition and Food Science
    • /
    • 제3권3호
    • /
    • pp.292-294
    • /
    • 1998
  • Surimi sol and gel were prepared by mixing egg albumin, starch, oil and carrageenan, which are used as representative ingredients in the surimi composite, at different ratio. Structural properties in surimi composite were investigated by examining the phase changes and dispersion pattern (average particle size, size range and the averge number of particle) of the particulate ingredients in sol and gel with an image analyzer. A staining technique of the specimen containing egg albumin in surimi gel was developed by adjusting pH of a toluidine staining solution. Image analysis revealed that size and density of ingredient particles were function of the level and dispersion of ingredients except of starch-incorporated surimi gel which showed maximum particle size at 6%.

  • PDF

Nanosolve와 PMMA를 이용한 유용성감초산의 안정화에 대한 연구 (The Study for Stability of Useful Glycyrrhiza uralensis (Licorice Root) Using Nanosolve and PMMA)

  • Ji, Hong-Geun;Kim, Ju-Duck;Kim, Jeong-Dong;Choi, Jung-Sik
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.207-210
    • /
    • 2004
  • 유용성 감초산은 강한 항염 작용으로 주름개선용 기능성 화장품에서 널리 사용되어지는 물질이다. 그러나 용해성이 좋지 않고 빛, 열, 산소에 의하여 변질되기 쉽다. 본 연구에서는 유용성감초산을 PG/hydrogenated lecithin/MCT/glycerine/water를 microfluidzer를 이용해 30-50nm인 nanosolve-licorice를 만들고, 잘 용해된 nanosolve-licorice를 다공성 PMMA에 에탄올과 함께 넣은 후 microfluidzer를 1000 BAR에서 연속 3회 처리하여 안정화시켰다. 이 실험에서 글라블리딘 함량을 HPLC로 측정한 결과 기존의 리포좀에 비하여 3-5배 정도 안정성을 보였으며, PMMA 캡슐로 된 리코러스는 피부의 침투가 기존 리포솜에 비하여 월등히 우수하여 항염 효과를 더욱 증가시켰다. 이러한 실험을 image analyzer, particle size analyzer, FF-TEM, chromameter, HPLC등의 분석장비를 사용하였다.

PDPA계측에 의한 다공 디젤 노즐의 분무 미립화 특성에 관한 연구 (A Study on the Spray Atomization Characteristics of a Multi-Hole Diesel Nozzle using PDPA System)

  • 이지근;오제하;강신재;노병준
    • 한국분무공학회지
    • /
    • 제4권1호
    • /
    • pp.45-54
    • /
    • 1999
  • The spray characteristics of a direct injection multi-hole diesel nozzle having the 2-spring nozzle holder were investigated by using the image processing system and a PDPA(phase Bowler particle analyzer) system. The spray tip penetration, the spray angle, and the droplet diameter and velocity with the variation of the pump speed, injection quantity were measured. From, the experiments, we know that there are small droplets which are not to be detected with spray image around the leading edge of the spray. In order to represent the mean characteristics of the intermittent spray very well, it is very important to set the time windows accurately. From the measurements along the axis of the spray, close to the nozzle, the initially injected droplets are overtaken by droplets that follow them. And also there are the maximum axial mean velocity and SMD at the following part of the leading edge of the spray.

  • PDF

평면 이미지 기법에서 감쇠로 인한 측정 오차에 대한 연구 (Study on Measurement Errors due to Attenuation in Plannar Image technique)

  • 전재영;김동준;고현석;윤영빈
    • 한국분무공학회지
    • /
    • 제7권3호
    • /
    • pp.24-30
    • /
    • 2002
  • In the analysis of the mass distribution and SMD(Sauter Mean Diameter), planar laser imaging technique is a convenient and useful one when compared to the mechanical pattemator or PDPA (Phase Doppler Particle Analyzer). But recorded signals at cameras and intensity of laser are distorted by attenuation. Using experimental datum and assumptions, we study measurement errors due to attenuation in plannar image technique.

  • PDF

SPRAY STRUCTURE OF HIGH PRESSURE GASOLINE INJECTOR IN A GASOLINE DIRECT INJECTION ENGINE

  • Lee, Chang Sik;Chon, Mun Soo;Park, Young Cheol
    • International Journal of Automotive Technology
    • /
    • 제2권4호
    • /
    • pp.165-170
    • /
    • 2001
  • This study is focussed on the investigation of spray characteristics from the high pressure gasoline injector for the application of gasoline direct injection engine. For the analysis of spray structure of high pressure gasoline injector; the laser scattering method with a Nd-Yag laser and the Phase Doppler particle analyzer system were applied to observe the spray development and the measurement of the droplet size and velocity of the spray, respectively. Also spatial velocity distribution of the spray droplet was measured by use of the particle image velocity system. Experimental results show that high pressure gasoline injector shapes the hollow-cone spray, and produce the upward ring shaped vortex on the spray surface region. This upward ring shaped vortex promotes the secondary atomization of fuel droplets and contributes to a uniform distribution of fuel droplets. Most of fuel droplets are distributed under 31$\mu m$ of the mean droplet size (SMD) and the frequency distribution of the droplet size under 25$\mu m$ is over 95% at 7 MPa of injection pressure. According to the experimental results of PIV system, the flow patterns of the droplets velocity distribution in spray region are in good agreement with the spray macroscopic behaviors obtained from the visualization investigation.

  • PDF