• Title/Summary/Keyword: Particle density

Search Result 1,492, Processing Time 0.028 seconds

High Density Crowd Simulation based on SPH (Smoothed Particle Hydrodynamics 기반 고 밀집 군중 시뮬레이션 기법)

  • Kang, Shin-Jin;Lee, Jung;Kim, Soo-Kyun
    • Journal of Korea Game Society
    • /
    • v.11 no.6
    • /
    • pp.193-199
    • /
    • 2011
  • Producing high density crowd simulation is time-consuming task as increasing the number of individuals in the crowds. In this paper, we propose a new control technique that can create realistic high density crowd simulation by using Smoothed Particle Hydrodynamics (SPH) method from fluid simulation field. Equations in SPH method are modified for evacuation, distance maintenance, and group maintenance forces for individual behaviors in the crowds. Experimental results showed that the proposed system could enable natural high density crowd simulation efficiently.

DETAILED EXAMINATION OF INVERSE-ANALYSIS PARAMETERS FOR PARTICLE TRAPPING IN SINGLE CHANNEL DIESEL PARTICULATE FILTER

  • Jung, S.C.;Park, J.S.;Yoon, W.S.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.165-177
    • /
    • 2007
  • Predictions of diesel particulate filtration are typically made by modeling of a particle collection, and providing particle trapping levels in terms of a pressure drop. In the present study, a series of single channel diesel particulate filter (DPF) experiments are conducted, the pressure traces are inversely analyzed and essential filtration parameters are deducted for model closure. A DPF filtration model is formulated with a non-linear description of soot cake regression. Dependence of soot cake porosity, packing density, permeability, and soot density in filter walls on convective-diffusive particle transportation is examined. Sensitivity analysis was conducted on model parameters, relevant to the mode of transition. Soot cake porosity and soot packing density show low degrees of dispersion with respect to the Peclet number and have asymptotes at 0.97 and $70\;kg/m^3$, respectively, at high Peclet number. Soot density in the filter wall, which is inversely proportional to filter wall Peclet number, controls the filtration mode transition but exerts no influence on termination pressure drop. The percolation constant greatly alters the extent of pressure drop, but is insensitive to volumetric flow rate or temperature of exhaust gas at fixed operation mode.

Development of Tungsten CMP (Chemical Mechanical Planarization) Slurry using New Abrasive Particle (새로운 연마입자를 이용한 텅스텐 슬러리 개발)

  • Yu, Young-Sam;Kang, Young-Jae;Kim, In-Kwon;Hong, Yi-Koan;Park, Jin-Goo;Jung, Seok-Jo;Byun, Jung-Hwan;Kim, Moon-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.571-572
    • /
    • 2006
  • Tungsten CMP needs interconnect of semiconductor device ULSI chip and metal plug formation, CMP technology is essential indispensable method for local planarization. This Slurry development also for tungsten CMP is important, slurry of metal wiring material that is used present is depending real condition abroad. It is target that this research makes slurry of efficiency that overmatch slurry that is such than existing because focus and use colloidal silica by abrasive particle to internal production technology development. Compared selectivity of slurry that is developed with competitor slurry using 8" tungsten wafer and 8" oxide wafer in this experiment. And removal rate measures about density change of $H_2O_2$ and Fe particle. Also, corrosion potential and current density measure about Fe ion and Fe particle. As a result, selectivity find 83:1, and expressed similar removal rate and corrosion potential and current density value comparing with competitor slurry.

  • PDF

Visualizing test on the pass-through and collision characteristics of coarse particles in a double blade pump

  • Tan, Minggao;Lian, Yichao;Liu, Houlin;Wu, Xianfang;Ding, Rong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • As the key equipment in deep ocean mining, the slurry pump suffers from wear and blocking problems. In this paper, high-speed photography technique is applied to track the movement rule of single particle of the coarse particle solid-liquid two-phase flow in a double blade slurry pump. The influences of particle diameter and particle density on the pass-through and collision characteristics of particles are analyzed as well. The results show that the average of the passing pump time first decreases and then increases when the particle diameter increases. The average of the passing pump time decreases by 22.7%, when the particle density increases from $1.09g/cm^3$ to $1.75g/cm^3$. Besides, the particle density has great influence on the location where the particle hits the tongue. Most particles of $1.09g/cm^3$ hit the tongue on the left side, while collision location of particles of $1.75g/cm^3$ is mainly on the top and at the right side of the tongue. The research can provide a basis for the optimization design of slurry pump in deep ocean mining system.

Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

Real-Time Motion Estimation Algorithm for Mobile Surveillance Robot (모바일 감시 로봇을 위한 실시간 움직임 추정 알고리즘)

  • Han, Cheol-Hoon;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.3
    • /
    • pp.311-316
    • /
    • 2009
  • This paper presents the motion estimation algorithm on real-time for mobile surveillance robot using particle filter. the particle filter that based on the monte carlo's sampling method, use bayesian conditional probability model which having prior distribution probability and posterior distribution probability. However, the initial probability density was set to define randomly in the most of particle filter. In this paper, we find first the initial probability density using Sum of Absolute Difference(SAD). and we applied it in the partical filter. In result, more robust real-time estimation and tracking system on the randomly moving object was realized in the mobile surveillance robot environments.

A Study on the Soot Particle Measurement in Co-Flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple (레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구)

  • Han, Yong-Taek;Lee, Ki-Hyng;Lee, Won-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.863-870
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame has been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distribution in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by particles. A laser extinction method was used to measure the soot volume fraction and laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

A Study on the Soot Particle Measurement in Co-flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple (레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구)

  • Han, Yong-Taek;Lee, Ki-Hyung;Lee, Won-Nam
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1267-1273
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame have been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles were detected were detected by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by absorbing particles. A laser extinction method was used to measure the soot volume fraction and Laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

  • PDF

Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon (광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성)

  • Choi, B.C.;Iwasaka, Y.;Lim, J.C.;Jeong, S.B.;Kim, Y.S.;Dmitri, T.;Nagatani, T.;Yamada, M.;Kim, S.B.;Hong, G.M.;Lee, Y.G.;Yoo, H.J.
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

Effects of Feed Particle Size, Stocking Density, and Dissolved Oxygen Concentration on the Growth of Olive Flounder Paralichthys olivaceus (배합사료의 크기, 사육밀도 및 용존산소 농도가 넙치(Paralichthys olivaceus)의 성장에 미치는 영향)

  • Kim, Sung-Sam;Lee, Jin-Hyuck;Kim, Kang-Woong;Kim, Kyoung-Duck;Lee, Bong-Joo;Lee, Kyeong-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.3
    • /
    • pp.314-321
    • /
    • 2015
  • We performed three sets of feeding trials to establish the optimal feed size (Exp-I), stocking density (Exp-II), and dissolved oxygen level (DO) (Exp-III) for olive flounder Paralichthys olivaceus. In Exp-1, four replicate groups of fish ($53.6{\pm}0.9g$) were fed commercial diets with three particle sizes (small, medium, and large). In Exp-II, fish ($30.0{\pm}0.1g$) were reared at four stocking densities (1.8, 3.5, 5.3, and $7.1kg/m^3$). In Exp-III, fish ($187{\pm}1.48g$) were reared under two different DO levels (2-3 and 6-7 mg/L). In Exp-I, fish fed the large-particle diet gained significantly more weight and had a lower feed conversion ratio than fish fed the small- and medium-particle diets. In Exp-II, fish reared at 1.8 and $3.5kg/m^3$ gained slightly more weight and had lower feed conversion ratios than fish reared at 5.3 and $7.1kg/m^3$, although these differences were not significant. In Exp-III, negative effects were observed in the low DO groups. Therefore, under our experimental conditions, the optimal feed particle size, stocking density, and DO level for olive flounder were 9-9.4 mm, $3.5kg/m^3$, and 6-7 mg/L, respectively.