• 제목/요약/키워드: Particle Volume Concentration

검색결과 198건 처리시간 0.053초

커먼레일 직접분사식 디젤엔진에서 시분해 레이저 유도 백열법을 이용한 매연입자의 배출 특성 (The Characteristics of Exhausted Soot Particles from a Common-Rail Direct Injection Diesel Engine by TIRE-LII)

  • 김규보;한휘영;장영준;전충환
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.78-85
    • /
    • 2007
  • Recently, diesel vehicles have been increased and their emission standards have been getting strict. The emission of diesel vehicles contains numerous dangerous compounds, especially particulate matters cause a serious environmental pollutant and affect to human health seriously. Thousands of studies have already reported that particulate matters are associated with respiratory and cardiovascular diseases, and death. Due to these, it is necessary to measure the soot concentration and soot particle size in laboratory flames or practical engines to recognize the soot formation, and develop the control strategies for soot emission. In this study, the characteristics of exhausted soot particle size and volume fraction from 2.0L CRDI diesel engine have been investigated as varying engine speed and load. Laser induced incandescence has been used to measure soot concentration. Time-resolved laser induced incandescence has been used to determine soot particle size in the engine. The soot volume fraction is increased as increasing engine load but soot volume fraction is decreased as increasing engine speed. The primary particle size is distributed about $35nm{\sim}60nm$ at each experimental conditions.

부유분진중 다환방향족 탄화수소에 관한 연구 - 서울 흑석동 지역을 중심으로 (A Study on Polynucler Aromatic Hydrocarbons in Atmospheric Particulate Matters -Based on the data aquired in Heukseok-Dong, Seoul-)

  • 손동헌;이규식;허문영
    • 약학회지
    • /
    • 제30권6호
    • /
    • pp.323-328
    • /
    • 1986
  • This paper describes on the distribution of polynuclear aromatic hydrocarbons (PAHs) in various size of atmospheric particulate matter (A.P.M.). A.P.M. in Seoul city were collected on guartz fiber filter according to particle size using an Andersen high volume air sampler from Feb. 1983 to March 1984. And 7 PAHs [benzo(a)pyrene, benzo(k)fluoranthene, benzo(ghi)perylene, benzo(e) pyrene, perylene, chrysene, and pyrene] were analyzed by high performance liquid chromatography. The concentration of A.P.M. showed spring-winter maxima and summer-autumn minia. The A.P.M. was lowest in the concentration at the 1.1~3.3$\mu\textrm{m}$ particulates, and the concentration increased as the particle size increased or decreased. But the concentrations of PAHs increased with the decrease in the particle size, and were predominant in winter. The correlations among the PAHs were high. And there fore, benzo(a)pyrene concentration could be considered as the representive of PAHs.

  • PDF

익산시의 부유먼지에 관한 연구 (Studies on the Total Suspended Particulates in Iksan City.)

  • 전병영
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

폐굴껍질에 의한 합성폐수 중의 인 제거 (Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells)

  • 정경훈;정오진;최형일
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

FLUID-GRANULE MIXED FLOIW DOWNSTREAM OF SCOUR HOLE AT OUTLET OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Shim, Myung-Pil;Kim, Kyung-Sub
    • Water Engineering Research
    • /
    • 제3권3호
    • /
    • pp.155-162
    • /
    • 2002
  • This study presents the theoretical approach for volume concentration, velocity profile, and granular discharge on the fluid-granule mixed flow downstream of the scour hole at the outlet of the hydraulic structure. Concept of dilatant model was applied for the stress-strain relationships of fluid-granule mixed flow since the flow downstream of the scour hole corresponds to debris flow, where momentum transfers through particle collisions. Mathematical formulations were derived using momentum equation and stress-strain relation of the fluid-granule mixture. Velocity profile under the assumption of uniform concentration over flowing layer showed the downward convex type. Deposition angle of downstream hump was found to be a function of an upstream slope angle, a dynamic friction angle and a volume concentration irrespective of flow itself, Granular discharge and the overflow depth were obtained with given values of inflow rates. Experimental results showed relatively good agreements with theoretical ones.

  • PDF

제한된 공간내 분무의 유동특성 실험 (Experimental Study on the Flow Characteristic of a Confined Ppray)

  • 정선재;이상용
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.1011-1018
    • /
    • 1992
  • A series of experiment has been performed on the spray characteristics in a cylindrical confined space with the injection pressure taken as a parameter. By using a single-hole patternator and the Malvern particle sizer, the spray mass flux, drop size and volume concentration distributions along the radial and axial directions were obtained ; the line-of- sight data by Malvern particle sizer have been converted to the ring-of-sight data by using the tomographical transformation techniqe. The experimental results show that, due to the restriction on the ambient gas entrainment by the wall boundary, the effective spray angle is increasing. The spray drops were measured to be smaller in the confined space because of a large number of floating small drops by recirculation of the gas phase and the breakup of large drops by the wall collision. Also the details on the flow behavior of the confined spray are discussed.

침강탄산칼슘제조건과 그 입자도에 관한 연구 (Studies on the relationship of the preparation and the particle size of the precipitated calcium carbonate)

  • 나운룡
    • 약학회지
    • /
    • 제12권3_4호
    • /
    • pp.41-49
    • /
    • 1968
  • The optimum reaction conditions for the preparation of the precipitated calcium carbonate of an average particle size of 0.05.mu. in diameter was set in which the Box-Wilson Plan was applied. The reaction conditions are as follows; 1) concentration of milk of lime; 6.56% w/w 2) temperature; 14.24.deg. C #) velocity of carbon dioxide introducing; 1.95l/min. The crystal form was found that of calcite in X-ray diffraction analysis. The particle size was determined by the sedimentation volume measurement. The shape was identified by the elctron micro-diffraction pattern and the electron microscopic photographs.

  • PDF

경구용 항원 수송체 모델로서 폴리락티드-글리콜리드 마이크로스피어의 입자도 조절 (Particle Size Control of Poly(Lactide-co-Glycolide) Microspheres for Oral Antigen Delivery Systems)

  • 송일용;송세현;송우헌;조성완;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권4호
    • /
    • pp.315-321
    • /
    • 1999
  • Poly (lactide-co-glycolide) (PLGA) microspheres containing ovalbumin (OVA) as a model protein drug were prepared by double emulsification method, and various conditions such as mixing rate, volume of outer phase and isopropyl alcohol concentration in outer phase during secondary emulsification were observed to control the size of microspheres. In addition, entrapment efficiency of OVA and protein denaturation were also evaluated. As the rate of stirring was increased, the size of particles was decreased. But excessive stirring increased the particle size of microspheres. In a preparation condition of small volume of outer phase, the particle size was decreased but the entrapment efficiency was increased. Adding isopropyl alcohol to outer phase decreased the size of particles, but increased the entrapment efficiency. Microparticles should have smaller size than $10\;{\mu}m$ to be uptaked by Peyer's patch in small intestine. High speed of mixing and relatively small volume of outer phase are needed to reduce the size. In addition, appropriate amount of isopropyl alcohol in outer phase also plays an important role in size reduction of PLGA microspheres.

  • PDF

ICP법에 의한 도시대기중 중금속 농도 측정: 중앙대학교를 중심으로 (Determination of Heavy Metals Concentrations in Urban Air using ICP Method : in the Area of Chung-Ang University)

  • 손동헌;신혜숙;정성윤;정원태
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.222-229
    • /
    • 1993
  • Total suspended particles in the atmosphere were collected on the quartz fiber filters using an ANdersen Hi-volume air sampler from March 1989 to October 1989 and from June 1990 to February 1991, at Chung-Ang University in Seoul. A total amount of eight heavy metals (Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) in total suspended particles were determined by ICP spectrophotometer. The annual arithmetic mean concentration of total suspended particle was 162.3$\mug/m^3$ and eight metals(Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) were 11.6, 609.2, 3.5, 337.1, 2739.5, 15.1, 89.4 and 100.5ng/$m^3$, respectively. The concentration of total suspended particle was highest in the spring(343.7$\mug/m^3$) and lowest in the summer(91.8$\mug/m^3$). These heavy metals were distinguished into two groups in terms of their particle size distribution. The contents of first-group heavy metals (Fe, Ti, Mn) were increased in accordance with the growth of the particle size. The contents of the second-group ones such as Pb, Cd, V, and Zn, on the contrary, came to increase according as the particle size reduced. Statistical analysis indicated that there was a correlation between total suspended particle and Fe in coarse particles, and between total Suspended Particle and Zn, Pb in fine particle.

  • PDF

복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과 (Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol)

  • 김기연;김치년;김윤신;노영만;이철민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.