• Title/Summary/Keyword: Particle Seeding

Search Result 49, Processing Time 0.027 seconds

Effect of Particle Size and Velocity Ratio on the Flow Mixing Characteristics in the Secondary Combustor (덕티드 로켓의 이차 연소기 내에서 입자의 크기와 속도비가 유동 혼합에 미치는 영향)

  • Park, Jung Shin;Park, Soon Sang;Han, Doo-Hee;Shin, Jun-Su;Sung, Hong-Gye;Kwak, Jae Su;Choi, Ho-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, the effect of velocity ratio and particle size on the flow mixing characteristics in the secondary combustor was investigated. Both PIV(Particle Image Velocimetry) technique and LES(Large Eddy Simulation) were applied. Two sizes of Polystyrene PIV seeding particle of 5 and $50{\mu}m$, and three velocity ratios of 5, 3, and 1.5 were considered. Results showed that the mixing of two air streams created reattachment and recirculation regions. The size of the recirculation region was decreased as the velocity ratio increased. For the larger particle cases, due to the increased momentum by the larger particles, the size of the recirculating regions were larger than that of the smaller particle cases and the effect of the velocity ratio was not as significant as in the smaller particle case.

Modulated LII technique for the Measurement of Flow Velocity in Laminar Flames (층류화염 유동속도 측정을 위한 modulated LII 기법)

  • Lee, Won-Nam;Lee, Jung-Soo;Nam, Youn-Woo
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.3
    • /
    • pp.36-43
    • /
    • 2006
  • The modulated LII technique has been suggested for the measurement of axial velocity profiles of laminar diffusion flames. The theoretical background is explained based on the blackbody radiation and LII signal. Experimentally, soot particles in ethylene diffusion flames are heated by a modulated Ar-ion laser beam. LII signals and their phase angles are measured using a lock-in amplifier at the different flame heights and the axial flow velocities are obtained from the measured phase angle delay informations. The measured velocities are similar to those from LDV measurements under the same operating conditions. The effects of laser power, LII signal wavelength, and modulation frequencies are not sensitive to the velocity measurement. However, the choice of an optical chopper blade type could affect the measurement result. The use of a 6/5 chopper blade showed the better result that is. possibly due to the square shape of modulated laser beam. This study successfully demonstrated that axial flow velocities of laminar diffusion flames can be measured by a new technique utilizing LII signal, which does not need particle seeding unlikely to LDV or PIV techniques.

  • PDF

A Study on the Development of Measurement Techniques for Thermal Flows in MEMS

  • Ko Han-Seo;Yang Sang-Sik;Yoo Jai-Suk;Kim Hyun-Jung
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.387-395
    • /
    • 2006
  • A review on advanced flow visualization techniques is presented particularly for applications to micro scale heat and mass transport measurements. Challenges, development and applications of micro scale visualization techniques are discussed for the study of heating/evaporating thin films, a heated micro channel, and a thermopneumatic micro pump. The developed methods are (1) Molecular Tagging Fluorescence Velocimetry (MTFV) using 10-nm caged seeding molecules (2) Micro Particle Velocimetry (MPIV) and (3) Ratiometric Laser Induced Fluorescence (LIF) for micro-resolution thermometry. These three methods are totally non-intrusive techniques and would be useful to investigate the temperature and flow characteristics in MEMS. Each of these techniques is discussed in three-fold: (1) its operating principle and operation, (2) its application and measurement results, and (3) its future challenges.

Novel room temperature grown carbon based cathodes for field emission using diamond nano-particle seeding technique

  • Satyanarayana, B.S.;Hiraki, A.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.448-454
    • /
    • 2001
  • Low field electron emission from novel carbon based cold cathodes is reported. The cathodes consisted of a layer of nanoseeded diamond and an over layer of nanocluster carbon films. The nanoseeded diamond was first coated on to thesubstrate. The nanocluster carbon films were then deposited on the nanocrystalline diamond coated substrates using the cathodic arc process at room temperature. The heterostructured microcathodes were observed to exhibit electron emission currents of 1 $\mu$A/cm$^2$ at fields as low as 1.5 to 2V/$\mu$m. The effect of the nanoseeded diamond size and concentration and the properties of different nanocluster carbon films on emission characteristics is presented.

  • PDF

Patterning of CVD Diamond Films For MEMS Application

  • Wang, Xiaodong;Yang, Yirong;Ren, Congxin;Mao, Minyao;Wang, Weiyuan
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.167-170
    • /
    • 1998
  • To apply diamond films in microelectromechanical systems(MEMS), it is necessary to develop the patterning technologies of diamond films in the micrometer scale. In this paper, three different kinds of technologies for patterning CVD diamond films carried out by us were demonstrated: selective growth by improved diamond nucleation in DC bias-enhanced microwave plasma chemical vapor deposition (MPCVD) system, selective growth of seeding using diamond-particle-mixed photoresist, and selective etching of oxygen ion beam using Al as the mask. It was show that high selectivity and precise patterns had been achieved, and all the processes were compatible with IC process.

  • PDF

Echo-PIV: in vivo Flow Measurement Technique (에코 PIV: in vivo 유동 측정기법)

  • kim Hyoung-Bum;Hertzberg Jean;Shandas Robin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.26-35
    • /
    • 2005
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) method has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window of offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow and pulsatile flow showed good agreement with both optical PIV measurements and the known analytic solution. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

  • PDF

Development of PIV System by Image Board (이미지 보오드를 이용한 PIV시스템의 개발)

  • Cho, Dae-Hwan;Choi, Jang-Un;Doh, Deok-Hui;Lee, Yeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.30-38
    • /
    • 1996
  • A PIV system consisting of an image board slit into personal computer and 2-D sheet light projector is developed and related techniques to improve its performance are discussed. A grey-level cross correlation method capable of overcoming particle seeding limitation is suggested. And a sub-pixed interpolation method in determining the vector terminal is preposed by considering 8-neighbours correlation distributing patterns. Furthermore, pressure estimation from the acquired velocity vectors by applying the Poisson equation is persented with reasonable feasibility. As a practical application of the present system, evaporator flows are analysed and attained instantaneous velocity vectors reveal that the flow phenomena maintain turbulent fluctuation.

  • PDF

Development of Echo PIV Using Ultrasound Contrast Agent (초음파 조영제를 애용한 Echo PIV 기법의 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

Solvothermal Synthesis of α-Al2O3 from Boehmite with Seeding Technique

  • Jo, Hye Youn;Park, Min-Gyeong;Lee, Seung-Ho;Kim, Dae Sung;Lee, Young Kwan;Lim, Hyung Mi
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.273-278
    • /
    • 2015
  • ${\alpha}-Al_2O_3$ was synthesized by solvothermal synthesis using ${\alpha}-Al_2O_3$ seed, precursor of fine boehmite (Al(OOH)) or gibbsite ($Al(OH)_3$), and 1, 4-butanediol solvent. The seed content and precursor type were selected as variables in order to synthesize ${\alpha}-Al_2O_3$. The formation time of ${\alpha}-Al_2O_3$ was reduced and the size of the particles was decreased with addition of the seed. When the seed content was increased, the size of the synthesized ${\alpha}-Al_2O_3$ was reduced. Morphologies of the as-synthesized ${\alpha}-Al_2O_3$ with ${\alpha}-Al_2O_3$ seed were polyhedron-shaped, while the shape was plate-like or polyhedral without the seed, depending on the additives or the average particle size of the boehmite precursor. The aggregation of as-synthesized ${\alpha}-Al_2O_3$ from boehmite was smaller than that from gibbsite. As-synthesized ${\alpha}-Al_2O_3$, with 140 nm size, was obtained by using the seed and boehmite precursor.

Crystal growing of sodium type 13X zeolite by continuous crystallization method (연속결정화 방법에 의한 13X 제올라이트 결정성장)

  • 김익진;이해진;서동남
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.4
    • /
    • pp.190-195
    • /
    • 2002
  • NaX zeolite crystals of a uniform particle size of 50 $\mu$m were grown by continuous crystallization method from seed crystals (10~20 $\mu$m) added into a 0.5~2.0 g mother liquor having a composition $3.5Na_2O : Al_2O_3: 2.1SiO_2: 1000H_2O$. In order to investigate the crystal growing by continuous method, the mother solution was supplied after 7 days, 5 days, 3 days and 1 day, respectively. The seeding resulted in an increase in the fraction of large crystals compared with unseeded batches and successfully led to an uniform NaX zeolite crystal. It was postulated that the seeding in the synthesis mixture leaded out increase of surface area for physical contact reaction and directed growth of seed crystal without the nucleation in the synthesis gel.