• Title/Summary/Keyword: Particle Image velocimetry

Search Result 642, Processing Time 0.023 seconds

Measurements of Plasma Flows in Micro-Tube/Channel Using Micro-PIV (Micro-PIV를 이용한 마이크로 튜브/채널 내에서의 혈장유동측정)

  • Ko, Choon-Sik;Yoon, Sang-Youl;Ki, Ho-Seong;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.587-593
    • /
    • 2004
  • In this paper, flow characteristics of plasma flow in a micro-tube were investigated experimentally using micro particle image velocimetry(micro-PIV). For comparison, the experiments were repeated for deionized(DI) wale. instead of plasma. Both velocity profiles of plasma and do-ionized water are well agreed with the theoretical velocity distribution of newtonian fluid. We also carried out generating plasma-in-oil droplet formation at a Y-junction microchannel. In order to clarify the hydrodynamic aspects involved in plasma droplet formation, Rhodamine-B were mixed with plasma only for visualization of plasma droplet. With oil as the continuous phase and plasma as the dispersed phase, plasma droplet can be generated in a continuous phase flow at a Y-junction. For given experimental parameters, regular-sized droplets are reproducibly formed at a uniform flow conditions.

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1475-1478
    • /
    • 2008
  • We have investigated the blood sucking phenomena of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism and eventually to develop a bio-mimic technology that can be used to resolve the problem encountered in the transport of infinitesimal biological fluids in various bio-chips and microchips. At first, the consecutive velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) system employed with a high-speed camera. The velocity signals of the blood-sucking flow in the proboscis represent a periodic pulsatile flow pattern and spectral analysis on the velocity waveform shows a clear peak at 6.1 Hz.

  • PDF

Development of Echo PIV Using Ultrasound Contrast Agent (초음파 조영제를 애용한 Echo PIV 기법의 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

Flow Behavior in a Rectangular Tunnel Opened and Closed at Both Sides Using CFD

  • Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.368-377
    • /
    • 2012
  • Most tunnel simulations have been focused on the thermal field and the critical velocity for suppression of hot back-layering flow in case of fire and on the characteristics of a tunnel fire in terms of the flame propagation and the toxic gas generation. In this paper, a comparative study of the flow characteristics of polluted air with no heat source in a tunnel model opened and closed at both end sides is implemented into a recognized CFD simulation code. The model is used to investigate the flow characteristics depending on the three different Reynolds numbers of 640, 1270 and 2120, which have been chosen by the flow velocities of 0.3, 0.6 and 1.0 m/s through the inlet. The results of this study have shown that the CFD predictive and experimental approaches are available in qualitatively studying the correlation of flow behaviors for a better tunnel design.

Flow Field Analysis of Smoke in a Rectangular Tunnel

  • Lee, Yong-Ho;Park, Sang-Kyoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.679-685
    • /
    • 2009
  • In order to simulate a smoke or poisonous gas emergency in a rectangular tunnel and to investigate a better way to exhaust the smoke, the characteristics of smoke flow have been analyzed using flow field data acquired by Particle Image Velocimetry(PIV). Olive oil has been used as tracer particles with the kinematic viscosity of air, $1.51{\times}10^{-5}\;m^2/s$. The investigation has done in the range of Reynolds number of 1600 to 5333 due to the inlet velocities of 0.3 m/s to 1 m/s respectively. The average velocity vector and instantaneous kinematic energy fields with respect to the three different Reynolds numbers are comparatively discussed by the Flow Manager. In general, the smoke flow becomes more disorderly and turbulent with the increase of Reynolds number. Kinematic energy in the measured region increases with the increase of Reynolds number while decreasing at the leeward direction about the outlet region.

Basic flow fields and stability characteristics of two dimensional V flames (이차원 V 화염의 기본 유동장과 안정화 특성)

  • Park, Jang-Hee;Lee, Dae-Keun;Shin, Hyun-Dong;Kim, Moon-Uhn
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.185-193
    • /
    • 2003
  • Basic flow fields of two dimensional V flames were examined as a preliminary work to study the instability of premixed flame with vorticity generation. Laminar premixed propane and methane flame were anchored by electrically heated wire to make two dimensional V flames. Flow fields were measured mainly by PIV(Particle Image Velocimetray) and the results were compared with those obtained by LDV(Laser Doppler Velocimetry) to confirm their reliability. Because the curvatures of V flames are so small, V flames were locally assumed to be inclined planar flames in gravitational field. The measured flow fields were locally compared with those of analytical solutions, which showed the qualitatively similar results. In downstream region, the vorticity fields were nearly constant except region near the center line, which support the assumption of locally one dimensional flame. Besides it was tried to find experimentally the similarity of flow fields in downstream region. Finally, stability diagram of propane and methane flames were drawn for the equivalence ratio less than one and the wide range of mean velocity.

  • PDF

Simultaneous PIV/OH PLIF Measurements in Hydrogen Nonpremixed Flames with Coaxial Air (PIV/OH PLIF 동시 측정을 이용한 동축공기 수소확산화염의 실험적 연구)

  • Kim, Mun-Ki;Kim, Seung-Han;Yoon, Young-Bin
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.115-123
    • /
    • 2003
  • Simultaneous measurements of velocity and OH distribution were made using particle image velocimetry(PIV) and planar laser-induced fluorescence(PLIF) of OH radical in turbulent hydrogen nonpremixed flames with coaxial air. The OH radical was used as an approximate indicator of chemical reaction zone. The OH layer was correlated well with the stoichiometric velocity, $U_s$, instantaneously and on average. In addition, high strain-rate regions almost coincide with the OH distribution. The residence time in flame surface, calculated from the root-mean-square value of the radial velocity, is proportional to $(x/d_F)^{0.7}$. It is found that the mean value of principal strain rate on the OH layer can be scaled with $(x/d_F)^{-0.7}$ and therefore, the product of the residence time and the mean strain rate remains constant over all axial positions.

  • PDF

Characteristics on the Thermal and Fluid Flow in the Rectangular Aquarium Basin by Using PIV (PIV를 이용한 사각수조 내의 온도와 유체 유동 특성)

  • Kim, B.H.;Konar, Dibyendu;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.31-38
    • /
    • 2005
  • 육상 수조식 양식장은 해수를 끌어들여 어류를 기르는 데 사용된다. 본 연구는 사각 수조 내의 다양한 기하학적 관계와 유동에 대한 유동 특성을 도출하였다. 수치해석은 유한 체적법과 SIMPLE 기수법은 수치해석법을 활용하였으며, 비압축성 유체와 3차원 표준 $k-{\varepsilon}$난류 모델을 적용하였다. 속도 분포, 온도 분포에 대한 정보를 확보하였다. 실험과 수치해석의 결과가 정성적으로 잘 일치함을 보였다. 양식장의 깊이가 증가함에 따라 바닥 쪽의 유동이 더욱 안정됨을 확인하였다. 이는 각종 배설물 등의 정체현상으로 연결될 수 있음을 확인하였다. 수조내의 온도는 유입구의 초기 온도가 중요하며, Re 수가 증가할수록 온도는 상승하고 유입구의 반대 벽면 근처의 온도가 유입구 보다 증가함을 알 수 있었다.

  • PDF

Three-dimensional vortex structure near a corner of a translating plate (병진운동하는 평판의 모서리에서의 3차원 와류 구조 가시화)

  • Kim, Daegyoum
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.21-25
    • /
    • 2015
  • Three-dimensional vortex structures in the corner region of translating normal plates are visualized experimentally with defocusing digital particle image velocimetry. Vortex formation processes for three plates with corner angle $60^{\circ}$, $90^{\circ}$, and $120^{\circ}$ are compared in order to study the effect of corner shape on vortex formation. In all cases, the self-induction of the starting vortex and its interaction with the potential flow induced by the moving plate cause the vortex to change its form dynamically after the plate starts to translate. While the vortex near a corner follows the plate in the low corner angle of $60^{\circ}$, the vortex separates early from the plate and its forward motion becomes slow in the high corner angle of $120^{\circ}$. It is also found that the starting vortex can transport inward at the corner, which depends on the corner angle.

Dynamic PIV Measurement of Swirl Flow in a PC Fan

  • ARAMAKI Shinichiro;HAYAMI Hiroshi
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.41-45
    • /
    • 2004
  • The dynamic particle image velocimetry (PIV) is consisted of a high frequency pulse laser, high speed cameras and a timing controller. The three velocity components of flow downstream of an axial flow fan for PC cooling system are measured using the dynamic PIV system. An Axial flow fan has seven blades of 72 mm in diameter. The rotating speed is 1800 rpm. The downstream flow is visualized by smoke particles of about $0.3-1\;{\mu}m$ in diameter. The three-dimensional instantaneous velocity fields are measured at three downstream planes. The swirl velocity component was diffused downstream and the change in time-mean vorticity distribution downstream was also discussed. The spatio-temporal change in axial velocity component with the blades passing is recognized by the instantaneous vector maps. And the dynamic behavior of vorticity moving with the rotating blades is discussed using the unsteady vorticity maps.

  • PDF