• Title/Summary/Keyword: Particle Image Velocity

Search Result 472, Processing Time 0.033 seconds

A Study on the Improvement of PIV Performance (PIV의 성능개선에 관한 연구)

  • 이영호;김춘식;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.34-42
    • /
    • 1994
  • The present study is aimed to improve the PIV performance by suggesting a two-frame particle identification technique and by introducing estimation method of wall pressure distribution from the velocity data. Adopted image processing system consists of one commercial image board slit into a personal computer, 2-D sheet light generator, flow picture recording apparatus and related particle identification software. A revised particle tracking method essential to PIV performance is obtained by particle centroid correlation pairing (CCP) and its effectiveness is ascertained by comparison with multi-frame identification.

  • PDF

Identification of Factors Affecting Errors of Velocity Calculation on Application of MLSPIV and Analysys of its Errors through Labortory Experiment (MLSPIV를 이용한 유속산정시 오차요인 규명 및 실내실험을 통한 유속산정오차 분석)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.153-165
    • /
    • 2010
  • Large-Scale Particle Image Velocimetry (LSPIV) is an extension of particle image velocimetry (PIV) for measurement of flows spanning large areas in laboratory or field conditions. LSPIV is composed of six elements - seeding, illumination, recording, image transformation, image processing, postprocessing - based on PIV. Possible error elements at each step of Mobile LSPIV (MLSPIV), which is a mobile version of LSPIV, in field applications are identified and summarized the effect of the errors which were quantified in the previous studies. The total number of elemental errors is 27, and five error sources were evaluated previously, seven elemental errors are not effective to the current MLSPIV system. Among 15 elemental errors, four errors - sampling time, image resolution, tracer, and wind - are investigated through an experiment at a laboratory to figure out how those errors affect to velocity calculation. The analysis to figure out the effect of the number of images used for image processing on the velocity calculation error shows that if over 50 images or more are used, the error due to it goes below 1 %. The effect of the image resolution on velocity calculation was investigated through various image resolution using digital camera. Low resolution image set made 3 % of velocity calculation error comparing with high resolution image set as a reference. For the effect of tracers and wind, the wind effect on tracer is decreasing remarkably with increasing the flume bulk velocity. To minimize the velocity evaluation error due to wind, tracers with high specific gravity is favorable.

A study on a development of a measurement technique for diffusion of oil spill in the ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;김기철;강신영;도덕희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;강신영;도덕희;김기철
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Measurement of the Slurry Flow-Field during Chemical Mechanical Polishing (Particle Image Velocimetry 기법을 이용하여, Chemical Mechanical Polishing 공정시 Slurry 유동장 측정)

  • Shin, Sang-Hee;Kim, Mun-Ki;Koh, Young-Ho;Kim, Ho-Young;Lee, Jae-Dong;Hong, Chang-Ki;Yoon, Young-Bin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) in semiconductor production is characterized its output property by Removal Rate(RR) and Non-Uniformity(NU). Some Previous works shows that RR is determined by production of pressure and velocity and NC is also largely affected by velocity of flow-field during CMP. This study is about the direct measurement of velocity of slurry during CMP and reconstruction whole flow-field by Particle Image Velocimetry(PIV) Techniques. Typical PIV system is tuned adequately for inspecting CMP and Slurry Flow-field is measured by changing both Pad RPM and Carrier RPM. The results show that velocity is majorly determined not by Carrier RPM, but by Pad RPM.

  • PDF

Particle image velocimetry measurement of complex flow structures in the diffuser and spherical casing of a reactor coolant pump

  • Zhang, Yongchao;Yang, Minguan;Ni, Dan;Zhang, Ning;Gao, Bo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.368-378
    • /
    • 2018
  • Understanding of turbulent flow in the reactor coolant pump (RCP) is a premise of the optimal design of the RCP. Flow structures in the RCP, in view of the specially devised spherical casing, are more complicated than those associated with conventional pumps. Hitherto, knowledge of the flow characteristics of the RCP has been far from sufficient. Research into the nonintrusive measurement of the internal flow of the RCP has rarely been reported. In the present study, flow measurement using particle image velocimetry is implemented to reveal flow features of the RCP model. Velocity and vorticity distributions in the diffuser and spherical casing are obtained. The results illuminate the complexity of the flows in the RCP. Near the lower end of the discharge nozzle, three-dimensional swirling flows and flow separation are evident. In the diffuser, the imparity of the velocity profile with respect to different axial cross sections is verified, and the velocity increases gradually from the shroud to the hub. In the casing, velocity distribution is nonuniform over the circumferential direction. Vortices shed consistently from the diffuser blade trailing edge. The experimental results lend sound support for the optimal design of the RCP and provide validation of relevant numerical algorithms.

Effect of Particle Loading Ratio and Orifice Exit Velocity on a Particle-Laden Jet

  • Paik, Kyong-Yup;Yoon, Jung-Soo;Hwang, Jeong-Jae;Chung, Jae-Mook;Bouvet, Nicolas;Yoon, Young-Bin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.3
    • /
    • pp.296-304
    • /
    • 2011
  • In order to design a shear coaxial injector of solid particles with water, basic experiments on a particle laden jet are necessary. The purpose of the present study is to understand the effect of particle loading ratio on the particle spray characteristics (i.e. spreading angle, distribution of particle number density, velocity profiles, and particle developing region length). Hydro-reactive Al2O3 particles with a primary particle diameter of 35~50 ${\mu}m$ are used in this experiment. An automated particle feeder was designed to supply constant particle mass flowrates. Air is used as the carrier gas. To determine the air velocity at the orifice exit, tracers (aluminum oxide, 0.5~2 ${\mu}m$ primary diameter) are also supplied by a tracer feeder. A plain orifice type injector with 3 mm diameter, and 20 mm length was adopted. Particle image velocimetry is used to measure the mean and fluctuating velocity components along the axial and radial directions.

PIV 기법을 이용한 마하 2.0 초음속 노즐의 과대팽창 충격파구조에 대한 연구

  • 김정훈;안규복;김지호;윤영빈
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.64-64
    • /
    • 2002
  • Two dimensional velocity distributions outside a Mach 2.0 supersonic nozzle have been investigated using digital particle image velocimetry (PIV). Mean velocities, turbulence intensities, vorticity field and volume dilatation field are obtained from 300 instantaneous PIV images using 0.33 $\mu\textrm{m}$ $TiO_2$ particle. The seeding particle of larger size, 1.4 $\mu\textrm{m}$ $TiO_2$, is also used for the experimental measurements of velocity lag downstream of shock waves according to particle sizes. The results have been compared and analyzed with schlieren photographs and computational fluid dynamics (CFD) results for the velocity distribution, the locations of shock waves and over-expanded shock structure. It was shown that the locations of normal shock and shock waves can be resolved by the axial or radial velocities, and the velocity lag is more significantly increased due to particle inertia as a particle size increases. And it was also found that over-expanded shock structures call be predicted by volume dilatation fields, and streamwise turbulence intensities are influenced significantly by normal shock waves.

  • PDF

Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow (입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법)

  • Jin Dong-Xu;Lee Dae-Young;Lee Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

Velocity measurements in complex flows of non-Newtonian fluids

  • Muller, Susan J.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.3
    • /
    • pp.93-105
    • /
    • 2002
  • Experimental methods for making quantitative measurements of velocity fields in non-Newtonian fluids are reviewed. Techniques based on light scattering spectroscopy - laser Doppler velocimetry and homodyne light scattering spectroscopy, techniques based on imaging the displacement of markers - including particle image velocimetry and molecular tagging velocimetry, and techniques based on nuclear magnetic resonance imaging are discussed. The special advantages and disadvantages of each method are summarized, and their applications to non-Newtonian flows are briefly reviewed. Example data from each technique are also included.