• 제목/요약/키워드: Particle Collection

검색결과 307건 처리시간 0.028초

에어로졸 시험장비를 이용한 방호 의복 소재의 여과 효율에 대한 연구 (The Experimental Study of SPM(Selectively Permeable Membrane Materials) by using Aerosol Test Instrument)

  • 권태근;서현관;김진원;강재성;강기태;안강호;최진수;조재호;권용택;박현배
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.109-117
    • /
    • 2014
  • In Korea, permeable protection clothes for chemical agent is being developed and distributed. But permeable protection clothes are vulnerable for biological agent of particle type. Therefore selective permeable membranes are being developed to protect chemical agent and biological agent simultaneously. In this study, aerosol collection efficiency test was performed to validate the protection performance of permeable clothes and selective permeable membranes. Aerosol collection efficiency test was performed by using the aerosol test equipment that could test aerosol particle diameter from $0.005{\mu}m$ to $3.0{\mu}m$. This study shows the test method and performance test results for collection efficiency by using the aerosol test equipment.

전기하전식 세정집진장치 개발에 관한 기초 연구 (A Basic Study on Developing an Electrocharged Scrubber)

  • 김종호
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

Experimental Study of Small Cyclones as Particle Concentrators

  • Kim Hyeon-Tae;Y. Zhu;W. C. Hinds;Lee Gyu-Won
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.407-408
    • /
    • 2001
  • This paper describes the effects of varying the minor flow on particle collection efficiency and particle concentration in small cyclones. A cyclone haying a minor flow pumped out from its dust outlet is referred to as a virtual cyclone in this study although the terminology has been used for other types of devices (Torczynski and Rader, 1997). The virtual cyclones tested here have a rectangular inlet and circular outlet similar to the conventional cyclone. (omitted)

  • PDF

사이클론 선회류 약화기 구조에 따른 미세먼지 집진효율 연구 (The Effect of Cyclone Vortex Finder Configurations on the Fine Particle Collection Efficiencies)

  • 정동균;김범석;홍민선
    • 대한환경공학회지
    • /
    • 제39권6호
    • /
    • pp.371-376
    • /
    • 2017
  • 선회류 약화기(vortex finder)의 구조와 치수를 변형한 7종류의 cyclone을 제작해 PM-10 집진효율 자료를 도출하였고 CFD 분석을 통한 사이클론 입구 속도를 계산하였다. 입구속도는 normal, P, A type 사이클론의 경우 15.48 m/sec, 16.03 m/sec 그리고 15.90 m/sec로 계산되었고 PM-10 집진효율 실험결과는 P tpye과 A type의 사이클론의 경우 normal 사이클론에 비해 4%와 7%의 집진효율이 증가하였다. 또한 평행부의 길이가 증가함에 따라 PM-10의 집진효율은 증가하다 감소하여 집진효율을 최대화 할 수 있는 길이가 존재함을 보여주었다.

고내구성 하전 및 집진 방식 전기집진기의 미세입자 제거 특성 (Evaluation of Fine-Particle Removal Performance of Novel ESP with Highly Durable Chargers and Collectors)

  • 김학준;한방우;홍원석;신완호;송동근;정상현;김용진;오원석;황규동;유성연
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.423-428
    • /
    • 2010
  • 반도체 공정에서 배출되는 미세입자를 포집하기 위하여 전기집진장치가 적용되고 있으나, 배출가스 내 포함된 강부식성 오염원에 의한 전기집진장치 내부 오염 및 부식 문제가 심각하여, 이를 해결하기 위한 방안이 절실하다. 본 연구에서는 탄소섬유로 이루어진 하전부와 PET 필름 사이에 금속 박막이 삽입된 집진부로 이루어진 내부식 전기집진장치를 개발하여, 하전부 및 집진부 인가전압, 처리유량, 하전부 채널 수 등의 운전 조건에 따른 전기집진기의 초미세입자 집진 성능을 평가하였다. 평균입경이 100 nm인 KCl 입자를 시험입자로 사용하였으며, 전기집진기 전/후단 입자 농도 변화를 측정하기 위하여 SMPS를 사용하였다. 본 연구에서 개발된 9채널 하전부와 65 mm 집진부로 구성된 전기집진기의 성능평가 결과, $500\;m^3/hr$ 유량조건에서 하전부 및 집진부에 7 kV와 10 kV를 각각 인가하였을 때, 300 nm입자에 대한 포집효율이 90% 이상으로 높게 나타났다.

Theoretical Study on Magnetic Field Application for Fine Particle Capture

  • Huang, Shan;Park, Haewoo;Jo, Youngmin
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.45-51
    • /
    • 2014
  • Fine particle capture is facing a challenge since traditional filtration which relies on the combination of impaction, interception, diffusion has a limited efficiency for fine particle capture particularly in size from 0.1 to $0.5{\mu}m$. This paper reviewed the collection efficiency of above mechanisms, as well as magnetic mechanisms for ferromagnetic particles, and mainly studied the influencing factors of magnetic filtration. Filtration velocity, magnetic field intensity and fiber size were found to be the most important parameters for magnetic filtration.

전기폭발법에서 SMPS를 이용한 Cu 나노분말의 실시간 입자특성평가 (In-situ Particle Characterization of Cu Nanopowder using Scanning Mobility Particle Sizer in Pulsed Wire Evaporation Method)

  • 이창우;맹덕영;박중학;유지훈;이재훈;이창규;김흥회
    • 한국분말재료학회지
    • /
    • 제10권4호
    • /
    • pp.275-280
    • /
    • 2003
  • Synthesis and characteristics of Cu nanopowder were considered by in-situ characterization method using SMPS in pulsed wire evaporation process. With increasing pressure in chamber, particle size and degree of agglomeration increased by increase of collision frequency. Also, it was found from the XRD analyses and BET measurements that crystallite size and particle size decreased with elevating applied voltage. However, SMPS measurements and TEM observation revealed the increase of particle size and degree of agglomeration with increase of applied voltage. These results suggested that particle growth and agglomeration depend on overheating factor in chamber at the early stage and thermal coagulation in filtering system during powder formation until collection.

공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구 (Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners)

  • 김학준;한방우;김용진;차성일
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

자동차용 정전 필터의 미세 입자 포집 특성 (Collection Performance of an Electret Cabin Air Filter for Fine Particles)

  • 지준호;강석훈;김동철;황정호;윤웅섭;배귀남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.85-90
    • /
    • 2001
  • This work presents experimental results of filter media test by using particles from $0.02\;to\;0.6{\mu}m$ in diameter and by applying different charging states. In order to investigate the electret filter performance, the collection efficiency and the pressure drop of filter were measured. The face velocities of test filters varied from 2.4 to 20.4 cm/s. Another experiment setup for the cartridge cabin air filter was used to get an collection efficiency in submicron region. After charging level of electret filter severely decreased, the change of collection efficiency was verified. Experimental results show that the reliability of electret filters can be poor in some conditions.

  • PDF

상부유입식 전기 Cyclone-Bag Filter의 특성 (Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet)

  • 여석준
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF