• Title/Summary/Keyword: Partial volume effect

Search Result 115, Processing Time 0.028 seconds

$CO_2$ Laser Weldablity of High Strength Al Alloy A5038 and A7N01 (고강도 Al합금 A5083 및 A7N01의 $CO_2$ 레이저 용접성)

  • 김장량;하용수;강정윤;김인배
    • Laser Solutions
    • /
    • v.4 no.2
    • /
    • pp.1-12
    • /
    • 2001
  • This study has been performed to evaluate basic characteristics of CW-CO$_2$ laser welding process of A5083 and A7N01 Al alloy. The effect of welding parameters, such as shielding gas, gas flow rate, laser power and welding speed on the bead shape and porosity from bead on plate welding tests have been investigated. Welds shielded by He gas had deeper penetration and better bead shape than those shielded by Ar. The penetration depth was augmented with the increase of laser Power and the decrease of welding speed. Welds of A7N01 alloy had deeper penetration than those of A5083 alloy In beads of A5083 alloy which has deeper penetration, the volume fraction of porosities was high due to the number of its was few, but size of its was larger. The case of deeper penetration beads of A7N01 alloy, the porosity reduced under relatively higher power The Volume fraction of porosities in weld of A5083 alloy was significantly higher than that in weld of A7N01 alloy.

  • PDF

Study of Counter Diffusion in Isostatic Permeameters

  • Bianchi, F.;Pegoraro, M.;Zanderighi, L.
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • The counter-diffusion of two gaseous substances permeating a polymeric membrane has been investigated both experimentally and theoretically. The aim of the study was to find mutual effects, if any, that could influence the permeability and diffusivity data. The experimental data were obtained with an isostatic permeameter operating at ambient pressure and 303 K: helium, nitrogen, carbon dioxide methane were used as permeating gas at different partial pressure; helium or nitrogen as equilibrating or carrier gas. No evident mutual effect of the counter-diffusing gas was observed. The theoretical analysis gave some insight into the phenomena and it was concluded that at near-atmospheric pressures, and in the absence of swelling phenomena no mutual interaction exists. On a theoretical basis any mutual interaction between diffusing and counter-diffusing gases could only occur: i) at high pressures , when the free movement of permeating gas molecules within the polymer is hindered by the counter-diffusing gas; ii) when a large part of the free volume fraction is occupied by the counter--diffusing gas; iii) swelling phenomena modify the structure and free volume fraction of the polymer.

  • PDF

Thermodynamics of 2, N-Dimethyl Pyridinium Iodide in Ethanol-Water Mixture under High Pressure

  • Jee, Jong-Gi;Lee, Young-Hwa;Woo, Eui-Ha;Lee, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.3
    • /
    • pp.115-119
    • /
    • 1983
  • The ionic association constants (K) of 2, N-dimethyl pyridinium iodide (2NDMPI) in 95 volume percentage ethanol-water mixture were determined by a modified UV and conductance method at $20^{\circ}C{\sim}50^{\circ}C$ under 1 to 2000 bars. The K values increase with increasing pressure and decrease with temperature. The total partial molar volume change (${\Delta}V$) has relatively small negative value and the absolute ${\Delta}V$ value decrease with increasing pressure and temperature. The ion size (a) and solvation number (n) of 2NDMPI were about 5 $\AA$ and changed from 1 to 3 with decreasing temperature. Other thermodynamic parameters such as enthalpy (${\Delta}H^{\circ}$) and entropy (${\Delta}S^{\circ}$) for the equilibrium of the 2NDMPI were evaluated. From all the parameters mentioned above, we came to conclusion that the electrostriction effect of 2NDMPI in the ethanol-water mixture is enhanced with increasing pressure and decreasing temperature.

General Pharmacology of DA-8159, a New Pyrazolopyrimidinone Derivative (새로운 피라졸로피리미디논 유도체 DA-8159의 일반약리작용)

  • 오태영;김동환;손문호;김동성;안병옥;김순회;김원배
    • Biomolecules & Therapeutics
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • General pharmacological properties of DA-8159, a new pyrazolopyrimidinone derivative were examined in laboratory animals to investigate its safety profile. The oral administration of DA-8159 (1, 5 or 30 mg/kg) in mice and rats had no effect on general behaviors and central nervous system of the animals in test systems, such as hexobarbital-induced sleeping time, motor coordination, normal body temperature, writhing syndromes induced by 0.75% acetic acid solution, chemo-shock produced by pentetrazole solution and rotar rod test. Anesthetized cats treated intravenously with DA-8159 (0.1, 0.3, 1, 3 or 10 mg/kg) showed transient and mild decrease in blood pressure. However, heart rate, respiration rate and tidal volume were not changed by intravenous DA-8159. In the isolated organs including ileum, heart (sinus rate of atria and contractility of papillary muscle), trachea of guinea pigs and phrenic nerve of rats, DA-8159 ($10^{-8}$$10^{-5}$ mg/L) did not elicit any effect or inhibitory action on the chemically or electrically stimulated contraction. DA-8159 did not influence gastric secretion, pH and total acid output in rats and intestinal propulsion in mice. The administration of DA-8159 in rats had no effect on the platelet aggregation induced by ADP in rabbit plasma, urinary volume and electrolyte ion ($Na^{+}$, $K^{+}$, $Cl^{-}$) excretion in rats. Prothrombin time (PT) of the rats showed a mild but significant increase after administration of DA-8159. Activated partial thromboplastin time (APTT), however, was not affected by DA-8159. These results indicate that DA-8159 does not exert any of serious pharmacological effects.

Removal of Edge Artifact due to Pertial Volume Effect in the Adaptive Template Filtering (적응 템플릿 필터링에서 복셀의 부분 볼륨 효과로 인한 헤지 아티팩트의 제거)

  • 안창범;송영철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.120-127
    • /
    • 2000
  • Adaptive template filtering has been proposed recently for enhancement of signal-to-noise ratio without loss of resolution. In the adaptive template filtering, an optimal template among multiple templates is selected, then linear least square error filtering based on the template is applied in vowel by vowel basis. In some magnetic resonance imaging, where the distribution of gray level has relatively small dynamic range, e.g., $T_1$ imaging, however, artificial stair-like artifact is observed at near edges. This is partially due to the edge enhancement effect in such yokels that contain multiple compounds at the boundaries of tissues. The gray levels of these yokels become similar gray levels of near dominant vowels that contain single compound by the adaptive filtering, which enlarges edge discontinuities. In this paper, we propose a technique to eliminate such artifact by identifying those yokels that contain multiple compounds and assigning the largest template for them. Filtered images with the proposed technique show substantial visual enhancement at the edges without degradation of peak signal-to-noise ratio compared to the original adaptive template filtering for both magnetic resonance images and phantom images.

  • PDF

A Study on the Lap Joint $CO_2$ Laser Welding of Different Gauge Sheets Using ANOVA in Characteristic Zones (특징영역별 분산분석에 의한 이종두께 겹치기 $CO_2$ 레이저 용접에 대한 연구)

  • 이경돈
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.122-128
    • /
    • 2002
  • The laser welding in the automotive industries has been used widely for the butt joint of blank sheets rather than the lap joint of automotive body panels. But as a substitute far the spot welding of automotive body panels, the so called three dimensional laser welding will be important far the body panel engineers. Specially the laser welding of body panels with a smooth weld line is applied increasingly, for example, to the side panels. So far, some criteria of the laser weld quality was suggested by in-house regulations or national standards from experiences and/or rule of thumbs. In the manufacturing places, a go or no-go criterion is adopted because of the simplicity or a lack of rational criteria. It is true specially for the selection of the process parameters, which gives the basic causes for the good quality of laser welds. In this study, the effects of joint combination, gap and welding speed on the lap joint $CO_2$ laser welding of two mild steel sheets with different thicknesses are obtained through a $2{\times}3{\times}7$ factorial experiment. The results of the weld quality are statistically analysed using analysis of variance (ANOVA) and compared between two characteristic zones, which are separated by the type of sectional shapes and the level of input energy per volume. The thickness combinations are 0.8mm/1.2mm, 1.2mm/0.8mm of mild steel sheets. The welding speed covers from the deep penetration to the partial penetration. The gap size has three levels of no-gap, 0.16m, and 0.26mm. The bead width, penetration depth and input energy per volume are measured and used as the weld quality criteria.

Therapeutic Effect of Nocturnal Water Restriction in Children with Primary Nocturnal Enuresis (일차성 야뇨증 아동에서 야간 수분 제한의 치료 효과)

  • Lee Soo Jin;Yang Jae Young;Kim Hae Soon;Lee Seung Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Purpose : Treatment of primary nocturnal enuresis (PNE) includs folk remedies and various treatments based on pathogenesis. We assessed the therapeutic effect of nocturnal water restrict ion as the primary treatment of PNE. Materials and methods : From October 1998 to June 1999, 41 children with PNE (>3 wet nights per week) who visited Ewha Womans University Mokdong hospital and who had good compliances to nocturnal water restriction for 2 months were included. Before and during nocturnal water restriction, daily fluid intake and urine volume were recorded for 2 days every 2 weeks. Responses to nocturnal water restriction were classified according to the decrease of wet nights as complete (>90$\%$), partial (50-90$\%$) and no (<50$\%$) response. Predictors such as age, sex, daytime voiding dysfunction, fluid intake, urine volume, maximum urine volume per void and fasting urine osmolality were evaluated. Results . The response rate to nocturnal water restriction fir 2 month was 82.9$\%$(34/41) [complete response 39.0$\%$(16/41), partial response : 43.9$\%$(18/41)]. The response rate to nocturnal water restriction was significantly higher in monosymptomatic PNE than polysymptomatic PNE and more effective in PNE with or nocturnal fluid intake, nocturnal urine volume, and maximum urine volume than lower nocturnal fluid intake, nocturnal urine volume and maximum urine volume per void (P<0.05). Nocturnal urine volume, maximum urine volume per void and luting urine osmolality after nocturnal water restriction has significantly increased higher in complete response and partial response group than in no response group (P<0.05). Conclusion : The nocturnal water restriction was effective in monosymptomatic PNE with nocturnal polydypsia, nocturnal polyuria and high bladder capacity. (J, Korean Soc Pediatr Nephrol 5 : 51- 8, 2001)

  • PDF

Successful Treatment with Partial Splenic Embolization in a Case of Post-transplantations Lymphoproliferative Disease with Persistent Hypersplenism (림프세포증식성 질환에서 효과를 보인 부분적 비동맥 색전술 1례)

  • Kim, Mi Jin;Rho, Young Il;Yang, Eun Seok;Moon, Kyung Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.92-97
    • /
    • 2004
  • Posttranplantations lymphoproliferative disease (PTLD) is a common and life-threatening complication for soid organ transplantation associated with the use of chronic immunosuppression and Epstein-Barr virus. There is no standardized treatment algorithm, but numerous management strategies are vaiable. Partial splenic embolization (PSE) had been demonstrated to be an effetive alternatie to splenectomy for patients hypersplenism and portal hypertension. PSE has the advantages of non-invasive intervention and resolution of the complications of hypersplenism. We report the effect of the PSE in a 6-year old male liver transplantation recepient with PTLD who has undergone persistent hypersplenism post-transplant. We reduced immunosuppression agent, started antiviral agent. We started with interferon and IV globulin one month after admission. Hepatosplenomegaly and cervical lymphadenopathy were improved. But fever was not subside. We selectively embolized the lower pole of the spleen to achieve a 50~60% reduction in flow as determined by angiography. After embolization, fever subside and peripheral blood findings were improved. Follow up abdominal CT revealed reduced volume of spleen due to ischemic change and there was no multiple enlarged mesenteric lymphnode compared to preembolization state. We thick that PSE is a safe an effetive treatment modality of PTLD with persistent hypersplenism in patients twho failed to medical treatment.

  • PDF

Analytical study on post-buckling and nonlinear free vibration analysis of FG beams resting on nonlinear elastic foundation under thermo-mechanical loadings using VIM

  • Yaghoobi, Hessameddin;Valipour, Mohammad Sadegh;Fereidoon, Abdolhossein;Khoshnevisrad, Pooria
    • Steel and Composite Structures
    • /
    • v.17 no.5
    • /
    • pp.753-776
    • /
    • 2014
  • In this paper, nonlinear vibration and post-buckling analysis of beams made of functionally graded materials (FGMs) resting on nonlinear elastic foundation subjected to thermo-mechanical loading are studied. The thermo-mechanical material properties of the beams are assumed to be graded in the thickness direction according to a simple power law distribution in terms of the volume fractions of the constituents, and to be temperature-dependent. The assumption of a small strain, moderate deformation is used. Based on Euler-Bernoulli beam theory and von-Karman geometric nonlinearity, the integral partial differential equation of motion is derived. Then this PDE problem which has quadratic and cubic nonlinearities is simplified into an ODE problem by using the Galerkin method. Finally, the governing equation is solved analytically using the variational iteration method (VIM). Some new results for the nonlinear natural frequencies and buckling load of the FG beams such as the influences of thermal effect, the effect of vibration amplitude, elastic coefficients of foundation, axial force, end supports and material inhomogenity are presented for future references. Results show that the thermal loading has a significant effect on the vibration and post-buckling response of FG beams.

Volumetric change of the latissimus dorsi muscle after postoperative chemotherapy and radiotherapy in immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap: final results from serial studies

  • Song, Kyeong Ho;Oh, Won Seok;Lee, Jae Woo;Kim, Min Wook;Jeong, Dae Kyun;Bae, Seong Hwan;Kim, Hyun Yul;Jung, Youn Joo;Choo, Ki Seok;Nam, Kyung Jin;Joo, Ji Hyeon;Yun, Mi Sook;Nam, Su Bong
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Background Breast reconstruction using an extended latissimus dorsi (eLD) flap can supplement more volume than reconstruction using various local flaps after partial mastectomy, and it is a valuable surgical method since the reconstruction area is not limited. However, when performing reconstruction, the surgeon should consider latissimus dorsi (LD) volume reduction due to postoperative chemotherapy (POCTx) and postoperative radiotherapy (PORTx). To evaluate the effect of POCTx and PORTx on LD volume reduction, the effects of each therapy-both separately and jointly-need to be demonstrated. The present study quantified LD volume reduction in patients who underwent POCTx and PORTx after receiving breast-conserving surgery (BCS) with an eLD flap. Methods This study included 48 patients who received immediate breast reconstruction using an eLD flap from January 2013 to March 2017, had chest computed tomography (CT) 7-10 days after surgery and 10-14 months after radiotherapy completion, and were observed for more than 3 years postoperatively. One surgeon performed the breast reconstruction procedures, and measurements of breast volume were obtained from axial CT views, using a picture archiving and communication system. A P-value <0.05 was the threshold for statistical significance. Results The average volume reduction of LD at 10-14 months after completing POCTx and PORTx was 64.5% (range, 42.8%-81.4%) in comparison to the volume measured 7-10 days after surgery. This change was statistically significant (P<0.05). Conclusions Based on the findings of this study, when harvesting an eLD flap, surgeons should anticipate an average LD volume reduction of 64.5% if chemotherapy and radiotherapy are scheduled after BCS with an eLD flap.