• 제목/요약/키워드: Partial factor

검색결과 1,139건 처리시간 0.024초

점탄성층이 부분적으로 삽입된 샌드위치보의 횡진동 특성 (Behavior of the Flexural Vibration of a Sandwich Beam with Partially Inserted Viscoelastic Layer)

  • 박진택;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.167-170
    • /
    • 2000
  • The flexural vibration of a sandwich beam with partially inserted viscoelastic layer has been studied using the finite element analysis in combination with an experiment. Effects of length and thickness of partial viscoelastic layers on system loss factor(${\eta}_s$) and resonant frequency(${\omega}_r$) were considerably large. The thicker the viscoelastic layer in a sandwich beam, the larger the system loss factor in Mode 1 as compared with that in Mode 2. The loss factor increased almost linearly with increasing the length of partial viscoelastic layer. Effects of thickness of beams were also considered.

  • PDF

세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement)

  • 김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

3상 고역률 AC/DC 컨버터의 부하에 따른 최적 인덕터값 (Optimal Inductance of Three-phase High-Power Factor Converter)

  • 전중함;김천식;박점문;이석형;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.246-249
    • /
    • 1995
  • This paper proposed a partial resonant swtiching three-phase high power factor converter using a lossless snubber. The proposed converter has a merit of simple controlled circuit because tile input current control discontinuously. And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

배플이 장착된 로켓엔진 연소기의 음향장 해석 (A Numerical Study on Acoustic Behavior in Baffled Combustion Chambers)

  • 손채훈
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.966-975
    • /
    • 2002
  • Acoustic behavior in baffled combustion chambers is numerically investigated by adopting linear acoustic analysis. Partial blade baffle, which is a variant of blade baffle, and hub-blade baffle with six blades are employed as baffle models. Through modal analysis, natural frequencies of each acoustic mode in baffled chambers are calculated and the reduction in natural frequencies caused by baffle installation is examined. Through harmonic analysis, acoustic pressure responses of each chamber to acoustic oscillating excitation are shown. The first tangential mode is found to be most sensitive to acoustic oscillation. Acoustic damping effect of baffle is quantified by damping factor. Damping effect of hub-blade baffle is the most appreciable and damping factor of partial blade baffle is much lower than that of blade baffle. Damping effect of six-blade baflle on the second tangential mode is as much as on the first tangential mode and hub-blade baffle can damp out appreciably the first tangential as well as the first radial mode with the aid of hub.

응력확대계수를 이용한 하중 전달형 필릿 용접부의 피로강도 평가에 관한 연구 (A Study on the Fatigue Life Assessment for Load-carrying Fillet Welded Joints using Stress Intensity Factor)

  • 김명현;강성원;김형래
    • Journal of Welding and Joining
    • /
    • 제26권6호
    • /
    • pp.97-102
    • /
    • 2008
  • It is well known that there exist two typical fatigue crack initiation locations in ship structures: one is the weld toe and the other is the weld root where partial penetration weld is performed. In particular, it is important for fillet weldments to avoid weld root cracking in order to prevent catastrophic failure particularly in ship structures. Therefore detail considerations are required for cruciform joints with partial penetration when there is a possibility of weld root crack initiation. For these reasons, fatigue tests on welded joints were performed in this study. Concept of stress intensity factor(SIF) by means of fracture mechanics is applied for predicting fatigue life of fillet welded joints.

SINGULAR AND DUAL SINGULAR FUNCTIONS FOR PARTIAL DIFFERENTIAL EQUATION WITH AN INPUT FUNCTION IN H1(Ω)

  • Woo, Gyungsoo;Kim, Seokchan
    • East Asian mathematical journal
    • /
    • 제38권5호
    • /
    • pp.603-610
    • /
    • 2022
  • In [6, 7] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities. They consider the Poisson equations with homogeneous boundary conditions, compute the finite element solutions using standard FEM and use the extraction formula to compute the stress intensity factor(s), then they posed new PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor(s), which converges with optimal speed. From the solution they could get an accurate solution just by adding the singular part. They considered a partial differential equation with the input function f ∈ L2(Ω). In this paper we consider a PDE with the input function f ∈ H1(Ω) and find the corresponding singular and dual singular functions. We also induce the corresponding extraction formula which are the basic element for the approach.

부분공진기법에 의한 고효율 인버터 시스템 (High Efficiency Inverter System by Partial Resonant Method)

  • 김영철;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.39-43
    • /
    • 1998
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The switching devices in a proposed circuits are operated with soft switching by the partial resonant method, that is, PRS2MPC (Partial Resonant Soft Switching Mode Power Converter). The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

산소분압의 변화에 따른 ITO/polymeric 박막의 특성 (Characteristics of ITO/polymeric Films with Change of Oxygen Partial Pressure)

  • 신성호;김현후
    • 한국전기전자재료학회논문지
    • /
    • 제17권8호
    • /
    • pp.846-851
    • /
    • 2004
  • Transparent conducting indium tin oxide (TC-ITO) thin films on polymeric substrates have been deposited by a dc reactive magnetron sputtering without heat treatments. The polymeric substrates are acryl (AC), poly carbornate (PC), and polyethlene terephthalate (PET) as well as soda lime glass is also used to compare with the polymeric substrates. Sputtering parameters are an important factor for high quality of TC-ITO thin films prepared on polymeric substrates. Furthermore, the material, electrical and optical properties of as-deposited ITO films are dominated by the ratio of oxygen partial pressure. As the experimental results, the surface roughness of ITO films becomes rough as the oxygen partial pressure increases. The electrical resistivity of as-deposited ITO films decreases initially, and then increases with the increase of oxygen partial pressure. The optical transmittance at visible wavelength for all polymeric substrates is above 82 %.

A case of partial trisomy 3p syndrome with rare clinical manifestations

  • Han, Dong-Hoon;Chang, Ji-Young;Lee, Woo-In;Bae, Chong-Woo
    • Clinical and Experimental Pediatrics
    • /
    • 제55권3호
    • /
    • pp.107-110
    • /
    • 2012
  • Partial trisomy 3p results from either unbalanced translocation or $de$ $novo$ duplication. Common clinical features consist of dysmorphic facial features, congenital heart defects, psychomotor and mental retardation, abnormal muscle tone, and hypoplastic genitalia. In this paper, we report a case of partial trisomy 3p with rare clinical manifestations. A full-term, female newborn was transferred to our clinic. She had cleft lip-plate, dysgenesis of the corpus callosum, patent ductus arteriosus, pulmonary hypertension, and severe right-sided hydronephrosis, associated with ureteropelvic junction obstruction. Cytogenetic investigation revealed partial trisomy 3p; 46,XX,der(4)t(3;4)(p21.1;p16). The karyotype of her father showed a balanced translocation, t(3;4)(p21.1;p16). Therefore, the size of duplication can be an important factor.

보조부분 공진 회로를 이용한 삼상 PWM 인버터의 고조파 제거 (Elimination of harmonics in three-Phase PWM inverter using auxiliary partial resonant circuit)

  • 서기영;이현우;김영문;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.137-140
    • /
    • 1998
  • A new SPWM inverter using three-phase boost converter by auxiliary partial resonant with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the switch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new Partial resonant boost converter achieves zero-voltage switching (ZVS) or zero-current switching (ZCS) for all switch devices without increasing their voltage and current stresses. This paper introduces elimination of low-order harmonics compared with conventional SPWM inverter and SPWM inverter using three-phase boost converter by auxiliary Partial resonant.

  • PDF