• 제목/요약/키워드: Partial discharge pulse

검색결과 145건 처리시간 0.037초

광대역 AE 센서에 의한 유중코로나의 초음파 특성 (Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor)

  • 김인식;이상우;이동인;이광식;김이국
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

전기적 방법을 이용한 전력용 콘덴서 열화특성 연구 (A Study on the Aging Characteristics of Power Capacitors using Electrical Methods)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

안테나로 측정된 부분방전신호의 노이즈제거 관한 연구 (The study on the de-noise for partial discharge signal measured using the antenna)

  • 김영노;김재철;전영재;서인철;배주천;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.404-406
    • /
    • 2001
  • This paper is detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal. It is difficult to identify PD signal using electromagnetic waves detected by antenna. And so we can removed noise of PD signal using wavelet de-noising method.

  • PDF

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

부분방전 펄스파형에 대한 TF Map 적용 가능성애 대한 연구 (A Study on the Applicability of TF Map for the Partial Discharge Pulse Shapes)

  • 김정태;이호근;임윤석;김지홍;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.107-109
    • /
    • 2004
  • It is well known that on-site corona and various noises make severe problems on the PD(partial discharge) measurement. In this paper, for the improvement of the on-site PD measuring performance, the applicability of TF(Time-Frequency) map was investigated. For the purpose, PDs that can be generated from the defect in the power cables as well as corona discharges and ground noises were measured. And through the TF analysis for the measured data, we have tried to distinguish the real PDs, corona discharges and noises. As a result, it is confirmed that the data of PDs can be clustered themselves separable from other data such as corona and noises on the TF map.

  • PDF

유기화합물이 첨가된 LDPE에서의 트리 형상과 부분방전 (Tree Shape and Partial Dishcharge in LDPE Blended with Organic Compounds)

  • 강성화;최한식;신윤식;정득영;임기조;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1130-1133
    • /
    • 1993
  • In this paper, it is discussed the correlation between shape of tree and internal partial discharge in low density polyethylene(LDPE) blended with organic compounds that used to improve the effect of resistance to treeing. Initiation and growing of tree are retarded in specimens blended with organic compounds that comprised radical having large electron affinity, and also discharge magnitude and counts of discharging pulse per unit time in these samples are more than those in others. It is observed that the shape of tree in these samples is bush type, but in case of pure LDPE samples dendrite type.

  • PDF

$SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II) (Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II))

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

신경회로망을 이용한 방전원 인식에 관한 연구 (Recognition of Discharge Sources using Neural Networks)

  • 이우영;강동식;전영갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1540-1542
    • /
    • 1994
  • This paper describes an experimental study of pattern recognition of partial discharge for three different discharge sources by using neural network(NN) system. The NN system is three layer feedforward connections and its learning method is a backpropagation algorithm incorporating an external teacher signal. Input information for NN is a statistical parameters of a discharge magnitude and the number of pulse count. After learning three typical input patterns, NN system offers good discrimination between different defects.

  • PDF