SWNT-UHF Fusion Sensor for GIS Partial Discharge Detection (가스절연기기의 부분방전검출을 위한 SWNT-UHF 융합센서)

  • Lee, Sang-Wook;Chang, Yong-Moo;Baik, Seung-Hyun;Lee, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.120-120
    • /
    • 2010
  • To detect the PD events, we have studied a fusion sensor, the UHF sensor and the single-walled carbon nanotube(SWNT) gas sensor. We are accustomed to the UHF sensor which have employed to detect the partial discharges in apparatus GIS-like. But the SWNT gas sense is a newly way proposed to detect the partial discharges. In this study, we monitored not only the changes of the electrical conductance of the SWNT sensors in responding to the PD events but also the signal of the UHF sensor at the same time with IEC 60270 standard method for reference on the partial discharge events.

  • PDF

A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable (고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구)

  • Song Jae-Yong;Seo Hwang-Dong;Park Dae-Won;Kil Gyung-Suk;Han Moon-Sup;Jang Dong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.

A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials (장시간 절연체 열화실험을 위한 부분방전측정기술 연구)

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

A Study on the Signal Propagation Characteristics of Generator Windings (발전기 권선에서의 신호전송 특성에 관한 연구)

  • Hwang, Don-Ha;Kim, Jin-Bong;Kim, Yong-Joo;Park, Myong-Soo;Kim, Taek-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF

Korean Institute of Electrical and Electronic Materials (XLPE 전력케이블의 부분방전 측정을 위한 평면 루프 센서 설계에 관한 연구)

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Lwin, Kyaw-Soe;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.27-31
    • /
    • 2008
  • In this study, The new type of loop antenna which detects the partial discharge was designed based on microstrip line technology. In diagnosis of power cable, partial discharge signal generally occurred at the frequency range lower than 100MHz because high frequency PD signals could be lost along the propagation path in the cable. The new type of loop antenna sensor has been studied by using Simulation software named CST microwave studio version 5.0. In partial discharge measuring experiments, commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT sensor and loop antenna sensor in detection partial discharge on MV XLPE cable of 22.9kV. In this study, we have shown our loop antenna sensor can apply as a commercial HFCT sensor.

  • PDF

A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map) (PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구)

  • Kim, Ji-Hong;Kim, Jeung-Tae;Kim, Jin-Gi;Koo, Ja-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

A Study of Narrow Band Radio Electro-Magnetic Wave Measurement for Detection of Partial Discharge (부분방전 탐지를 위한 협대역 방사전자파 측정에 관한 연구)

  • Yoon, D.H.;Park, K.S.;Kim, K.C.;Lee, K.S.;Joo, J.H.;Kim, L.K.;Park, C.K.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1748-1750
    • /
    • 2002
  • Partial discharge is attendant physical phenomenon on electromagnetic, sounds, lightning and mechanical vibration. In this paper, we simulated GIS and measured the radiated electromagnetic wave emitted from partial discharge in $SF_6$ gas using antenna(30[MHz] ${\sim}$ 2[GHz]) and spectrum analyzer. This paper describes characteristics of radiated electromagnetic waves with distance 1 [m] between antenna and discharge source.

  • PDF

PD Measurement in oil with defects (결함별 절연유중 부분방전 측정 연구)

  • Sun, J.H.;Yi, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.67-69
    • /
    • 2004
  • Since partial discharges in power transformers weaken their insulation performance the detection of partial discharge is very important for prevention of fatal incidents. This study describes use of electromagnetic coupler for measurement of partial discharge of transformers. Spiral antennas of which bandwidth is 0.5GHz to 3GHz were used as coupler and setup in chamber for partial discharge tests. Test results showed that outputamplitudes are increased with PD increase and frequencies of signal measured by these antennas are mostly distributed below about 800MHz.

  • PDF

A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge (부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구)

  • Kim, Ji-Hong;Koo, Ja-Yoon;Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.