• Title/Summary/Keyword: Partial discharge detection

Search Result 196, Processing Time 0.031 seconds

Detection of partial Discharge in the Metal Clad Switchgear Using the Electromagnetic Technique (전자파 측정기법을 이용한 폐쇄 배전반내 부분방전 검출)

  • Seo, In-Chul;Kim, Jae-Chul;Kim, Young-No;Jeon, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.403-405
    • /
    • 2001
  • This paper presents the detection method of partial discharge in metal clad switchgear(MCS) using electromagnetic technique. Two antennas are located in the inside and outside of the MCS, and electromagnetic waves detected by these antennas are analyzed and compared by FFT method in order to identify an insulation abnormality. As a result of the experiment by the proposed method, we show the detection possibility for partial discharge in the MCS. The proposed method is expected to apply to insulation condition observation and an accident prevention in the MCS effectively.

  • PDF

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

Characteristics of AE Sensor for Detection of Metallic particle in GIS (가스절연개체장치의 금속이물 탐지용 AE 센서의 특성)

  • 홍재일;민석규;정영호;류주현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.286-289
    • /
    • 1999
  • In order to detect the partial discharge with the metallic particle in GIS, AE sensor was designed and simulated by ANSYS, and manufactured as the coupled vibration mode. The resonant frequency of three Coupled AE sensors were as follows ; 147.88 kHz in 8.1 mm$\Phi$ $\times$ 8.1mm, 128.82 kHz in 9.5 mm$\Phi$ $\times$ 9.5mm, 85.22 kHz in 14.3mm$\Phi$ $\times$14.3mm. That frequency is λ/2 resonant frequency. AE sensor of 9.5mm$\Phi$ $\times$9.5mm responded higher than the other coupled vibration mode AE sensor at the partial discharge detection in GIS.

  • PDF

Implementation for Partial Discharge Detection using Ultrasonic Signal (초음파 신호를 이용한 부분방전 검출 장치 개발에 관한 연구)

  • Choi, S.A.;Chung, H.H.;Kwak, H.R.;Kim, J.C.;Chung, S.J.;Yoon, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.588-590
    • /
    • 1993
  • This paper presents a diagnostic technique using ultrasonic for operating power transformer. Two methods are used as a base for detecting a partial discharge. One is a analysis of PD trend using counted ultrasonic signal, the other is a estimation of PD location source using cross-correlation. In this paper we implement detection equipment of partial discharge in power transformer. The desired system is utilized to two methods for PD detection and operated by graphical user interface(GUI). The results of test showed that the system can be adopted to real power transformer.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number (超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診)

  • 권동진;곽희로;정상진;김정부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

Using the TDR in Dielectric for Partial Discharge Signals Detection Method (이종 비유전율에서 TDR을 이용한 PD발생 위치 추적방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1374-1379
    • /
    • 2015
  • Time Domain Reflectometry(TDR) using microwave bands, including broadband spectrum that occurs at the range of rates that start between partial discharge position it easier to make the techniques that could be measured. Partial discharge in the Gas Insulated Switchgear(GIS), the dielectric constant in the band more than GHz different the insulating material if you want to organize, and the insulating material regardless of how partial discharge position in the SF6 gas Partial Discharge by applying the heritability estimated its position, but the position error occurred about 23 percent of the existing way, correct in not suitable location tracking the outbreak PD. This technique the rate of other dielectric that make up the power apparatus heterology is measured at the function to slow the progression of the electromagnetic waves apart by calculating the partial discharge as the location, A simple way to track. Dielectric using other methods proposed new structure can calculate the speed of heritability PD is occurring can measure.

Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing (분포형 광음향센싱 기반 부분방전 모니터링 기술 연구)

  • Huioon, Kim;Joo-young, Lee;Hyoyoung, Jung;Young Ho, Kim;Myoung Jin, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.

Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave (방사전자파를 이용한 고분자애자의 오손량 분류기법)

  • Park Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.